Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Infect Dis Model ; 9(1): 56-69, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38130878

ABSTRACT

In this paper, with the method of epidemic dynamics, we assess the spread and prevalence of COVID-19 after the policy adjustment of prevention and control measure in December 2022 in Taiyuan City in China, and estimate the excess population deaths caused by COVID-19. Based on the transmission mechanism of COVID-19 among individuals, a dynamic model with heterogeneous contacts is established to describe the change of control measures and the population's social behavior in Taiyuan city. The model is verified and simulated by basing on reported case data from November 8th to December 5th, 2022 in Taiyuan city and the statistical data of the questionnaire survey from December 1st to 23rd, 2022 in Neijiang city. Combining with reported numbers of permanent residents and deaths from 2017 to 2021 in Taiyuan city, we apply the dynamic model to estimate theoretical population of 2022 under the assumption that there is no effect of COVID-19. In addition, we carry out sensitivity analysis to determine the propagation character of the Omicron strain and the effect of the control measures. As a result of the study, it is concluded that after adjusting the epidemic policy on December 6th, 2022, three peaks of infection in Taiyuan are estimated to be from December 22nd to 31st, 2022, from May 10th to June 1st, 2023, and from September 5th to October 13th, 2023, and the corresponding daily peaks of new cases can reach 400 000, 44 000 and 22 000, respectively. By the end of 2022, excess deaths can range from 887 to 4887, and excess mortality rate can range from 3.06% to 14.82%. The threshold of the infectivity of the COVID-19 variant is estimated 0.0353, that is if the strain infectivity is above it, the epidemic cannot be control with the previous normalization measures.

2.
Rev Sci Instrum ; 86(1): 016106, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25638133

ABSTRACT

This note presents an improved high-resolution frequency measurement system dedicated for the inter-satellite range-rate monitoring that could be used in the future's gravity recovery mission. We set up a simplified common signal test instead of the three frequencies test. The experimental results show that the dominant noises are the sampling time jitter and the thermal drift of electronic components, which can be reduced by using the pilot-tone correction and passive thermal control. The improved noise level is about 10(-8) Hz/Hz(1/2)@0.01Hz, limited by the signal-to-noise ratio of the sampling circuit.

SELECTION OF CITATIONS
SEARCH DETAIL
...