Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
BMC Infect Dis ; 21(1): 481, 2021 May 26.
Article in English | MEDLINE | ID: mdl-34039295

ABSTRACT

BACKGROUND: The coronavirus disease 2019 (COVID-19) epidemic has been largely controlled in China, to the point where case fatality rate (CFR) data can be comprehensively evaluated. METHODS: Data on confirmed patients, with a final outcome reported as of 29 March 2020, were obtained from official websites and other internet sources. The hospitalized CFR (HCFR) was estimated, epidemiological features described, and risk factors for a fatal outcome identified. RESULTS: The overall HCFR in China was estimated to be 4.6% (95% CI 4.5-4.8%, P < 0.001). It increased with age and was higher in males than females. Although the highest HCFR observed was in male patients ≥70 years old, the relative risks for death outcome by sex varied across age groups, and the greatest HCFR risk ratio for males vs. females was shown in the age group of 50-60 years, higher than age groups of 60-70 and ≥ 70 years. Differential age/sex HCFR patterns across geographical regions were found: the age effect on HCFR was greater in other provinces outside Hubei than in Wuhan. An effect of longer interval from symptom onset to admission was only observed outside Hubei, not in Wuhan. By performing multivariate analysis and survival analysis, the higher HCFR was associated with older age (both P < 0.001), and male sex (both P < 0.001). Only in regions outside Hubei, longer interval from symptom onset to admission, were associated with higher HCFR. CONCLUSIONS: This up-to-date and comprehensive picture of COVID-19 HCFR and its drivers will help healthcare givers target limited medical resources to patients with high risk of fatality.


Subject(s)
COVID-19/epidemiology , COVID-19/mortality , Hospital Mortality , Hospitalization , SARS-CoV-2 , Adult , Age Factors , Aged , China/epidemiology , Female , Humans , Male , Middle Aged , Risk Factors , Sex Factors , Time-to-Treatment
2.
Appl Opt ; 56(9): D72-D78, 2017 Mar 20.
Article in English | MEDLINE | ID: mdl-28375374

ABSTRACT

A two-dimensional (2D) scatter plot method based on the 2D hyperspectral correlation spectrum is proposed to detect diluted blood, bile, and feces from the cecum and duodenum on chicken carcasses. First, from the collected hyperspectral data, a set of uncontaminated regions of interest (ROIs) and four sets of contaminated ROIs were selected, whose average spectra were treated as the original spectrum and influenced spectra, respectively. Then, the difference spectra were obtained and used to conduct correlation analysis, from which the 2D hyperspectral correlation spectrum was constructed using the analogy method of 2D IR correlation spectroscopy. Two maximum auto-peaks and a pair of cross peaks appeared at 656 and 474 nm. Therefore, 656 and 474 nm were selected as the characteristic bands because they were most sensitive to the spectral change induced by the contaminants. The 2D scatter plots of the contaminants, clean skin, and background in the 474- and 656-nm space were used to distinguish the contaminants from the clean skin and background. The threshold values of the 474- and 656-nm bands were determined by receiver operating characteristic (ROC) analysis. According to the ROC results, a pixel whose relative reflectance at 656 nm was greater than 0.5 and relative reflectance at 474 nm was lower than 0.3 was judged as a contaminated pixel. A region with more than 50 pixels identified was marked in the detection graph. This detection method achieved a recognition rate of up to 95.03% at the region level and 31.84% at the pixel level. The false-positive rate was only 0.82% at the pixel level. The results of this study confirm that the 2D scatter plot method based on the 2D hyperspectral correlation spectrum is an effective method for detecting diluted contaminants on chicken carcasses.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(4): 978-80, 2016 Apr.
Article in Chinese | MEDLINE | ID: mdl-30052362

ABSTRACT

A new analytical method of analyzing dimethyl ether (DME) content in liquefied petroleum gas (LPG) is proposed in this paper. An unsolved problem about quick detection of the composition of LPG has been settled with this method. A set of precise preparation apparatus for DME/ LPG solution and a set of quickly analytical system of LPG based on near infrared technology were designed. The analytical equipment can be conveniently connected to the sampling cylinder because it can bear 3.5 MPa pressure. Oblique projection algorithm was used to separate the pure spectra of DME from that of the LPG's solutions. The standard curve of the concentration of DME (c) has been built by using the Intensity (I) of pure signal of DME in the LPG solution and the concentrations. The correlation coefficient of the equation is 0.999 4. The result of external validation shows that the relative error is less than 2.0%. The new method has the advantages such as fast, easy and noneed of expensive multivariate modeling.

SELECTION OF CITATIONS
SEARCH DETAIL
...