Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Colloids Surf B Biointerfaces ; 235: 113759, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38280240

ABSTRACT

Polysaccharides, with the abundant availability, biodegradability, and inherent safety, offer a vast array of promising applications. Leveraging the remarkable attributes of polysaccharides, biomimetic and multifunctional hydrogels have emerged as a compelling avenue for efficacious wound dressing. The gels emulate the innate extracellular biomatrix as well as foster cellular proliferation. The distinctive structural compositions and profusion of functional groups within polysaccharides confer excellent physical/chemical traits as well as distinct restorative involvements. Gels crafted from polysaccharide matrixes serve as a robust defense against bacterial threats, effectively shielding wounds from harm. This comprehensive review delves into wound physiology, accentuating the significance of numerous polysaccharide-based gels in the wound healing context. The discourse encompasses an exploration of polysaccharide hydrogels tailored for diverse wound types, along with an examination of various therapeutic agents encapsulated within hydrogels to facilitate wound repair, incorporating recent patent developments. Within the scope of this manuscript, the perspective of these captivating gels for promoting optimal healing of wounds is vividly depicted. Nevertheless, the pursuit of knowledge remains ongoing, as further research is warranted to bioengineer progressive polysaccharide gels imbued with adaptable features. Such endeavors hold the promise of unlocking substantial potential within the realm of wound healing, propelling us toward multifaceted and sophisticated solutions.


Subject(s)
Polysaccharides , Wound Healing , Polysaccharides/pharmacology , Polysaccharides/chemistry , Hydrogels/pharmacology , Hydrogels/chemistry , Cell Proliferation , Biomimetics , Anti-Bacterial Agents/pharmacology
2.
J Orthop Translat ; 24: 144-149, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33101964

ABSTRACT

OBJECTIVE: This study hypothesized that the suture anchor of tibial fixation method of PMMR repair technique is the main factor which reduce the gap formation or over displacement of tear site in initial healing, and then investigated the fixation stability of 4 different tibial fixations through cyclic and ultimate failure load testing of meniscal root sutures. METHODS: Twenty-four porcine tibiae with intact medial meniscus roots were randomly assigned into 4 groups: transosseous suture, washer, suture anchor, or screw with washer. Each sample underwent cyclic loading followed by a load-to-failure test. Displacement, maximum load to failure, stiffness, and elongation at failure load were recorded. RESULTS: The maximum average load and displacement at failure for each of the repair groups were as follows: transosseous suture, 232.8 N and 12.16 mm; washer, 189.9 N and 21.5 mm; suture anchor, 140.6 N and 13.8 mm; and screw with washer, 167.9 N and 18.9 mm. The maximum stiffness values for each of the repair groups were as follows: transosseous suture, 19.5 ± 0.7 N/mm; washer, 21.5 ± 1.4 N/mm; suture anchor, 13.8 ± 0.7 N/mm; and screw with washer, 18.9 ± 3.9 N/mm. The mean elongation across the repairs for each of the repair groups after 1000 loading cycles was: transosseous suture, 3.74 ± 0.28 mm; washer, 3.04 ± 0.13 mm; suture anchor, 2.25 ± 0.33 mm; and screw with washer, 2.43 ± 0.19 mm. The mean elongation was significantly less with the suture anchor than with the other techniques (p < .05). CONCLUSION: Under physiological loading, our results indicate that a slower rehabilitation program with limited flexion and only partial weight bearing is advised when using a suture anchor because of the lower maximum load and stiffness. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Tibial fixation using a washer or a screw with a washer is an effective and cost-saving technique when an option is required with high stiffness and low displacement at failure.

3.
BMC Musculoskelet Disord ; 21(1): 697, 2020 Oct 21.
Article in English | MEDLINE | ID: mdl-33087086

ABSTRACT

BACKGROUND: Vascular injury is a very rare complication following arthroscopic knee surgery. This is the first report of pseudoaneurysm at the saphenous branch of the descending genicular artery complicating semitendinosus tendon harvest in arthroscopic anterior cruciate ligament reconstruction. CASE PRESENTATION: A 19-year-old male had developed large ecchymosis, focal swelling and tenderness around his posteromedial knee after an arthroscopic anterior cruciate ligament reconstruction. Compartment syndrome of the lower leg and deep vein thrombosis were ruled out. A pseudoaneurysm formation was confirmed through an angiography and coil embolization was performed. At one year follow up, the patient reported improved functional outcome with good stability of the knee. However, mild paresthesia over the posteromedial calf was noted due to the compression injury of the saphenous nerve by the hematoma. CONCLUSIONS: The pseudoaneurysm was presumed to result from accidental vascular injury while dissecting the accessory bands of the semitendinosus and was successfully treated by coil embolization. Care must be taken to section the expansions of the hamstring tendon, especially when the patient presents with underlying coagulopathy or vascular disease.


Subject(s)
Aneurysm, False , Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Hamstring Tendons , Adult , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/surgery , Anterior Cruciate Ligament Injuries/diagnostic imaging , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/adverse effects , Hamstring Tendons/diagnostic imaging , Humans , Knee Joint , Male , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...