Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Bioengineering (Basel) ; 10(11)2023 Nov 10.
Article in English | MEDLINE | ID: mdl-38002431

ABSTRACT

BACKGROUND: Although electronic health records (EHR) provide useful insights into disease patterns and patient treatment optimisation, their reliance on unstructured data presents a difficulty. Echocardiography reports, which provide extensive pathology information for cardiovascular patients, are particularly challenging to extract and analyse, because of their narrative structure. Although natural language processing (NLP) has been utilised successfully in a variety of medical fields, it is not commonly used in echocardiography analysis. OBJECTIVES: To develop an NLP-based approach for extracting and categorising data from echocardiography reports by accurately converting continuous (e.g., LVOT VTI, AV VTI and TR Vmax) and discrete (e.g., regurgitation severity) outcomes in a semi-structured narrative format into a structured and categorised format, allowing for future research or clinical use. METHODS: 135,062 Trans-Thoracic Echocardiogram (TTE) reports were derived from 146967 baseline echocardiogram reports and split into three cohorts: Training and Validation (n = 1075), Test Dataset (n = 98) and Application Dataset (n = 133,889). The NLP system was developed and was iteratively refined using medical expert knowledge. The system was used to curate a moderate-fidelity database from extractions of 133,889 reports. A hold-out validation set of 98 reports was blindly annotated and extracted by two clinicians for comparison with the NLP extraction. Agreement, discrimination, accuracy and calibration of outcome measure extractions were evaluated. RESULTS: Continuous outcomes including LVOT VTI, AV VTI and TR Vmax exhibited perfect inter-rater reliability using intra-class correlation scores (ICC = 1.00, p < 0.05) alongside high R2 values, demonstrating an ideal alignment between the NLP system and clinicians. A good level (ICC = 0.75-0.9, p < 0.05) of inter-rater reliability was observed for outcomes such as LVOT Diam, Lateral MAPSE, Peak E Velocity, Lateral E' Velocity, PV Vmax, Sinuses of Valsalva and Ascending Aorta diameters. Furthermore, the accuracy rate for discrete outcome measures was 91.38% in the confusion matrix analysis, indicating effective performance. CONCLUSIONS: The NLP-based technique yielded good results when it came to extracting and categorising data from echocardiography reports. The system demonstrated a high degree of agreement and concordance with clinician extractions. This study contributes to the effective use of semi-structured data by providing a useful tool for converting semi-structured text to a structured echo report that can be used for data management. Additional validation and implementation in healthcare settings can improve data availability and support research and clinical decision-making.

2.
BMC Med ; 19(1): 23, 2021 01 21.
Article in English | MEDLINE | ID: mdl-33472631

ABSTRACT

BACKGROUND: The National Early Warning Score (NEWS2) is currently recommended in the UK for the risk stratification of COVID-19 patients, but little is known about its ability to detect severe cases. We aimed to evaluate NEWS2 for the prediction of severe COVID-19 outcome and identify and validate a set of blood and physiological parameters routinely collected at hospital admission to improve upon the use of NEWS2 alone for medium-term risk stratification. METHODS: Training cohorts comprised 1276 patients admitted to King's College Hospital National Health Service (NHS) Foundation Trust with COVID-19 disease from 1 March to 30 April 2020. External validation cohorts included 6237 patients from five UK NHS Trusts (Guy's and St Thomas' Hospitals, University Hospitals Southampton, University Hospitals Bristol and Weston NHS Foundation Trust, University College London Hospitals, University Hospitals Birmingham), one hospital in Norway (Oslo University Hospital), and two hospitals in Wuhan, China (Wuhan Sixth Hospital and Taikang Tongji Hospital). The outcome was severe COVID-19 disease (transfer to intensive care unit (ICU) or death) at 14 days after hospital admission. Age, physiological measures, blood biomarkers, sex, ethnicity, and comorbidities (hypertension, diabetes, cardiovascular, respiratory and kidney diseases) measured at hospital admission were considered in the models. RESULTS: A baseline model of 'NEWS2 + age' had poor-to-moderate discrimination for severe COVID-19 infection at 14 days (area under receiver operating characteristic curve (AUC) in training cohort = 0.700, 95% confidence interval (CI) 0.680, 0.722; Brier score = 0.192, 95% CI 0.186, 0.197). A supplemented model adding eight routinely collected blood and physiological parameters (supplemental oxygen flow rate, urea, age, oxygen saturation, C-reactive protein, estimated glomerular filtration rate, neutrophil count, neutrophil/lymphocyte ratio) improved discrimination (AUC = 0.735; 95% CI 0.715, 0.757), and these improvements were replicated across seven UK and non-UK sites. However, there was evidence of miscalibration with the model tending to underestimate risks in most sites. CONCLUSIONS: NEWS2 score had poor-to-moderate discrimination for medium-term COVID-19 outcome which raises questions about its use as a screening tool at hospital admission. Risk stratification was improved by including readily available blood and physiological parameters measured at hospital admission, but there was evidence of miscalibration in external sites. This highlights the need for a better understanding of the use of early warning scores for COVID.


Subject(s)
COVID-19/diagnosis , Early Warning Score , Aged , COVID-19/epidemiology , COVID-19/virology , Cohort Studies , Electronic Health Records , Female , Humans , Male , Middle Aged , Pandemics , Prognosis , SARS-CoV-2/isolation & purification , State Medicine , United Kingdom/epidemiology
4.
Cardiovasc Intervent Radiol ; 27(6): 632-6, 2004.
Article in English | MEDLINE | ID: mdl-15578140

ABSTRACT

Aortic stent grafting may be an alternative to surgery for patients with an abdominal aortic aneurysm and coexistent horseshoe kidney but is not without difficulties. This study examines the renal consequences of aortic stent grafting in such patients. This is a retrospective review of patients with horseshoe kidney in whom aortic stent grafting was performed between December 1995 and August 2000. Follow-up occurred within the EUROSTAR protocol and included measurement of serum creatinine. Of 130 patients in whom aortic stent grafting was performed, 4 had coexistent horseshoe kidney. In all patients the aneurysm was successfully excluded with the occlusion of between one and four anomalous renal arteries. At follow-up, no clinically significant renal impairment was detected. Endovascular aneurysm repair is an attractive option for patients with a horseshoe kidney and normal preoperative creatinine levels.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Kidney/abnormalities , Stents , Aged , Aortic Aneurysm, Abdominal/complications , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Creatinine/blood , Follow-Up Studies , Humans , Kidney/blood supply , Kidney/diagnostic imaging , Kidney Diseases/complications , Kidney Diseases/diagnostic imaging , Male , Middle Aged , Renal Artery/diagnostic imaging , Renal Artery/surgery , Retrospective Studies , Stents/adverse effects , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...