Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Int J Ophthalmol ; 17(4): 761-766, 2024.
Article in English | MEDLINE | ID: mdl-38638243

ABSTRACT

AIM: To evaluate scleral buckling (SB) surgery using a non-contact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil (SO)-filled eyes. METHODS: Totally 9 patients (9 eyes) with retinal detachment in SO-filled eyes were retrospectively analyzed. All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination. SO was removed at an appropriate time based on recovery. The patients were followed up for at least 3mo after SO removal. Retinal reattachment, complications, visual acuity and intraocular pressure (IOP) before and after surgery were observed. RESULTS: Patients were followed up for a mean of 8.22mo (3-22mo) after SO removal. All patients had retinal reattachment. At the final follow-up, visual acuity showed improvement for 8 patients, and no change for 1 patient. The IOP was high in 3 patients before surgery, but it stabilized after treatment; it was not affected in the other patients. None of the patients had infections, hemorrhage, anterior ischemia, or any other complication. CONCLUSION: This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.

2.
Int J Ophthalmol ; 14(8): 1205-1212, 2021.
Article in English | MEDLINE | ID: mdl-34414085

ABSTRACT

AIM: To analyse macular microvascular alterations in myopic choroidal neovascularization (mCNV) and the efficiency of anti-vascular endothelial growth factor (anti-VEGF) therapy for mCNV by optical coherence tomography angiography (OCTA). METHODS: A total of 123 patients were included in this retrospective study, divided into mCNV group, high myopia (HM) group, and normal group at the Affiliated Eye Hospital of Wenzhou Medical University from January 2017 to January 2019. Superficial vessel density, deep capillary density, foveal avascular zone (FAZ) area, A-circularity index (AI) and vessel density around the 300 µm width of the FAZ region density (FD) and the area of choroidal neovascularization (CNV) lesion (only for mCNV group) were measured on 3×3 mm2 OCTA images. FAZ area was corrected for axial length. Central macular thickness (CMT) was measured on OCT in mCNV group. Compared the parameters on OCTA of 3 groups and pre-anti-VEGF and post-anti-VEGF at 1, 2, 3, and 6mo follow-up in mCNV group. RESULTS: There were significant differences among 3 groups in superficial vessel density, deep capillary density and FD (P<0.05). FAZ area in HM group was smaller than normal group (P<0.05), but there was no significant difference between mCNV group and the other two group. AI increased in mCNV group (P<0.05). The mean CMT, area and flow area of CNV lesion decreased after treatment (P<0.05), while vessel density and FAZ didn't change. The mean CMT, area and flow area of CNV lesion statistically decreased after anti-VEGF treatment in mCNV group (P<0.05), while superficial vessel density, deep capillary density and FAZ area, AI and FD didn't change. The mean reduction ratio of lesions was 50.32% (7.07% to 100%). Lesion regression 100% was observed in 2 cases (4.88%). There was a negative correlation between the CNV lesion area and reduction ratio (r=-0.380, P=0.042) and the flow lesion area and reduction ratio (r=-0.402, P=0.030). CONCLUSION: Macular vessel density decreases, FAZ turns smaller and more irregular in mCNV eyes. Anti-VEGF therapy is efficient for mCNV without affecting vessel density and FAZ, but it is unable to completely eliminate CNV lesions in most cases. The bigger mCNV lesions have lower reduction ratio.

3.
Hu Li Za Zhi ; 55(5): 56-63, 2008 Oct.
Article in Chinese | MEDLINE | ID: mdl-18836975

ABSTRACT

About 8,000 people die every year in Taiwan as a result of nosocomial infection. Clinically, there is a high possibility for patients to contract nosocomial infection if medical equipment is not completely sterilized. In order to provide care and safety to patients in the operating room, increase management effectiveness and efficiency, and to reduce equipment operating costs, a project was developed to improve operating room management through data collection and analysis. A computerized barcode operational system for packages of surgical instruments was developed and executed throughout an entire operating room. The results showed that average time spent searching for surgical instruments decreased by 2,872 minutes (47.8hrs/month), 150% of the target figure; computerized monitoring of equipment expiration dates reduced total cost by 29.2% abnormal recognition of equipment tags was reduced to 0%. This project is the first one of its kind in the world.


Subject(s)
Electronic Data Processing/methods , Operating Rooms/organization & administration , Surgical Instruments , Operating Rooms/economics , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...