Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters











Language
Publication year range
1.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1024989

ABSTRACT

【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1024990

ABSTRACT

【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.

3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1024991

ABSTRACT

【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

4.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1024992

ABSTRACT

【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

5.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-883320

ABSTRACT

Objective:To investigate the clinical and genetic mutation characteristics of a pedigree with familial exudative vitreoretinopathy (FEVR) associated with a LRP5 gene mutation. Methods:A pedigree investigation was performed in a two-generation Chinese Han family with FEVR, which was diagnosed in The First Affiliated Hospital of Xi'an Jiaotong University.Three family members, the proband and his parents, underwent ophthalmic examination, including visual acuity, intraocular pressure, slit-lamp microscopy, fundoscopy and wild-field fundus fluorescein angiography (FFA), to clinically characterize the FEVR phenotype.Peripheral blood of the families were collected for high-throughput sequencing and bioinformatics analysis to identify the pathogenic gene.Sanger sequencing verification was conducted for the detected mutation.The pathogenicity of identified mutations was analyzed according to the guidelines of the American Association of Medical Genetics (ACMG) with software such as Mutation Taster, Polyphen-2, PROVEN and REVEL.This study adhered to the Declaration of Helsinki and was approved by an Ethics Committee of The First Affiliated Hospital of Xi'an Jiaotong University (No.2017-740). Written informed consent was obtained from each subject.Results:The proband was a 27-year-old male.Uncorrected visual acuity (UCVA) was 1.0 for his right eye and 1.2 for his left eye.Fundoscopy showed vascular tortuosity and vasodilation in the temporal peripheral retina of both eyes.FFA indicated that hairbrush-like vasculature and non-perfusion lesion in peripheral retina.The best-corrected visual acuity (BCVA) of the proband's mother, a 51-year old female, was 1.0 for the both eyes.Temporal retinal vascular tortuosity in her left eye was found with fluorescein leakage detected by FFA.The BCVA of the proband's father, a 56-year-old male, was 1.0 for both eyes.Leopard fundus and optic disc atrophy were visible.FFA result was normal.The result of genetic test showed that there were two novel gene mutations in the family with LRP5 gene c. 4110T>G(p.Cys1370Trp) and FSCN2 gene c. 1495G>A(p.Gly499Ser). According to guidelines of ACMG, LPR5 c. 4110T>G was a mutation with uncertain significance.Multiple software, such as MutationTaster, Polyphen-2, PROVEN and REVEL predicted that LRP5 c. 4110T>G mutation might cause detrimental effects on genes or gene products.REVEL scale was 0.93, which indicated that it might be a pathogenic variant. Conclusions:LRP5 gene c. 4110T>G(p.Cys1370Trp) may be a novel mutation for FEVR, which enriches the mutation spectrum of LRP5 gene.

6.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-699805

ABSTRACT

Objective To observe the long-term clinical efficacy of intravitreal ranibizumab (IVR) in patients with idiopathic choroidal neovascularization (ICNV),and to explore the indicators that affect curative effect.Methods A retrospective self-controlled study was performed.The clinical data of 61 ICNV patients (61 eyes) from January 2013 to May 2014 in the First Affiliated Hospital of Xi'an Jiaotong University were Collected.The best corrected visual acuity (BCVA),the central retinal thickness (CRT),the height of pigment epithelium detachment (PED) and the defect length of ellipsoidal zone (EZ) before and after treatment were analyzed,the baseline clinical indicators were compared among different IVR treatment times and ICNV types.Results The mean follow-up time was (41.5±4.6) months.The mean BCVA (LogMAR) were 0.59±0.32 and 0.17 ± 0.12,the mean CRT were (331.18±80.42) μm and (245.07±44.67) μm,the mean height of PED were (246.73±104.75) μm and (205.78±117.01) μm and the mean defect length of EZ were (2 315.10± 1 233.77) μm and (1 325.98± 1 157.30) μm before and after treatment,respectively,with significant differences between before and after treatment (all at P<0.05).Fifty-three patients (86.89%) completed the treatment in the first year or within three times.The mean CRT and the height of PED in the IVR ≥ 3 times treatment group were significantly higher than those in the IVR 1 times treatment group (all at P<0.05).There was no significant difference in the average treatment times among inferior lateral of macular fovea,side of macular fovea and outside of macular fovea (F =1.982,P > 0.05).Conclusions IVR therapy for ICNV is well tolerated with an improvement in BCVA,CRT,height of PED and defect length of EZ.The majority of patients can complete the treatment within 1 year,and most patients can be cured within 3 times treatments.The number of treatments may be associated with the CRT and the height of PED at baseline.

7.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-749725

ABSTRACT

OBJECTIVE@#Through 3.0 T MRI study the ear and sinus lesions of patients with acute carbon monoxide poisoning.@*METHOD@#From 2012 to 2015 collected the MRI images of the 45 patients with acute carbon monoxide poisoning, observe their changes of middle ear and mastoid and sinus imaging.@*RESULT@#The middle ear injury of mastoid 41 cases (91.1%), 22 cases (48.9%) of maxillary sinus injury, ethmoid sinus injury in 20 cases (44.4%), sphenoid sinus 9 cases (20.0%), 5 cases (11.1%) of frontal sinus injury. Carbon monoxide poisoning patients according to clinical symptoms can be divided into light, medium and heavy 3 groups, observing the ear sinus damage degree for comparison between groups, found to have significant differences (P < 0.05).@*CONCLUSION@#The patients with acute carbon monoxide poisoning ear and sinus injury should cause the attention of the medical staff, MRI can reflect people's ears from the details and the damage degree of the sinuses.


Subject(s)
Humans , Carbon Monoxide Poisoning , Diagnosis , Ear, Middle , Pathology , Ethmoid Sinus , Pathology , Frontal Sinus , Pathology , Magnetic Resonance Imaging , Maxillary Sinus , Pathology , Paranasal Sinuses , Pathology , Sphenoid Sinus , Pathology
8.
Chinese Journal of Zoonoses ; (12): 163-167, 2010.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-433113

ABSTRACT

The complete length of P gene from rabies virus was amplified by RT-PCR using a pair of specific primers designed according to the relevant sequences from GenBank. The PCR product was cloned into cloning expression vestor pGM-T to obtain the cloning expressed plasmid pGM-T-P. After double-digestion by NotI and EcoRI, the product was transferred into prokaryotic expression vetor pET-32a(+)to obtain the prokaryotically expressed plasmid pET-32a-P. The target gene was then expressed in the E.coli BL21(DE3) cell with IPTG induction. The highest expression of target protein was analysed by SDS-PAGE, and the good immunoreactivity to rabies virus antibodies was proved by Western-blot analysis. By using purified protein, the indirect ELISA assay for the detection of rabies virus antibodies in canine serum was applied after management of the optional working condition.

SELECTION OF CITATIONS
SEARCH DETAIL