Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Front Pharmacol ; 15: 1324892, 2024.
Article in English | MEDLINE | ID: mdl-38487164

ABSTRACT

As an inflammatory disease with a disrupted immune system, cytokine disorders in atopic dermatitis (AD) are closely related to the abnormal activation of JAK-STAT signal pathway. The critical relevance of the JAK-STAT signaling pathway to the pathogenesis of AD provides a strong rationale for JAK inhibitor research. Baricitinib, a small-molecule oral JAK inhibitor, has been proven to inhibit JAK-STAT signaling in a variety of diseases, including AD. It is currently available in China for off-label use. However, its efficacy in China and its mechanism are rarely reported. In our study, we found that the immune status of patients with moderate and severe AD was hyperactive. Among the 49 known immunotherapy targets, JAK1 and JAK2 genes on lymphocytes of AD patients were significantly upregulated, which was closely related to the symptom severity in moderate and severe AD patients. Baricitinib can improve immune hyperresponsiveness and clinical symptoms in moderate and severe AD by inhibiting the activation of Th2 cell subsets and the secretion of Th2-type cytokines through MAPK, mTOR and PI3K-Akt signaling pathways, providing an important theoretical basis for clinical off-label use of Baricitinib to treat moderate and severe AD.

2.
J Glaucoma ; 31(7): 602-608, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35763682

ABSTRACT

PURPOSE: The aim was to evaluate the repeatability and agreement of two swept-source optical coherence tomographers for anterior segment parameters in healthy subjects. PATIENTS AND METHODS: Automated mark of scleral spur and angle recess for the CASIA2 and manual mark of scleral spur and angle recess for the Anterion were performed, and then the measurement values of the related parameters were automatically generated. Subjects with pupil diameter (PD) differing by <15% between the 2 devices were included. PD, lens vault (LV), anterior chamber depth (ACD), angle to angle distance (ATA), anterior chamber width (ACW), anterior chamber angle (ACA), angle opening distance (AOD), and trabecular iris space area (TISA) were measured in the horizontal images with both CASIA2 and Anterion. Intraclass correlation coefficient (ICC) was used to evaluate intradevice repeatability. Bland-Altman plots were performed to assess the agreement between the 2 devices. RESULTS: Thirty-five right eyes of 35 subjects were included with a mean age of 25.60±3.00 years. The CASIA2 showed moderate to good intradevice repeatability (ICCs ranged from 0.786 to 0.989) whereas the Anterion showed good intradevice repeatability (ICCs ranged from 0.921 to 0.998) for anterior segment parameters. Compared with the CASIA2, the Anterion offered larger values of ACA500/750, AOD500/750, and TISA500/750 but smaller values of PD, LV, ACD, ATA, and ACW. Good agreement for PD, ACD, ATA, and ACW was detected with 95% limits of agreement of -1.02 to 1.02 mm, -0.11 to 0.14 mm, -0.17 to 0.19 mm, -0.13 to 0.28 mm, respectively. Poor agreement for LV, ACA500/750, AOD500/750, and TISA500/750 was achieved with the 2 devices. CONCLUSIONS: Anterion outperformed CASIA2 on intradevice repeatability. While agreement was noted for some parameters using manual Anterion and automated CASIA2 approaches, poor agreement of LV and angle parameters indicates that measurements from these optical coherence tomography devices should not be considered interchangeable.


Subject(s)
Anterior Eye Segment , Intraocular Pressure , Adult , Anterior Chamber/diagnostic imaging , Anterior Eye Segment/diagnostic imaging , Humans , Iris/diagnostic imaging , Tomography, Optical Coherence/methods , Young Adult
3.
Graefes Arch Clin Exp Ophthalmol ; 260(7): 2271-2281, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35171331

ABSTRACT

PURPOSE: To investigate the repeatability of Anterion and compare the agreement of ocular biometric measurements and predicted intraocular lens (IOL) powers with other three optical biometers. METHODS: Flat keratometry (Kf), steep keratometry (Ks), J0 and 45 vectors, central cornea thickness (CCT), anterior chamber depth (ACD), and axial length (AL) from the Anterion, IOLMaster 700, Lenstar LS 900, and OA-2000 were recorded. The IOL powers were calculated with the Hoffer Q, Holladay 1, SRK/T, and Haigis formulas. The repeatability was evaluated using the within-subject standard deviation (Sw), repeatability coefficient (RC), coefficient of variation (COV), and intraclass correlation coefficient (ICC). Inter-device agreement between the four biometers was assessed with the 95% limits of agreement. RESULTS: In total, 101 right eyes of 101 participants were enrolled. The Anterion showed good repeatability for all the included biometric parameters with all the CoV ≤ 0.30% and ICC ≥ 0.930 except for J45 with moderate repeatability (ICC was 0.849). Good agreement was found among the four devices for Kf, Ks, J0, J45, ACD, and AL. Generally, wide 95% LoA was found for the predicted IOL powers with the four IOL calculation formulas between the four devices. CONCLUSIONS: The Anterion showed good repeatability of biometric measurements for most parameters. Good agreement among the four optical biometers was achieved for all the parameters except for CCT and the predicted IOL power. The AL values exhibited the best repeatability with Anterion and the best agreement among the biometers in our study.


Subject(s)
Axial Length, Eye , Lenses, Intraocular , Anterior Chamber/anatomy & histology , Anterior Chamber/diagnostic imaging , Axial Length, Eye/anatomy & histology , Biometry , Cornea/diagnostic imaging , Humans , Prospective Studies , Reproducibility of Results , Tomography, Optical Coherence
SELECTION OF CITATIONS
SEARCH DETAIL
...