1.
Br J Radiol ; 89(1060): 20150852, 2016.
Article in English | MEDLINE | ID: mdl-26933911

ABSTRACT

OBJECTIVE: To evaluate the usefulness of two-dimensional quantitative ultrasound shear-wave elastography (2D-SWE) [i.e. virtual touch imaging quantification (VTIQ)] in assessing the ablation zone after radiofrequency ablation (RFA) for ex vivo swine livers. METHODS: RFA was performed in 10 pieces of fresh ex vivo swine livers with a T20 electrode needle and 20-W output power. Conventional ultrasound, conventional strain elastography (SE) and VTIQ were performed to depict the ablation zone 0 min, 10 min, 30 min and 60 min after ablation. On VTIQ, the ablation zones were evaluated qualitatively by evaluating the shear-wave velocity (SWV) map and quantitatively by measuring the SWV. The ultrasound, SE and VTIQ results were compared against gross pathological and histopathological specimens. RESULTS: VTIQ SWV maps gave more details about the ablation zone, the central necrotic zone appeared as red, lateral necrotic zone as green and transitional zone as light green, from inner to exterior, while the peripheral unablated liver appeared as blue. Conventional ultrasound and SE, however, only marginally depicted the whole ablation zone. The volumes of the whole ablation zone (central necrotic zone + lateral necrotic zone + transitional zone) and necrotic zone (central necrotic zone + lateral necrotic zone) measured by VTIQ showed excellent correlation (r = 0.915, p < 0.001, and 0.856, p = 0.002, respectively) with those by gross pathological specimen, whereas both conventional ultrasound and SE underestimated the volume of the whole ablation zone. The SWV values of the central necrotic zone, lateral necrotic zone, transitional zone and unablated liver parenchyma were 7.54-8.03 m s(-1), 5.13-5.28 m s(-1), 3.31-3.53 m s(-1) and 2.11-2.21 m s(-1), respectively (p < 0.001 for all the comparisons). The SWV value for each ablation zone did not change significantly at different observation times within an hour after RFA (all p > 0.05). CONCLUSION: The quantitative 2D-SWE of VTIQ is useful for the depiction of the ablation zone after RFA and it facilitates discrimination of different areas in the ablation zone qualitatively and quantitatively. This elastography technique might be useful for the therapeutic response evaluation instantly after RFA. ADVANCES IN KNOWLEDGE: A new quantitative 2D-SWE (i.e. VTIQ) for evaluation treatment response after RFA is demonstrated. It facilitates discrimination of the different areas in the ablation zone qualitatively and quantitatively and may be useful for the therapeutic response evaluation instantly after RFA in the future.


Subject(s)
Catheter Ablation/methods , Elasticity Imaging Techniques/methods , Liver/diagnostic imaging , Animals , Liver/surgery , Swine
2.
Radiology ; 242(3): 914-24, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17229876

ABSTRACT

PURPOSE: To prospectively investigate whether the ablation zone induced with microwaves could be increased by delivering greater energy with a cooled-shaft antenna. MATERIALS AND METHODS: All studies were animal care and ethics committee approved. Written informed consent was obtained from all patients. Microwave ablation was performed by using a cooled-shaft antenna in 48 ex vivo and 12 in vivo experiments with porcine livers. The coagulation diameters achieved in different microwave ablation parameter groups (60-90 W for 5-25 minutes) were compared. Ninety patients (78 men, 12 women; mean age, 53 years; age range, 20-82 years) with 133 0.8-8.0-cm (mean, 2.7 cm +/- 1.5 [standard deviation]) primary or metastatic liver cancers were treated with the same microwave ablation technique. Complete ablation (CA) and local tumor progression (LTP) rates were determined. Generalized estimating equations were used to compare differences in tumor size, ablation zone diameter, and CA and LTP rates between different patient subgroups. RESULTS: In the ex vivo livers, in vivo livers, and liver cancers, one application of microwave energy with 80 W for 25 minutes produced mean coagulation diameters of 5.6 x 7.4 cm, 3.5 x 5.9 cm, and 3.6 x 5.0 cm, respectively. Skin burn was not observed. CA rates in small (

Subject(s)
Hepatectomy/methods , Liver Neoplasms/pathology , Liver Neoplasms/surgery , Liver/pathology , Liver/surgery , Microwaves/therapeutic use , Adult , Aged , Aged, 80 and over , Animals , Cold Temperature , Female , Humans , Liver/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Male , Middle Aged , Radiography , Swine , Treatment Outcome