Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sleep Med ; 117: 152-161, 2024 May.
Article in English | MEDLINE | ID: mdl-38547592

ABSTRACT

OBJECTIVE: To explore sleep structure in participants with obstructive sleep apnea (OSA) and comorbid insomnia (COMISA) and participants with OSA without insomnia (OSA-only) using both single-night polysomnography and multi-night wrist-worn photoplethysmography/accelerometry. METHODS: Multi-night 4-class sleep-staging was performed with a validated algorithm based on actigraphy and heart rate variability, in 67 COMISA (23 women, median age: 51 years) and 50 OSA-only (15 women, median age: 51) participants. Sleep statistics were compared using linear regression models and mixed-effects models. Multi-night variability was explored using a clustering approach and between- and within-participant analysis. RESULTS: Polysomnographic parameters showed no significant group differences. Multi-night measurements, during 13.4 ± 5.2 nights per subject, demonstrated a longer sleep onset latency and lower sleep efficiency for the COMISA group. Detailed analysis of wake parameters revealed longer mean durations of awakenings in COMISA, as well as higher numbers of awakenings lasting 5 min and longer (WKN≥5min) and longer wake after sleep onset containing only awakenings of 5 min or longer. Within-participant variance was significantly larger in COMISA for sleep onset latency, sleep efficiency, mean duration of awakenings and WKN≥5min. Unsupervised clustering uncovered three clusters; participants with consistently high values for at least one of the wake parameters, participants with consistently low values, and participants displaying higher variability. CONCLUSION: Patients with COMISA more often showed extended, and more variable periods of wakefulness. These observations were not discernible using single night polysomnography, highlighting the relevance of multi-night measurements to assess characteristics indicative for insomnia.


Subject(s)
Sleep Apnea, Obstructive , Sleep Initiation and Maintenance Disorders , Humans , Female , Middle Aged , Sleep/physiology , Polysomnography , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/diagnosis , Actigraphy
2.
Sleep Breath ; 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-38062226

ABSTRACT

PURPOSE: Comorbid insomnia often occurs in patients with obstructive sleep apnea (OSA), referred to as COMISA. Cortical arousals manifest as a common feature in both OSA and insomnia, often accompanied by elevated heart rate (HR). Our objective was to evaluate the heart rate response to nocturnal cortical arousals in patients with COMISA and patients with OSA alone. METHODS: We analyzed data from patients with COMISA and from patients with OSA matched for apnea-hypopnea index. Sleep staging and analysis of respiratory events and cortical arousals were performed using the Philips Somnolyzer automatic scoring system. Beat-by-beat HR was analyzed from the onset of the cortical arousal to 30 heartbeats afterwards. HR responses were divided into peak and recovery phases. Cortical arousals were separately evaluated according to subtype (related to respiratory events and spontaneous) and duration (3-6 s, 6-10 s, 10-15 s). RESULTS: A total of 72 patients with COMISA and 72 patients with OSA were included in this study. There were no overall group differences in the number of cortical arousals with and without autonomic activation. No significant differences were found for spontaneous cortical arousals. The OSA group had more cortical arousals related to respiratory events (21.0 [14.8-30.0] vs 16.0 [9.0-27.0], p = 0.016). However, the COMISA group had longer cortical arousals (7.2 [6.4-7.8] vs 6.7 [6.2-7.7] s, p = 0.024) and the HR recovery phase was prolonged (52.5 [30.8-82.5] vs 40.0 [21.8-55.5] beats/min, p = 0.017). Both the peak and the recovery phase for longer cortical arousals with a duration of 10-15 s were significantly higher in patients with COMISA compared to patients with OSA (47.0 [27.0-97.5] vs 34.0 [21.0-71.0] beats/min, p = 0.032 and 87.0 [47.0-132.0] vs 71.0 [43.0-103.5] beats/min, p = 0.049, respectively). CONCLUSIONS: The HR recovery phase after cortical arousals related to respiratory events is prolonged in patients with COMISA compared to patients with OSA alone. This response could be indicative of the insomnia component in COMISA.

3.
J Clin Sleep Med ; 19(6): 1051-1059, 2023 06 01.
Article in English | MEDLINE | ID: mdl-36740913

ABSTRACT

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) and insomnia frequently co-occur, making diagnosis and treatment challenging. We investigated differences in sleep structure between patients with OSA, insomnia, and comorbid insomnia and sleep apnea (COMISA) to identify characteristics that can be used to improve the diagnosis of COMISA. METHODS: We obtained polysomnography data of 326 patients from the Sleep and OSA Monitoring with Non-Invasive Applications database. The group included patients with OSA (n = 199), insomnia (n = 47), and COMISA (n = 80). We compared statistics related to sleep structure between the 3 patient groups. RESULTS: Wake after sleep onset was significantly shorter for the OSA group (median: 60.0 minutes) compared to the COMISA (median: 83.3 minutes, P < .01) and the insomnia (median: 83.5 minutes, P = .01) groups. No significant differences were found in the total number of awakenings and the number of short (up to and including 2 minutes) and medium-length awakenings (2.5 up to and including 4.5 minutes). However, the number of long awakenings (5 minutes or longer) and wake after sleep onset containing only long awakenings was significantly lower for patients with OSA (median: 2 awakenings and 25.5 minutes) compared to patients with COMISA (median: 3 awakenings, P < .01 and 43.3 minutes, P < .001) or with insomnia (median: 3 awakenings, P < .01 and 56.0 minutes, P < .001). Total sleep time was significantly longer and sleep efficiency was significantly higher for the OSA group (median: 418.5 minutes and 84.4%) compared to both the COMISA (median: 391.5 minutes, P < .001 and 77.3%, P < .001) and the insomnia (median: 381.5 minutes, P < .001 and 78.2%, P < .001) groups. The number of sleep-stage transitions during the night for patients with COMISA (median: 194.0) was lower compared to that for patients with OSA (median: 218.0, P < .01) and higher compared to that for patients with insomnia (median: 156.0, P < .001). Other sleep architectural parameters were not discriminative between the groups. CONCLUSIONS: Patients with COMISA show specific characteristics of insomnia, including prolonged awakenings. This variable is distinctive in comparison to patients with OSA. The combination of prolonged awakenings and the presence of sleep-disordered breathing leads to increased sleep disturbance compared to patients having only 1 of the sleep disorders. CITATION: Wulterkens BM, Hermans LWA, Fonseca P, et al. Sleep structure in patients with COMISA compared to OSA and insomnia. J Clin Sleep Med. 2023;19(6):1051-1059.


Subject(s)
Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Sleep Initiation and Maintenance Disorders , Sleep Wake Disorders , Humans , Sleep Initiation and Maintenance Disorders/complications , Sleep Initiation and Maintenance Disorders/epidemiology , Sleep , Sleep Apnea Syndromes/diagnosis , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/epidemiology , Comorbidity , Sleep Wake Disorders/complications
4.
Nat Sci Sleep ; 13: 885-897, 2021.
Article in English | MEDLINE | ID: mdl-34234595

ABSTRACT

PURPOSE: There is great interest in unobtrusive long-term sleep measurements using wearable devices based on reflective photoplethysmography (PPG). Unfortunately, consumer devices are not validated in patient populations and therefore not suitable for clinical use. Several sleep staging algorithms have been developed and validated based on ECG-signals. However, translation from these techniques to data derived by wearable PPG is not trivial, and requires the differences between sensing modalities to be integrated in the algorithm, or having the model trained directly with data obtained with the target sensor. Either way, validation of PPG-based sleep staging algorithms requires a large dataset containing both gold standard measurements and PPG-sensor in the applicable clinical population. Here, we take these important steps towards unobtrusive, long-term sleep monitoring. METHODS: We developed and trained an algorithm based on wrist-worn PPG and accelerometry. The method was validated against reference polysomnography in an independent clinical population comprising 244 adults and 48 children (age: 3 to 82 years) with a wide variety of sleep disorders. RESULTS: The classifier achieved substantial agreement on four-class sleep staging with an average Cohen's kappa of 0.62 and accuracy of 76.4%. For children/adolescents, it achieved even higher agreement with an average kappa of 0.66 and accuracy of 77.9%. Performance was significantly higher in non-REM parasomnias (kappa = 0.69, accuracy = 80.1%) and significantly lower in REM parasomnias (kappa = 0.55, accuracy = 72.3%). A weak correlation was found between age and kappa (ρ = -0.30, p<0.001) and age and accuracy (ρ = -0.22, p<0.001). CONCLUSION: This study shows the feasibility of automatic wearable sleep staging in patients with a broad variety of sleep disorders and a wide age range. Results demonstrate the potential for ambulatory long-term monitoring of clinical populations, which may improve diagnosis, estimation of severity and follow up in both sleep medicine and research.

SELECTION OF CITATIONS
SEARCH DETAIL
...