Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Opt Express ; 32(10): 16629-16644, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38858864

ABSTRACT

Differential phase contrast (DPC) imaging relies on computational analysis to extract quantitative phase information from phase gradient images. However, even modest noise level can introduce errors that propagate through the computational process, degrading the quality of the final phase result and further reducing phase sensitivity. Here, we introduce the noise-corrected DPC (ncDPC) to enhance phase sensitivity. This approach is based on a theoretical DPC model that effectively considers most relevant noise sources in the camera and non-uniform illumination in DPC. In particular, the dominating shot noise and readout noise variance can be jointly estimated using frequency analysis and further corrected by block-matching 3D (BM3D) method. Finally, the denoised images are used for phase retrieval based on the common Tikhonov inversion. Our results, based on both simulated and experimental data, demonstrate that ncDPC outperforms the traditional DPC (tDPC), enabling significant improvements in both phase reconstruction quality and phase sensitivity. Besides, we have demonstrated the broad applicability of ncDPC by showing its performance in various experimental datasets.

2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 33(6): 1183-90, 2016 Dec.
Article in Chinese | MEDLINE | ID: mdl-29715417

ABSTRACT

Quantitative assessment of the symptoms of Parkinson's disease is the key for precise diagnosis and treatment and essential for long term management over years.The challenges of quantitative assessment on Parkinson's disease are rich information,ultra-low load,long term and large range monitoring in free-moving condition.In this paper,we developed wearable devices with multiple sensors to monitor and quantify the movement symptoms of Parkinson's disease.Five wearable sensors were used to record motion signals from bilateral forearms,legs and waist.A local area network based on low power Wi-Fi technology was built for long distance wireless data transmission.A software was developed for signal recording and analyzing.The size of each sensor was 39mm×33mm×16mm and the weight was 18 g.The sensors were rechargeable and able to run 12 hours.The wireless transmission radius is about 45 m.The wearable devices were tested in patients and normal subjects.The devices were reliable and accurate for movement monitoring in hospital.


Subject(s)
Monitoring, Ambulatory/instrumentation , Movement , Parkinson Disease/physiopathology , Wearable Electronic Devices , Humans , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...