Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Langmuir ; 35(38): 12543-12549, 2019 09 24.
Article in English | MEDLINE | ID: mdl-31433657

ABSTRACT

This paper reports antifouling properties of nanostructured SiO2 substrates patterned by DNA lithography. We used DNA triangle nanostructures as templates to produce triangular-shaped trenches ca. 130 nm in size on SiO2 surfaces. Using B. subtilis as a bacterial model, we found that such nanopatterned surface showed a 75% reduction in bacterial adhesion and 72% reduction in biofilm density at 35% surface coverage of the nanoscale triangular trenches. DNA-based nanofabrication can produce high-resolution designer patterns, but aligning these patterns has been one of the major technical challenges for its applications in nanoelectronics. This work demonstrates the potential of DNA-based nanofabrication in antifouling applications, where surface patterning of micro/nanostructures is required but not their precise alignment.


Subject(s)
Biofouling/prevention & control , DNA/chemistry , DNA/pharmacology , Nanostructures/chemistry , Silicon Dioxide/chemistry , Bacillus subtilis/drug effects , Bacillus subtilis/physiology , Bacterial Adhesion/drug effects
2.
Beilstein J Nanotechnol ; 8: 2363-2375, 2017.
Article in English | MEDLINE | ID: mdl-29181293

ABSTRACT

We present a method to increase the stability of DNA nanostructure templates through conformal coating with a nanometer-thin protective inorganic oxide layer created using atomic layer deposition (ALD). DNA nanotubes and origami triangles were coated with ca. 2 nm to ca. 20 nm of Al2O3. Nanoscale features of the DNA nanostructures were preserved after the ALD coating and the patterns are resistive to UV/O3 oxidation. The ALD-coated DNA templates were used for a direct pattern transfer to poly(L-lactic acid) films.

3.
Langmuir ; 33(16): 3991-3997, 2017 04 25.
Article in English | MEDLINE | ID: mdl-28406032

ABSTRACT

We report the deposition of DNA origami nanostructures on highly oriented pyrolytic graphite (HOPG). The DNA origami goes through a structural rearrangement and the DNA base is exposed to interact with the graphite surface. Exposure to ambient air, which is known to result in a hydrophilic-to-hydrophobic wetting transition of HOPG, does not significantly impact the deposition yield or the shape deformation of DNA nanostructures. The deposited DNA nanostructures maintain their morphology for at least a week and promote site-selective chemical vapor deposition of SiO2. This process is potentially useful for a range of applications that include but are not limited to nanostructure fabrication, sensing, and electronic and surface engineering.


Subject(s)
DNA/chemistry , Graphite/chemistry , Nanostructures/chemistry , DNA, Single-Stranded/chemistry , Nucleic Acid Conformation , Silicon Dioxide/chemistry , Wettability
4.
Biosens Bioelectron ; 55: 438-45, 2014 May 15.
Article in English | MEDLINE | ID: mdl-24441024

ABSTRACT

We demonstrate a novel fluorescent sensor for real-time and continuous monitoring of the variation of bisulfide in microdialysis effluents by using a nanoparticle-glutathione-fluorescein isothiocyanate (AuNP-GSH-FITC) probe coupled with on-line droplet-based microfluidic chip. The AuNP-GSH-FITC fluorescent probe was firstly developed and used for bisulfide detection in bulk solution by quantitative real-time PCR, which achieved a linear working range from 0.1 µM to 5.0 µM and a limit of detection of ~50 nM. The response time was less than 2 min. With the aid of co-immobilized thiol-polyethylene glycol, the probe exhibited excellent stability and reproducibility in high salinity solutions, including artificial cerebrospinal fluids (aCSF). By adding 0.1% glyoxal to the probe solution, the assay allowed quantification of bisulfide in the presence of cysteine at the micro-molarity level. Using the AuNP-GSH-FITC probe, a droplet-based microfluidic fluorescent sensor was further constructed for online monitoring of bisulfide variation in the effluent of microdialysis. By using fluorescence microscope-charge-coupled device camera as the detector, the integrated microdialysis/microfluidic chip device achieved a detection limit of 2.0 µM and a linear response from 5.0 µM to 50 µM for bisulfide in the tested sample. The method was successfully applied for the on-line measurement of bisulfide variation in aCSF and serum samples. It will be a very useful tool for tracking the variation of bisulfide or hydrogen sulfide in extracellular fluids.


Subject(s)
Biosensing Techniques/instrumentation , Cerebrospinal Fluid/chemistry , Microdialysis/instrumentation , Microfluidic Analytical Techniques/instrumentation , Spectrometry, Fluorescence/instrumentation , Sulfides/blood , Sulfides/cerebrospinal fluid , Equipment Design , Equipment Failure Analysis , Monitoring, Physiologic/instrumentation , Reproducibility of Results , Sensitivity and Specificity
5.
Methods ; 64(3): 255-9, 2013 Dec 15.
Article in English | MEDLINE | ID: mdl-23816791

ABSTRACT

By combination of a modified block PCR and endonuclease IV-based signal amplification system, we have developed a novel approach for ultra-sensitive detection of point mutations. The method can effectively identify mutant target sequence immersed in a large background of wild-type sequences with abundance down to 0.03% (for C→A) and 0.005% (for C→G). This sensitivity is among the highest in comparison with other existing approaches and the operating procedures are simple and time saving. The method holds great potential for future application in clinical diagnosis and biomedical research.


Subject(s)
DNA Mutational Analysis , Deoxyribonuclease IV (Phage T4-Induced)/chemistry , Point Mutation , Base Pairing , Base Sequence , DNA Probes/chemistry , Fluorescent Dyes/chemistry , Humans , Limit of Detection , Molecular Sequence Data , Polymerase Chain Reaction , Transition Temperature
6.
Chem Commun (Camb) ; 49(8): 798-800, 2013 Jan 28.
Article in English | MEDLINE | ID: mdl-23229067

ABSTRACT

A kinetic method has been developed for highly sensitive and selective detection of pyrophosphate anions (PPi) by using a fluorophore labelled single-stranded-DNA-Al(III) complex system. The facile and spectrum-tunable fluorescent sensor enables rapid detection of PPi in urine and cell lysate solutions without the need for complex pre-cleanup procedures.


Subject(s)
Anions/analysis , DNA, Single-Stranded/chemistry , Diphosphates/analysis , Fluorescent Dyes/chemistry , Aluminum/chemistry , Anions/urine , Cell Line , Coordination Complexes/chemistry , Diphosphates/urine , Humans , Kinetics , Sensitivity and Specificity , Spectrometry, Fluorescence/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...