Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Micromachines (Basel) ; 15(1)2023 Dec 29.
Article in English | MEDLINE | ID: mdl-38258190

ABSTRACT

The advancement of spatial interaction technology has greatly enriched the domain of consumer electronics. Traditional solutions based on optical technologies suffers high power consumption and significant costs, making them less ideal in lightweight implementations. In contrast, ultrasonic solutions stand out due to their lower power consumption and cost-effectiveness, capturing widespread attention and interest. This paper addresses the challenges associated with the application of ultrasound sensors in spatial localization. Traditional ultrasound systems are hindered by blind spots, large physical dimensions, and constrained measurement ranges, limiting their practical applicability. To overcome these limitations, this paper proposes a miniature ultrasonic spatial localization module employing piezoelectric micromechanical ultrasonic transducers (PMUTs). The module is comprised of three devices each with dimension of 1.2 mm × 1.2 mm × 0.5 mm, operating at a frequency of around 180 kHz. This configuration facilitates a comprehensive distance detection range of 0-800 mm within 80° directivity, devoid of blind spot. The error rate and failure range of measurement as well as their relationship with the SNR (signal-to-noise ratio) are also thoroughly investigated. This work heralds a significant enhancement in hand spatial localization capabilities, propelling advancements in acoustic sensor applications of the meta-universe.

2.
Micromachines (Basel) ; 13(12)2022 Dec 19.
Article in English | MEDLINE | ID: mdl-36557559

ABSTRACT

This paper presents a novel bimorph Piezoelectric Micromachined Ultrasonic Transducer (PMUT) fabricated with 8-inch standard CMOS-compatible processes. The bimorph structure consists of two layers of 20% scandium-doped aluminum nitride (Sc0.2Al0.8N) thin films, which are sandwiched among three molybdenum (Mo) layers. All three Mo layers are segmented to form the outer ring and inner plate electrodes. Both top and bottom electrodes on the outer ring are electrically linked to the center inner plate electrodes. Likewise, the top and bottom center plate electrodes are electrically connected to the outer ring in the same fashion. This electrical configuration maximizes the effective area of the given PMUT design and improves efficiency during the electromechanical coupling process. In addition, the proposed bimorph structure further simplifies the device's electrical layout with only two-terminal connections as reported in many conventional unimorph PMUTs. The mechanical and acoustic measurements are conducted to verify the device's performance improvement. The dynamic mechanical displacement and acoustic output under a low driving voltage (1 Vpp) are more than twice that reported from conventional unimorph devices with a similar resonant frequency. Moreover, the pulse-echo experiments indicate an improved receiving voltage of 10 mV in comparison with the unimorph counterpart (4.8 mV). The validation of device advancement in the electromechanical coupling effect by using highly doped ScAlN thin film, the realization of the proposed bimorph PMUT on an 8-inch wafer paves the path to production of next generation, high-performance piezoelectric MEMS.

3.
Micromachines (Basel) ; 13(11)2022 Nov 15.
Article in English | MEDLINE | ID: mdl-36422408

ABSTRACT

Compared to conventional ultrasonic flowmeters using multiple transducers, this paper reports, for the first time, an airflow volumetric flowmeter using a signal PMUT array to measure the flow rate in a rectangular pipe. The PMUT around 200 kHz is selected to fit the system requirements. All PMUT elements on this single array are then electrically grouped into transmitter and receiver. In order to minimize the crosstalk signal between transmitter and receiver, a phase shift signal is applied at the transmitter to reduce the amplitude of the crosstalk signal by 87.8%, hence, the resultant high sensing resolution. Based on the analog signal extracted from the single PMUT array, a complete flow sensing system is built by using the cross-correlation method and cosine interpolation, whereby the change in flow rate is reflected by the time of flight difference (dTof) recorded at the receiver. Meanwhile, the acoustic path self-calibration is realized by using multiple echoes. Compared with the previously reported MEMS flowmeters with dual or multiple PMUT devices, this paper proposes a single PMUT array flow sensing system, which is able to measure the flow rate changes up to 4 m3/h. With the implementation of a single device, the problem of ultrasound device/reflector misalignment during system setup is completely eradicated.

4.
Micromachines (Basel) ; 13(11)2022 Nov 10.
Article in English | MEDLINE | ID: mdl-36363962

ABSTRACT

Piezoelectric micromachined ultrasonic transducers (PMUTs) have been widely applied in distance sensing. However, the sensing distance of currently reported miniaturized ultrasonic sensors (e.g., PMUTs or CMUT) is still limited up to a certain range (e.g., ≤5 m) compared to conventional bulk ultrasonic devices. This paper reports a PMUT array design using scandium-doped aluminum nitride (AlScN) as its piezoelectric layer for an extended long-range detection purpose. To minimize air attenuation, our device is resonating at 66 kHz for a high receive sensitivity of 5.7 mV/Pa. The proposed PMUT array can generate a sound pressure level (SPL) as high as 120 dB at a distance of 10 cm without beam forming. This PMUT design is catered for a pin-to-pin replacement of the current commercial bulk ultrasonic ranging sensor and works directly with the conventional range finding system (e.g., TI PGA460). In comparison with the common bulk transducer, the size of our device is 80% smaller. With the identical ranging detection setup, the proposed PMUT array improves the system SNR by more than 5 dB even at a distance as far as 6.8 m. The result of extended sensing distance validates our miniaturized PMUT array as the optimized candidate for most ultrasonic ranging applications. With the progressive development of piezoelectric MEMS, we believe that the PMUT technology could be a game changer in future long-range sensing applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...