Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 11(1): 24490, 2021 12 29.
Article in English | MEDLINE | ID: mdl-34966168

ABSTRACT

During the first wave of Covid-19 infections in Germany in April 2020, clinics reported a shortage of filtering face masks with aerosol retention> 94% (FFP2 & 3, KN95, N95). Companies all over the world increased their production capacities, but quality control of once-certified materials and masks came up short. To help identify falsely labeled masks and ensure safe protection equipment, we tested 101 different batches of masks in 993 measurements with a self-made setup based on DIN standards. An aerosol generator provided a NaCl test aerosol which was applied to the mask. A laser aerosol spectrometer measured the aerosol concentration in a range from 90 to 500 nm to quantify the masks' retention. Of 101 tested mask batches, only 31 batches kept what their label promised. Especially in the initial phase of the pandemic in Germany, we observed fluctuating mask qualities. Many batches show very high variability in aerosol retention. In addition, by measuring with a laser aerosol spectrometer, we were able to show that not all masks filter small and large particles equally well. In this study we demonstrate how important internal and independent quality controls are, especially in times of need and shortage of personal protection equipment.


Subject(s)
COVID-19/prevention & control , COVID-19/transmission , Masks/statistics & numerical data , Aerosols , Filtration/instrumentation , Germany , Humans , Masks/standards , Masks/trends , N95 Respirators/standards , N95 Respirators/statistics & numerical data , Occupational Exposure/prevention & control , Pandemics/prevention & control , Personal Protective Equipment/standards , Quality Control , Respiratory Protective Devices/standards , SARS-CoV-2/pathogenicity
2.
IEEE Trans Biomed Eng ; 66(3): 821-830, 2019 03.
Article in English | MEDLINE | ID: mdl-30028689

ABSTRACT

OBJECTIVE: For tissue engineering, there is a need for quantitative methods to map cell density inside three-dimensional (3-D) bioreactors to assess tissue growth over time. The current cell mapping methods in 2-D cultures are based on optical microscopy. However, optical methods fail in 3-D due to increased opacity of the tissue. We present an approach for measuring the density of cells embedded in a hydrogel to generate quantitative maps of cell density in a living, 3-D tissue culture sample. METHODS: Quantification of cell density was obtained by calibrating the 1H T2, magnetization transfer (MT) and diffusion-weighted nuclear magnetic resonance (NMR) signals to samples of known cell density. Maps of cell density were generated by weighting NMR images by these parameters post-calibration. RESULTS: The highest sensitivity weighting arose from MT experiments, which yielded a limit of detection (LOD) of [Formula: see text] cells/mL/ √{Hz} in a 400 MHz (9.4 T) magnet. CONCLUSION: This mapping technique provides a noninvasive means of visualizing cell growth within optically opaque bioreactors. SIGNIFICANCE: We anticipate that such readouts of tissue culture growth will provide valuable feedback for controlled cell growth in bioreactors.


Subject(s)
Cell Count/methods , Hydrogels/chemistry , Imaging, Three-Dimensional/methods , Magnetic Resonance Spectroscopy/methods , Bioreactors , Cells, Cultured , HEK293 Cells , Humans , Saccharomyces cerevisiae/cytology , Signal Processing, Computer-Assisted , Tissue Engineering
SELECTION OF CITATIONS
SEARCH DETAIL
...