Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Language
Publication year range
1.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-679678

ABSTRACT

Objective To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus.Methods Six cases with portal vein stenosis of cancerous thrombus,which caused by primary hepatic carcinoma(5 cases)and eholangiocarcinoma(1 case)and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded,were performed percutaneous transhepatie or transsplenic portography.FLUENCY~(TM) endovascular stent-graft(10 mm diameter)was placed at the position of stenosis after gastroesophageal varices embolization.Portal pressure was measured pre-and post-deployment.Results Stents were successfully placed in all patients.The average portal pressure decreased from 50.7 cm H_2O(1 cm H_2O = 0.098 kPa)to 41.3 cm H_2O after endovascular stent-graft deployment.The restenosis were found in 2 cases after one month.Haematemesis and refractory aseites appeared in one case respectively,the other 4 cases showed no significant symptoms above caused by portal hypertension.Conclusion It is safe and feasible for endovaseular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus.Selecting the suitable indications,the symptoms of portal hypertension can be controlled effectively.

SELECTION OF CITATIONS
SEARCH DETAIL
...