Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Total Environ ; 941: 173566, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38823694

ABSTRACT

Desertification poses a severe ecological and environmental challenge in the Mongolian Plateau (MP). It is difficult to quantify desertification distribution using unified indicators in the entire MP, because of its complex physical geographic conditions and various climatic zones covered. To accurately address this challenge, the spatial distribution of desertification at a 30-m resolution from 1990 to 2020 were mapped in this study. The desertification potential occurrence zone was identified by using a moisture index on the MP firstly. The feature space model and five machine learning models were constructed to make the map based on Google Earth Engine and Landsat data. The spatiotemporal distribution of desertification were further analyzed, and the dominant drivers of desertification distribution and evolution were identified using Geodetector model. The results indicate that the potential occurrence area of desertification accounted for 83.88 % of the total land area. The gradient boosted tree model for desertification assessment has the best performance with the highest overall accuracy of 88.18 %. The year 2010 marked a pivotal transition from land degradation to land restoration in the MP. Between 2010 and 2020, desertified land continued to deteriorate extensively in the southern Mongolia, while Inner Mongolia, China, essentially entered a full recovery phase. Precipitation and land use emerged as the primary drivers of the spatial distribution of desertification on the Mongolian Plateau and Mongolia, with potential evapotranspiration and precipitation influencing the distribution of desertification in Inner Mongolia, China. Land use change was the primary driver of desertification evolution on the MP and Mongolia. This study constructs an indicator system and methodology suitable for desertification monitoring on the MP, addresses the lack of refined desertification data over a long time series, and provides scientific reference for decision-making support in combating desertification in this region, and other large arid and semi-arid areas in the world.

2.
Microsyst Nanoeng ; 10: 68, 2024.
Article in English | MEDLINE | ID: mdl-38799404

ABSTRACT

Triboelectric nanogenerators (TENGs) have emerged as a promising approach for generating electricity and providing electrical stimuli in medical electronic devices. Despite their potential benefits, the clinical implementation of TENGs faces challenges such as skin compliance and a lack of comprehensive assessment regarding their biosafety and efficacy. Therefore, further research is imperative to overcome these limitations and unlock the full potential of TENGs in various biomedical applications. In this study, we present a flexible silk fibroin-based triboelectric nanogenerator (SFB-TENG) that features an on-skin substrate and is characterized by excellent skin compliance and air/water permeability. The range of electrical output generated by the SFB-TENG was shown to facilitate the migration and proliferation of Hy926, NIH-3T3 and RSC96 cells. However, apoptosis of fibroblast NIH-3T3 cells was observed when the output voltage increased to more than 20 V at a frequency of 2 Hz. In addition, the moderate electrical stimulation provided by the SFB-TENG promoted the cell proliferation cycle in Hy926 cells. This research highlights the efficacy of a TENG system featuring a flexible and skin-friendly design, as well as its safe operating conditions for use in biomedical applications. These findings position TENGs as highly promising candidates for practical applications in the field of tissue regeneration.

3.
Research (Wash D C) ; 7: 0366, 2024.
Article in English | MEDLINE | ID: mdl-38783913

ABSTRACT

Muscle strength (MS) is related to our neural and muscle systems, essential for clinical diagnosis and rehabilitation evaluation. Although emerging wearable technology seems promising for MS assessment, problems still exist, including inaccuracy, spatiotemporal differences, and analyzing methods. In this study, we propose a wearable device consisting of myoelectric and strain sensors, synchronously acquiring surface electromyography and mechanical signals at the same spot during muscle activities, and then employ a deep learning model based on temporal convolutional network (TCN) + Transformer (Tcnformer), achieving accurate grading and prediction of MS. Moreover, by combining with deep clustering, named Tcnformer deep cluster (TDC), we further obtain a 25-level classification for MS assessment, refining the conventional 5 levels. Quantification and validation showcase a patient's postoperative recovery from level 3.2 to level 3.6 in the first few days after surgery. We anticipate that this system will importantly advance precise MS assessment, potentially improving relevant clinical diagnosis and rehabilitation outcomes.

4.
Sensors (Basel) ; 24(5)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38475142

ABSTRACT

To ensure stable and normal transformer operation, light gas protection of the transformer Buchholz relay is essential. However, false alarms related to light gas protection are common, and troubleshooting them often requires on-site gas sampling by personnel. During this time, the transformer's operating state may rapidly deteriorate, posing a safety threat to field staff. To tackle these challenges, this work presents the near-field, thin-sliced transformer monitoring system that uses Electromagnetic Energy Transmission and Wireless Sensing Device (ETWSD). The system leverages external wireless energy input to power gas monitoring sensors. Simultaneously, it employs Near-Field Communication to obtain real-time concentrations of light gases, along with the electrified state and temperature. In field testing conducted on transformer relays' gas collection chambers, the ETWSD effortlessly monitors parameters within warning ranges, encompassing methane gas concentrations around 1000 ppm, leakage voltage ranging from 0-100 V, and relay working temperatures up to 90 °C. Additionally, to facilitate real-time diagnosis for electrical workers, we have developed an Android-based APP software that displays current light gas concentrations, leakage voltage collection values, and temperature, while also enabling threshold judgment, alarms, and data storage. The developed ETWSD is expected to aid on-site personnel in promptly and accurately evaluating transformer light gas protection error alarm faults. It provides a method for simultaneous, contactless, and rapid monitoring of multiple indicators.

5.
Adv Sci (Weinh) ; 11(17): e2304763, 2024 May.
Article in English | MEDLINE | ID: mdl-38429890

ABSTRACT

Innovative functional electrical stimulation has demonstrated effectiveness in enhancing daily walking and rehabilitating stroke patients with foot drop. However, its lack of precision in stimulating timing, individual adaptivity, and bilateral symmetry, resulted in diminished clinical efficacy. Therefore, a closed-loop wearable device network of intrinsically controlled functional electrical stimulation (CI-FES) system is proposed, which utilizes the personal surface myoelectricity, derived from the intrinsic neuro signal, as the switch to activate/deactivate the stimulation on the affected side. Simultaneously, it decodes the myoelectricity signal of the patient's healthy side to adjust the stimulation intensity, forming an intrinsically controlled loop with the inertial measurement units. With CI-FES assistance, patients' walking ability significantly improved, evidenced by the shift in ankle joint angle mean and variance from 105.53° and 28.84 to 102.81° and 17.71, and the oxyhemoglobin concentration tested by the functional near-infrared spectroscopy. In long-term CI-FES-assisted clinical testing, the discriminability in machine learning classification between patients and healthy individuals gradually decreased from 100% to 92.5%, suggesting a remarkable recovery tendency, further substantiated by performance on the functional movement scales. The developed CI-FES system is crucial for contralateral-hemiplegic stroke recovery, paving the way for future closed-loop stimulation systems in stroke rehabilitation is anticipated.


Subject(s)
Electric Stimulation Therapy , Stroke Rehabilitation , Wearable Electronic Devices , Humans , Stroke Rehabilitation/methods , Stroke Rehabilitation/instrumentation , Male , Middle Aged , Female , Electric Stimulation Therapy/methods , Electric Stimulation Therapy/instrumentation , Aged , Stroke/physiopathology , Stroke/therapy , Walking/physiology , Adult , Equipment Design , Spectroscopy, Near-Infrared/methods
6.
Nano Res ; : 1-9, 2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36785562

ABSTRACT

As extremely important physiological indicators, respiratory signals can often reflect or predict the depth and urgency of various diseases. However, designing a wearable respiratory monitoring system with convenience, excellent durability, and high precision is still an urgent challenge. Here, we designed an easy-fabricate, lightweight, and badge reel-like retractable self-powered sensor (RSPS) with high precision, sensitivity, and durability for continuous detection of important indicators such as respiratory rate, apnea, and respiratory ventilation. By using three groups of interdigital electrode structures with phase differences, combined with flexible printed circuit boards (FPCBs) processing technology, a miniature rotating thin-film triboelectric nanogenerator (RTF-TENG) was developed. Based on discrete sensing technology, the RSPS has a sensing resolution of 0.13 mm, sensitivity of 7 P·mm-1, and durability more than 1 million stretching cycles, with low hysteresis and excellent anti-environmental interference ability. Additionally, to demonstrate its wearability, real-time, and convenience of respiratory monitoring, a multifunctional wearable respiratory monitoring system (MWRMS) was designed. The MWRMS demonstrated in this study is expected to provide a new and practical strategy and technology for daily human respiratory monitoring and clinical diagnosis. Electronic Supplementary Material: Supplementary material (additional figures and movies, including the production process of respiratory monitoring straps, the mechanical analysis of RSPS, RTF-TENG versus vector TENG sensors, the simulation studies of TE-TENG and FT-TENG, the additional characterization of RTF-TENG, the tensile and robustness tests of RSPS, the characterizations of the MWRMS during different sleeping positions, detailed circuit schematic of the MWRMS, the displacements and phase relations of RSPS, MWRMS for multifunctional respiratory monitoring) is available in the online version of this article at 10.1007/s12274-023-5420-1.

7.
Nanoscale ; 15(6): 2820-2827, 2023 Feb 09.
Article in English | MEDLINE | ID: mdl-36688256

ABSTRACT

Effective power management on the outputs of triboelectric nanogenerators (TENGs) is critical for their practical applications due to the large impedance and unbalanced load matching. Recently proposed voltage multiplying circuits for external-charge excitation and self-charge excitation are usually unstable and require reversal for device restarting and common switched-capacitor-converters usually cause large switching losses. In this work, we fabricated a fractal structured charge-excitation circuit for TENGs using diodes and capacitors. The fractal switched-capacitor-converter coupled with voltage regulator diodes can greatly boost the output charge and current of the TENG without reverse starting. The managed output performance of the TENG can be controlled by the electronic component parameters and external operating frequency. Through the component and condition optimization, the fractal structured charge-excitation TENG (FSC-TENG) can achieve nearly 5.8 times charge boosting and almost 16.8 times power boosting in the pulsed mode. Furthermore, the FSC-TENG successfully drove a hygrothermograph and was integrated into a yoga mat for harvesting human-body motion energy to power an electronic watch and a pedometer. The FSC-TENG with good charge accumulation properties and stability is a promising candidate for practical self-powered applications.

8.
Adv Sci (Weinh) ; 9(35): e2204407, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36253135

ABSTRACT

Triboelectric nanogenerators (TENGs) to harvest ocean wave blue energy is flourishing, yet the research horizon has been limited to centimeter-level TENG. Here, for the first time, a TENG shell is advanced for ocean energy harvesting to 0.5 m and an excellent frictional areal density of 1.03 cm-1 and economies of scale are obtained. The unique structure of the multi-arch shape is adopted to untie the difficulty of fully getting the extensive friction layer contact. An inside steel plate is vertically placed in the center of every TENG block, which can activate the TENG to achieve complete contact even at a tilt angle of 7 degrees. The proposed half-meter TENG (HM-TENG) has a broad response band from 0.1 to 2 Hz, a total transferred charge quantity up to 67.2 µC, and one single TENG can deliver an open-circuit voltage of 368 V. Coupled with the self-stabilizing and susceptible features the ellipsoid shell brings, the HM-TENG can readily accommodate itself to the all-weather, all-sea wave energy harvesting. Muchmore, the HM-TENG is also applied to RF signal transmitters. This work takes the first step toward near-meter-scale enclosures and provides a new direction for large-scale wave energy harvesting.

SELECTION OF CITATIONS
SEARCH DETAIL
...