Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 45(3): 355-360, 2023 Jun.
Article in Chinese | MEDLINE | ID: mdl-37407521

ABSTRACT

Objective To establish a nomogram for predicting the risk of cervical lymph node metastasis in differentiated thyroid carcinoma (DTC). Methods The patients with complete clinical data of DTC and cervical lymph node ultrasound and diagnosed based on pathological evidence from January 2019 to December 2021 were assigned into a training group (n=444) and a validation group (n=125).Lasso regression was performed to screen the data with differences between groups,and multivariate Logistic regression to establish a prediction model with the factors screened out by Lasso regression.C-index and calibration chart were employed to evaluate the prediction performance of the established model. Results The predictive factors for establishing the model were lymph node short diameter≥0.5 cm,long-to-short-axis ratio<2,disappearance of lymph node hilum,cystic transformation,hyperechogenicity,calcification,and abnormal blood flow (all P<0.001).The established model demonstrated a good discriminative ability,with the C index of 0.938 (95%CI=0.926-0.961) in the training group. Conclusion The nomogram established based on the ultrasound image features of cervical lymph nodes in DTC can accurately predict the risk of cervical lymph node metastasis in DTC.


Subject(s)
Adenocarcinoma , Thyroid Neoplasms , Humans , Nomograms , Lymphatic Metastasis , Lymph Nodes/pathology , Neck/pathology , Thyroid Neoplasms/pathology , Adenocarcinoma/pathology , Retrospective Studies
2.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 45(3): 361-365, 2023 Jun.
Article in Chinese | MEDLINE | ID: mdl-37407522

ABSTRACT

Objective To evaluate extrathyroidal extension (ETE) in papillary thyroid microcarcinoma (PTMC) with three-dimensional tomographic ultrasound imaging (3D-TUI). Methods A total of 97 thyroid nodules of 79 patients with PTMC treated in PUMC Hospital from February 2016 to January 2018 were included in this study.Two ultrasound experts performed independent blinded assessment of the relationship between thyroid nodules and thyroid capsule by two-dimensional ultrasound (2D-US) and 3D-TUI.The results of 2D-US and 3D-TUI in evaluating ETE were compared with intraoperative findings and postoperative histological and pathological results. Results Among the 97 nodules,54 (55.7%) nodules had ETE.The diagnostic sensitivity (68.5% vs.37.0%;χ2=10.737,P=0.002),accuracy (74.5% vs.56.7%;χ2=6.686,P=0.015),and area under the receiver operating characteristic curve[0.761 (95%CI=0.677-0.845) vs.0.592 (95%CI=0.504-0.680);Z=3.500,P<0.001] of 3D-TUI were higher than those of 2D-US.However,3D-TUI and 2D-US showed no significant difference in the specificity (84.1% vs.81.4%;χ2=0.081,P=0.776),negative predictive value (67.9% vs.50.7%;χ2=3.645,P=0.066),or positive predictive value (84.1% vs.71.4%;χ2=1.663,P=0.240). Conclusion Compared with 2D-US,3D-TUI demonstrates increased diagnostic efficiency for ETE of PTMC.


Subject(s)
Carcinoma, Papillary , Thyroid Neoplasms , Thyroid Nodule , Humans , Thyroid Neoplasms/diagnosis , Carcinoma, Papillary/pathology , Ultrasonography/methods , Retrospective Studies
3.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 45(3): 366-373, 2023 Jun.
Article in Chinese | MEDLINE | ID: mdl-37407523

ABSTRACT

Objective To investigate the influencing factors and establish a model predicting the performance of needle visualization in fine-needle aspiration (FNA) of thyroid nodules. Methods This study prospectively included 175 patients who underwent FNA of thyroid nodules in the Department of Ultrasound in China-Japan Friendship Hospital and compared the display of the needle tips in the examination of 199 thyroid nodules before and after the application of needle visualization.We recorded the location,the positional relationship with thyroid capsule,ultrasonic characteristics,and the distribution of the soft tissue strip structure at the puncture site of the nodules with unclear needle tips display before using needle visualization.Furthermore,according to the thyroid imaging reporting and data system proposed by the American College of Radiology,we graded the risk of the nodules.Lasso-Logistic regression was employed to screen out the factors influencing the performance of needle visualization and establish a nomogram for prediction. Results The needle tips were not clearly displayed in the examination of 135 (67.8%) and 53 (26.6%) nodules before and after the application of needle visualization,respectively,which showed a significant difference (P<0.001).Based on the positional relationship between the nodule and capsule,anteroposterior/transverse diameter (A/T) ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site,a nomogram was established to predict the probability of unclear display of the needle tips after application of needle visualization.The C-index of the prediction model was 0.75 (95%CI=0.67-0.84) and the area under the receiver operating characteristic curve was 0.72.The calibration curve confirmed the appreciable reliability of the prediction model,with the C-index of 0.70 in internal validation. Conclusions Needle visualization can improve the display of the needle tip in ultrasound-guided FNA of thyroid nodules.The nomogram established based on ultrasound features such as the positional relationship between the nodule and capsule,A/T ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site can predict whether needle visualization is suitable for the examination of nodules.


Subject(s)
Thyroid Neoplasms , Thyroid Nodule , Humans , Thyroid Nodule/diagnostic imaging , Biopsy, Fine-Needle/methods , Reproducibility of Results , Ultrasonography , Retrospective Studies
4.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 45(6): 929-933, 2023 Dec 30.
Article in Chinese | MEDLINE | ID: mdl-38173103

ABSTRACT

Objective To investigate the influencing factors of Bethesda Ⅲ results in fine-needle aspiration biopsy of thyroid nodules.Methods A total of 300 thyroid nodules with cytological diagnosis results were analyzed retrospectively,including 100 Bethesda Ⅲ nodules and 50 nodules of Bethesda Ⅱ,Ⅳ,Ⅴ,and Ⅵ categories,respectively.Univariate analysis and Logistic regression analysis were performed on the clinical data of patients and the ultrasound signs of thyroid nodules to clarify the factors influencing the diagnosis of Bethesda Ⅲ nodules.Results Univariate analysis showed that Bethesda Ⅲ nodules were mostly adjacent to the capsule(P<0.001),with no blood flow in the color Doppler assessment(P=0.011)and lack of blood supply(P=0.033)and maximum diameter ≤0.9 cm(P=0.038)as revealed by the contrast-enhanced ultrasound.Logistic regression showed that the position close to the capsule(OR=5.110,95%CI=2.153-12.130,P<0.001)and color Doppler without blood flow signal(OR=3.015,95%CI=1.094-8.311,P=0.033)were independent risk factors for the diagnosis of Bethesda Ⅲ nodules.Conclusions The puncture difficulty caused by the dangerous position of thyroid nodules close to the capsule and the aspiration difficulty caused by the absence of blood flow signal in color Doppler are the main factors influencing the diagnosis of Bethesda Ⅲ nodules.Therefore,corresponding avoidance measures should be taken during the aspiration process to reduce the diagnosis results of Bethesda Ⅲ nodules.


Subject(s)
Thyroid Neoplasms , Thyroid Nodule , Humans , Thyroid Nodule/diagnostic imaging , Thyroid Neoplasms/diagnosis , Biopsy, Fine-Needle/methods , Retrospective Studies , Ultrasonography/methods
5.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 39(5): 675-681, 2017 10 30.
Article in English | MEDLINE | ID: mdl-29125111

ABSTRACT

Objective To explore the ultrasound features and levels of cervical lymph node metastases in primary and recurrent/persistent papillary thyroid cancer (PTC).Methods We retrospectively analyzed the clinical data of 2181 patients who underwent cervical lymph nodes dissection for PTC from January 1st 2015 to January 1st 2016.Totally 418 PTC patients (with 622 lymph nodes) who met the inclusion criteria entered the final analysis.Patients who had not received any prior thyroid treatment (surgery with or without radioactive iodine) were categorized as the primary group (352 patients with 527 metastatic lymph nodes),and patients who had received prior treatment (thyroidectomy with or without radioactive iodine) for PTC were categorized as recurrent/persistent group (66 patients with 95 metastatic lymph nodes).Pathological results from lymph node dissections were used as the gold standards by means of level-to-level analysis.Results The mean of the minimum axis diameter of the lymph nodes in the primary group was (6.7±3.6)mm,and that of the recurrent/persistent group was (6.6±3.1)mm (U=0.180,P=0.857).The proportion of metastasis in the central area of primary group was 40.0%,which was significantly higher than that in the recurrent/persistent group (12.6%);the proportion of metastasis in the lateral area was 60.6% in the primary group,which was significantly lower than that in the recurrent/persistent group (87.4%)(χ2=26.288,P<0.001).In lateral metastatic lymph nodes,Ⅲ level was the most common place in both groups.Level Ⅴ metastatic lymph was rare in both primary group and recurrent/persistent group.Calcifications (63.1% vs. 48.2%;χ2=7.207,P=0.007) and peripheral vascularity (81.1% vs. 59.4%;χ2= 16.147, P<0.001) were more common in the recurrent/persistent group.The round shape,absence of an echogenic hilum,hyperechogenicity,and cystic aspects were not significantly different between these two groups (all P>0.05).Conclusions Primary metastatic lymph nodes often occur in the central area of lymph nodes,while lateral metastatic lymph nodes are more common in recurrent/persistent PTC.For metastatic lymph nodes,calcifications and peripheral vascularity are more common in recurrent/persistent PTC.


Subject(s)
Carcinoma, Papillary/diagnostic imaging , Lymph Nodes/diagnostic imaging , Thyroid Cancer, Papillary/diagnostic imaging , Thyroid Neoplasms/diagnostic imaging , Humans , Lymphatic Metastasis/diagnostic imaging , Neoplasm Recurrence, Local/diagnostic imaging , Retrospective Studies , Thyroidectomy
6.
Medicine (Baltimore) ; 96(16): e6564, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28422844

ABSTRACT

BACKGROUND: Fine-needle aspiration (FNA) is the most dependable tool to triage thyroid nodules for medical or surgical management. However, Bethesda class III cytology, namely "follicular lesion of undetermined significance" (FLUS) or "atypia of undetermined significance" (AUS), is a major limitation of the US-FNA in assessing thyroid nodules. As the most important imaging method, ultrasound (US) has a high efficacy in diagnosing thyroid nodules. This meta-analysis aimed to assess the role of US in evaluating Bethesda class III thyroid nodules. METHODS: With keywords "Undetermined Significance," "Bethesda Category III," "Bethesda system," "Cytological Subcategory," "AUS/FLUS," "Atypia of Undetermined Significance," and "Ultrasound/US," papers in PubMed, Cochrane Library, Medline, Web of Science, Embase, and Google Scholar from inception to December 2016 were searched. A meta-analysis of these trials was then performed for evaluating the diagnostic value of thyroid ultrasound in Bethesda Category III thyroid nodules. RESULTS: Fourteen studies including 2405 nodules were analyzed. According to the criteria for US diagnosis of thyroid nodules in each article, with any one of suspicious features as indictors of malignancy, US had a pooled sensitivity of 0.75 (95% CI 0.72-0.78) and a pooled specificity of 0.48 (95% CI 0.45-0.50) in evaluating Bethesda Class III Nodules. The pooled diagnostic odds ratio was 10.92 (95% CI 6.04-19.74). The overall area under the curve was 0.84 and the Q* index was 0.77. With any 2 or 3 of US suspicious features as indictors of malignancy, the sensitivity and specificity were 0.77 (95% CI 0.71-0.83) and 0.54 (95% CI 0.51-0.58), 0.66 (95% CI 0.59-0.73) and 0.71 (95% CI 0.68-0.74), respectively. CONCLUSIONS: US was helpful for differentiating benign and malignant Bethesda class III thyroid nodules, with the more suspicious features, the more likely to be malignant.


Subject(s)
Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Ultrasonography/methods , Biopsy, Fine-Needle , Diagnosis, Differential , Humans , Odds Ratio , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...