1.
Langmuir ; 39(8): 3151-3161, 2023 02 28.
Article in English | MEDLINE | ID: mdl-36791311

ABSTRACT

Harmful particles such as heavy metal particles in the human body can cause many problems such as kidney stones, gallstones, and cerebrovascular diseases. Therefore, it is critical to separate them from the blood and perform a systematic analysis as early as possible. Here, we apply eutectic gallium indium (EGaIn) microparticles as a model to study the separation of particles from blood, thanks to their properties of low toxicity, excellent degradability, and negligible vapor pressure. In particular, the dielectrophoresis (DEP) separation method is employed to separate EGaIn of different sizes and characteristics in blood. First, the screen-printing method is used to create EGaIn microparticles with diameters of 15, 23, 18, and 11 µm. According to the lifetime test, these microparticles can last more than 1 month, as evidenced by their surface oxidation characteristics. Moreover, a DEP platform with W-type electrodes is developed to sort EGaIn particles from whole human blood. The results show that a sorting efficiency of 95% can be attained, which is similar to the separation efficiency of 98% achieved by finite element analysis (FEA) using COMSOL software based on the orthogonal array experiment method. The proposed study successfully validates the use of the DEP method to separate particles from human blood, providing insights into heavy metal particle separating, drug screening, and cell sorting and potentially broadening the applications in environmental analysis, food engineering, and bioengineering.


Subject(s)
Gallium , Indium , Humans , Electrophoresis/methods , Electrodes , Cell Separation/methods
2.
Front Bioeng Biotechnol ; 11: 1308725, 2023.
Article in English | MEDLINE | ID: mdl-38169725

ABSTRACT

Introduction: Pregnanediol-3-glucuronide (PdG), as the main metabolite of progesterone in urine, plays a significant role in the prediction of ovulation, threatened abortion, and menstrual cycle maintenance. Methods: To achieve a rapid and sensitive assay, we have designed a competitive model-based time-resolved fluorescence microsphere-lateral flow immunochromatography (TRFM-LFIA) strip. Results: The optimized TRFM-LFIA strip exhibited a wonderful response to PdG over the range of 30-2,000 ng/mL, the corresponding limit of detection (LOD) was calculated as low as 8.39 ng/mL. More importantly, the TRFM-LFIA strip was innovatively used for the quantitative detection of PdG in urine sample, and excellent recovery results were also obtained, ranging from 97.39% to 112.64%. Discussion: The TRFMLFIA strip possessed robust sensitivity and selectivity in the determination of PdG, indicating the great potential of being powerful tools in the biomedical and diagnosis region.

3.
ACS Omega ; 7(29): 25140-25151, 2022 Jul 26.
Article in English | MEDLINE | ID: mdl-35910182

ABSTRACT

Microparticle manipulation has been widely used in clinical diagnosis, cell separation, and biochemical analysis via optics, electronics, magnetics, or acoustic wave driving. Among them, the bulk acoustic wave (BAW) driving method has been increasingly adopted because of non-contact, easy control, and precise manipulation. However, its low manipulation efficiency limits the usage of the BAW driving in high viscosity solutions. Therefore, in order to obtain larger driving force and more flexible manipulation of microparticles, both two-dimensional (2D) and three-dimensional (3D) platforms based on the BAW and liquid crystal backflow effect (LCBE) driving in liquid crystal (LC) solutions are proposed. The driving forces applied on the microparticles allow for the change of microparticle moving direction, which is also ascertained through theory analysis combined with various driving methods. Specifically, the maximum moving speed (68.78 µm/s) of the polystyrene particles is obtained by the BAW (13 Vpp) combined with LCBE (30 V) at a low frequency of 7.2 kHz in the 2D platform. Precise position manipulation in 3D is also fulfilled through a programmable logic control model using polystyrene particles as a demonstration. In addition, red blood cells mixed with LC solutions are arranged in a line or gathered in the pressure nodes of the BAW forces along with sinusoid signals generated by various transducer combinations. Therefore, it is approved that the LC solution that induces the LCBE force could increase the microparticle manipulation efficiency in both 2D and 3D platforms. The proposed method will open up new avenues in particle manipulation and benefit a variety of applications in cell separation, drug synthesis, analytical chemistry, and others.