Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Colloid Interface Sci ; 668: 646-657, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38696992

ABSTRACT

Severe spinal cord injury (SCI) leads to dysregulated neuroinflammation and cell apoptosis, resulting in axonal die-back and the loss of neuroelectric signal transmission. While biocompatible hydrogels are commonly used in SCI repair, they lack the capacity to support neuroelectric transmission. To overcome this limitation, we developed an injectable silk fibroin/ionic liquid (SFMA@IL) conductive hydrogel to assist neuroelectric signal transmission after SCI in this study. The hydrogel can form rapidly in situ under ultraviolet (UV) light. The mechanical supporting and neuro-regenerating properties are provided by silk fibroin (SF), while the conductive capability is provided by the designed ionic liquid (IL). SFMA@IL showed attractive features for SCI repair, such as anti-swelling, conductivity, and injectability. In vivo, SFMA@IL hydrogel used in rats with complete transection injuries was found to remodel the microenvironment, reduce inflammation, and facilitate neuro-fiber outgrowth. The hydrogel also led to a notable decrease in cell apoptosis and the achievement of scar-free wound healing, which saved 45.6 ± 10.8 % of spinal cord tissue in SFMA@IL grafting. Electrophysiological studies in rats with complete transection SCI confirmed SFMA@IL's ability to support sensory neuroelectric transmission, providing strong evidence for its signal transmission function. These findings provide new insights for the development of effective SCI treatments.


Subject(s)
Electric Conductivity , Fibroins , Hydrogels , Rats, Sprague-Dawley , Spinal Cord Injuries , Spinal Cord Injuries/drug therapy , Spinal Cord Injuries/physiopathology , Spinal Cord Injuries/pathology , Animals , Rats , Hydrogels/chemistry , Hydrogels/pharmacology , Fibroins/chemistry , Fibroins/pharmacology , Injections , Apoptosis/drug effects , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Particle Size
2.
Adv Biol (Weinh) ; 7(10): e2300098, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37085744

ABSTRACT

Though the occurrence of neuroinflammation after spinal cord injury (SCI) is essential for antigen clearance and tissue repair, excessive inflammation results in cell death and axon dieback. The effect of anti-inflammatory medicine used in clinical treatment remains debatable owing to the inappropriate therapeutic schedule that does not align with the biological process of immune reaction. A better understanding of the immunity process is critical to promote effective anti-inflammatory therapeutics. However, cellular heterogeneity, which results in complex cellular functions, is a major challenge. This study performs single-cell RNA sequencing by profiling the tissue proximity to the injury site at different time points after SCI. Depending on the analysis of single-cell data and histochemistry observation, an appropriate time window for anti-inflammatory medicine treatment is proposed. This work also verifies the mechanism of typical anti-inflammatory medicine methylprednisolone sodium succinate (MPSS), which is found attributable to the activation inhibition of cells with pro-inflammatory phenotype through the downregulation of pathways such as TNF, IL2, and MIF. These pathways can also be provided as targets for anti-inflammatory treatment. Collectively, this work provides a therapeutic schedule of 1-3 dpi (days post injury) to argue against classical early pulse therapy and provides some pathways for target therapy in the future.

3.
Environ Res ; 226: 115702, 2023 06 01.
Article in English | MEDLINE | ID: mdl-36931372

ABSTRACT

The accurate determination of waster sludge water content is crucial to sludge dewatering treatment and its disposal management. Though previous studies highlight the great advantages of low-field nuclear magnetic resonance (LF-NMR) in the determination of sludge water content, its accuracy and applicability are not well studied. Herein, this study investigated the settling of operating parameters and the properties of sludge samples on the accuracy and applicability of LF-NMR method in measuring sludge water content. The results showed that the setting of basic parameters such as standard curve, number of scanning times (NS) and sample weight affected the accuracy of sludge water content by LF-NMR. The standard calibration curve constructed by 3 g/L CuSO4, NS = 8 and the sample weight of about 5 g, were suitable for the accurate determination of sludge water content. Furthermore, the existence of magnetic substances in sludge can affect the distribution gradient of main magnetic field, and thus restricted the applicability of LF-NMR. The saturation magnetization of chemical reagents strongly correlated with the measured relative errors of sludge water content (r = 0.995, p < 0.01), the greater the saturation magnetization of the magnetic material, the greater the error of the test results. On the whole, it is necessary to fully consider the influence of process parameters and sludge properties to evaluate the accuracy and applicability of the LF-NMR method, rather than simply copying the parameters in literatures.


Subject(s)
Sewage , Wastewater , Waste Disposal, Fluid/methods , Water/chemistry , Magnetic Resonance Spectroscopy
SELECTION OF CITATIONS
SEARCH DETAIL
...