Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Quant Imaging Med Surg ; 13(12): 8587-8598, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38106337

ABSTRACT

Background: Ultrasonography of the uterine artery (UtA) in the first and second trimesters of pregnancy can assess uterine-placental blood perfusion and guide early clinical prevention. Establishing normal ranges of the UtA pulsatility index (UtA-PI) at 11-14 weeks of pregnancy is helpful for the early identification of high-risk pregnant women and improving the prognosis. This study aimed to establish a reference range of UtA-PI based on crown-rump length (CRL) for spontaneous and in vitro fertilization (IVF) singleton pregnancy during 11-14 weeks, respectively. Methods: A prospective study was performed at Peking Union Medical College Hospital. Healthy, low-risk women with a singleton pregnancy at 11-14 gestational weeks were consecutively recruited for this study from December 2017 to December 2020. All participants underwent routine prenatal ultrasound examination. The CRL of the fetus and the UtA-PI were measured in both uterine arteries, and average values were calculated. The LMS method was used to fit the percentile (P)5, P10, P25, P50, P75, P90, and P95 curves of the UtA-PI value of spontaneous and IVF singleton pregnancy with CRL changes, respectively. Results: A total of 1,962 pregnant women with normal fetuses were included in this study, including 1,792 pregnancies conceived naturally and 170 IVF fetuses. The UtA-PI reference range in the spontaneous pregnancy group was consistently higher than that in the IVF group during 11-14 weeks, and showed a statistically significant difference in UtA-PI for spontaneous and IVF pregnancies (P<0.001). According to the LMS method, each percentile curve of UtA-PI decreased with the increase of CRL in both the natural pregnancy group and the IVF group. The P95 range of UtA-PI for pregnant women with naturally conceived and IVF pregnancy was 2.74 to 2.11 and 2.50 to 1.94, respectively. The overall change of UtA-PI differentials of the two groups showed a downward trend and decreased slightly with the increase of CRL. Conclusions: This study provided a single-center, large sample of data and constructed a CRL-based reference value of UtA-PI for spontaneous and IVF singleton pregnancy, which provides a reliable basis for early UtA evaluation and early clinical decision-making during 11-14 gestational weeks.

2.
Emerg Microbes Infect ; 11(1): 1910-1919, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35686572

ABSTRACT

Waning of neutralizing titres along with decline of protection efficacy after the second dose of COVID-19 vaccines was observed, including China-made inactivated vaccines. Efficacy of a heterologous boosting using one dose of a recombinant SARS-CoV-2 fusion protein vaccine (V-01) in inactivated vaccine-primed population was studied, aimed to restore the immunity. A randomized, double-blind and placebo-controlled phase III trial was conducted in healthy people aged 18 years or older in Pakistan and Malaysia. Each eligible participant received one dose of the V-01 vaccine developed by Livzon Mabpharm Inc. or placebo within the 3-6 months after the two-dose primary regimen, and was monitored for safety and efficacy. The primary endpoint was protection against confirmed symptomatic SARS-CoV-2 infection. A total of 10,218 participants were randomly assigned to receive a vaccine or placebo. Virus-neutralizing antibodies were assessed in 419 participants. A dramatic increase (11.3-fold; 128.3-1452.8) of neutralizing titres was measured in the V-01 group at 14 days after the booster. Over two months of surveillance, vaccine efficacy was 47.8% (95%CI: 22.6-64.7) according to the intention-to-treat principle. The most common adverse events were transient, mild-to-moderate pain at the injection site, fever, headache, and fatigue. Serious adverse events occurred almost equally in V-01 (0.12%) and placebo (0.16%) groups. The heterologous boosting with the V-01 vaccine was safe and efficacious, which could elicit robust humoral immunity under the epidemic of the Omicron variant.Trial registration: ClinicalTrials.gov identifier: NCT05096832.


Subject(s)
COVID-19 Vaccines , COVID-19 , Immunization, Secondary , SARS-CoV-2 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines/immunology , Humans , Immunogenicity, Vaccine , Interferons , Recombinant Fusion Proteins/genetics , Vaccines, Inactivated
3.
Chin Med J (Engl) ; 134(16): 1967-1976, 2021 07 22.
Article in English | MEDLINE | ID: mdl-34310400

ABSTRACT

BACKGROUND: Innovative coronavirus disease 2019 (COVID-19) vaccines, with elevated global manufacturing capacity, enhanced safety and efficacy, simplified dosing regimens, and distribution that is less cold chain-dependent, are still global imperatives for tackling the ongoing pandemic. A previous phase I trial indicated that the recombinant COVID-19 vaccine (V-01), which contains a fusion protein (IFN-PADRE-RBD-Fc dimer) as its antigen, is safe and well tolerated, capable of inducing rapid and robust immune responses, and warranted further testing in additional clinical trials. Herein, we aimed to assess the immunogenicity and safety of V-01, providing rationales of appropriate dose regimen for further efficacy study. METHODS: A randomized, double-blind, placebo-controlled phase II clinical trial was initiated at the Gaozhou Municipal Centre for Disease Control and Prevention (Guangdong, China) in March 2021. Both younger (n = 440; 18-59 years of age) and older (n = 440; ≥60 years of age) adult participants in this trial were sequentially recruited into two distinct groups: two-dose regimen group in which participants were randomized either to follow a 10 or 25 µg of V-01 or placebo given intramuscularly 21 days apart (allocation ratio, 3:3:1, n = 120, 120, 40 for each regimen, respectively), or one-dose regimen groups in which participants were randomized either to receive a single injection of 50 µg of V-01 or placebo (allocation ratio, 3:1, n = 120, 40, respectively). The primary immunogenicity endpoints were the geometric mean titers of neutralizing antibodies against live severe acute respiratory syndrome coronavirus 2, and specific binding antibodies to the receptor binding domain (RBD). The primary safety endpoint evaluation was the frequencies and percentages of overall adverse events (AEs) within 30 days after full immunization. RESULTS: V-01 provoked substantial immune responses in the two-dose group, achieving encouragingly high titers of neutralizing antibody and anti-RBD immunoglobulin, which peaked at day 35 (161.9 [95% confidence interval [CI]: 133.3-196.7] and 149.3 [95%CI: 123.9-179.9] in 10 and 25 µg V-01 group of younger adults, respectively; 111.6 [95%CI: 89.6-139.1] and 111.1 [95%CI: 89.2-138.4] in 10 and 25 µg V-01 group of older adults, respectively), and remained high at day 49 after a day-21 second dose; these levels significantly exceed those in convalescent serum from symptomatic COVID-19 patients (53.6, 95%CI: 31.3-91.7). Our preliminary data show that V-01 is safe and well tolerated, with reactogenicity predominantly being absent or mild in severity and only one vaccine-related grade 3 or worse AE being observed within 30 days. The older adult participants demonstrated a more favorable safety profile compared with those in the younger adult group: with AEs percentages of 19.2%, 25.8%, 17.5% in older adults vs. 34.2%, 23.3%, 26.7% in younger adults at the 10, 25 µg V-01 two-dose group, and 50 µg V-01 one-dose group, respectively. CONCLUSIONS: The vaccine candidate V-01 appears to be safe and immunogenic. The preliminary findings support the advancement of the two-dose, 10 µg V-01 regimen to a phase III trial for a large-scale population-based evaluation of safety and efficacy. TRIAL REGISTRATION: http://www.chictr.org.cn/index.aspx (No. ChiCTR2100045107, http://www.chictr.org.cn/showproj.aspx?proj=124702).


Subject(s)
COVID-19 , Aged , Antibodies, Viral , COVID-19/therapy , COVID-19 Vaccines , Double-Blind Method , Humans , Immunization, Passive , Recombinant Fusion Proteins , SARS-CoV-2 , COVID-19 Serotherapy
4.
Chin Med J (Engl) ; 130(14): 1722-1730, 2017 Jul 20.
Article in English | MEDLINE | ID: mdl-28685724

ABSTRACT

OBJECTIVE: Contrast-enhanced ultrasound (CEUS) is a well-established imaging modality which has been put into clinical use in recent years with the development of second-generation contrast agent and imaging devices, and its applications in the assessment of inflammatory arthritis, such as rheumatoid arthritis, psoriatic arthritis, and ankylosing spondylitis, have provoked abundant discussion and researches among radiologists and rheumatologists. To summarize the achievements of clinical studies on CEUS in the application of arthritis, and to keep up with the latest progresses of the imaging technique, we reviewed the literature in recent years, hoping to establish the role of CEUS in joint diseases. DATA SOURCES: PubMed and EMBASE. STUDY SELECTION: We searched the database with the conditions "contrast-enhanced ultrasound AND arthritis" with the time limitation of recent 10 years. Clinical studies applying CEUS in inflammatory arthritis and review articles about development of CEUS in joint diseases in English were selected. RESULTS: As it is proved by most studies in recent years, by delineating microvasculature within the inflamed joints, CEUS can indicate early arthritis with high sensitivity and specificity. Moreover, the imaging of CEUS has been proved to be consistent with histopathological changes of inflammatory arthritis. Quantitative analysis of CEUS permits further evaluation of disease activity. CEUS also plays a significant role in the therapeutic monitoring of the disease, which has been backed up by a number of studies. CONCLUSIONS: CEUS may be a new choice for the rheumatologists to evaluate inflammatory arthritis, because of its low price, ability to provide dynamic pictures, and high sensitivity to angiogenesis. It can also be applied in disease classification and therapeutic monitoring. More studies about CEUS need to be done to set up the diagnostic standards.


Subject(s)
Arthritis, Rheumatoid/diagnostic imaging , Ultrasonography/methods , Contrast Media/analysis , Humans
5.
Huan Jing Ke Xue ; 35(4): 1602-12, 2014 Apr.
Article in Chinese | MEDLINE | ID: mdl-24946623

ABSTRACT

Cr(VI) has been causing serious environmental pollution due to its carcinogenicity, teratogenicity and strong migration. Reduction of Cr( VI) to Cr(III), a precipitation that is much less toxic, is an efficient strategy to control Cr pollution. Within the strategy, bacterial reduction of Cr(VI) to Cr(III) has been considered as one of the best bioremediation methods because of its efficiency, environment friendly, and low cost; however, the molecular mechanism remains large unknown. This review summarizes Cr(VI) reduction bacterial species and its application in pollution control, elaborates the pathways of Cr( VI) reduction and functional proteins involved, concludes the molecular mechanism of baterial reduction Cr(VI), and discusses the orientation of the future research.


Subject(s)
Bacteria/metabolism , Chromium/chemistry , Environmental Pollution/analysis , Biodegradation, Environmental
6.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 35(2): 140-4, 2013 Apr.
Article in Chinese | MEDLINE | ID: mdl-23643000

ABSTRACT

OBJECTIVE: To summarize the sonographic features of the lymphoma in the abdominal lymph nodes. METHOD: The clinical data and sonographic findings of 41 lymphoma patients with original appearance of abdominal mass or lymphadenectasis were retrospectively analyzed. RESULTS: Among these 41 cases, the retroperitoneal and mesenteric lymph nodes were most commonly involved.These patients were divided into two types according to sonographic appearances:solitary mass(n=14) and multiple nodules(n=27) .Solitary hypoechoic mass in abdomen was found in the former type, mostly with irregular or lobular shape, and the inner echo was often heterogenous.The typical appearances of the latter type were multiple enlarged lymph nodes, mostly round or oval, with homogeneous inner echo and clear margins.Some other sonographic characteristics were also helpful for the diagnosis of lymphoma, such as cobblestone sign, intranodular reticulation, vessels-embedded sign, and hilar vascularity. CONCLUSION: Ultrasonography can provide useful information in the diagnosis of the lymphoma in the abdominal lymph nodes.


Subject(s)
Abdominal Neoplasms/diagnostic imaging , Lymph Nodes/diagnostic imaging , Lymphoma/diagnostic imaging , Adult , Aged , Female , Humans , Male , Middle Aged , Retrospective Studies , Ultrasonography , Young Adult
7.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 35(1): 69-73, 2013 Feb.
Article in Chinese | MEDLINE | ID: mdl-23469794

ABSTRACT

OBJECTIVE: To explore the sonographic characteristics of intraveous leiomyomatosis (IVL) with intracardiac extension and improve its diagnosis. METHODS: The clinical and sonographic data of 13 female patients with pathologically confirmed IVL with intracardiac extension who were treated in our hospital between 2002 and 2012 were retrospectively analyzed. These patients aged 44 years old (range: 38-49 years), and 10 of them were first-episode patients and the remaining 3 were recurrent patients. Eight patients had a history of hysterectomy for leiomyoma. RESULTS: The first-episode symptoms included exertional chest tightness and shortness of breath (n=5), abdominal distention and edema of low extermity (n=4), exertional palpitation of cardiac origin (n=3), and menorrhagia (n=1). Ultrasonography showed that all patients had isoechoic or hypoechoic tumors extended through the inferior vena cava into right heart chambers (62% in right atrium alone and 38% in right ventricle and atrium). Nine masses in right heart chamber (69.2%) were oval and 4 (30.8%) were serpentine, which were all with well-demarcated borders and most (80%) with heteroechogenic texture. Ten patients had hypoechoic or mixed echoic tumors in pelvic cavity or uterus, and 6 of them had abundant blood flow. CONCLUSIONS: IVL with intracardiac extension has certain sonographic characteristics. Ultrasonography is a valuable tool in the diagnosis of IVL with intracardiac extension.


Subject(s)
Leiomyomatosis/diagnostic imaging , Myocardium/pathology , Vascular Neoplasms/diagnostic imaging , Adult , Female , Humans , Leiomyomatosis/pathology , Middle Aged , Retrospective Studies , Ultrasonography , Vascular Neoplasms/pathology
8.
J Ultrasound Med ; 31(5): 747-55, 2012 May.
Article in English | MEDLINE | ID: mdl-22535722

ABSTRACT

OBJECTIVES: The purpose of this study was to investigate the influence of atherosclerosis and age on 4 representative Doppler parameters in the diagnosis of renal artery stenosis. METHODS: The 4 parameters, renal peak systolic velocity (PSV), renal-aortic ratio, renal-interlobar ratio, and acceleration time, were measured in 208 patients before angiography. The 208 patients were divided into groups according to age and atherosclerosis stratification. The Student t test, 1-way analysis of variance, and the χ(2) test were used to compare all 4 parameters and clinical characteristics. The optimal cutoff values were determined by receiver operating characteristic curves. The diagnostic concordance between atherosclerosis and age strata was evaluated by the Cohen κ coefficient. RESULTS: Of the 416 renal arteries shown on Doppler sonography, 204 had a diagnosis of renal artery stenosis and 19 as occlusion on angiography. The optimal cutoff values for the renal-aortic ratio and renal-interlobar ratio in the groups aged 46 years or older and younger than 46 years were much different (2.3 versus 1.4 and 5.1 versus 6.5, respectively), whereas those for the renal PSV and acceleration time were close to each other or the same (170 versus 180 cm/s and 51 versus 51 milliseconds). The κ coefficients for the renal PSV, renal-interlobar ratio, acceleration time, and renal-aortic ratio between the atherosclerosis and age strata were 0.93, 0.99, 1.00, and 0.71. CONCLUSIONS: Atherosclerosis and age show comparable influences on Doppler parameters in the diagnosis of renal artery stenosis. For clinical convenience, cutoff values may be separately established on the basis of a 46-year-old borderline for the renal-aortic ratio and renal-interlobar ratio, although this process is not necessary for the renal PSV and acceleration time.


Subject(s)
Atherosclerosis/complications , Atherosclerosis/diagnostic imaging , Renal Artery Obstruction/diagnostic imaging , Renal Artery Obstruction/etiology , Ultrasonography, Doppler , Adolescent , Adult , Aged , Aged, 80 and over , Angiography , Area Under Curve , Chi-Square Distribution , Child , Female , Humans , Male , Middle Aged , ROC Curve
9.
Chin Med Sci J ; 25(3): 151-5, 2010 Sep.
Article in English | MEDLINE | ID: mdl-21180276

ABSTRACT

OBJECTIVE: To analyze the clinical and ultrasonographic imaging features of intraductal papillary mucinous neoplasm (IPMN) of the pancreas. METHODS: Twelve patients with IPMN underwent surgery between May 2005 and December 2008, including 4 (33.3%) with adenoma and 8 (66.7%) with adenocarcinoma. IPMN was classified preoperatively into 3 types based on sonographic findings of different sites: main duct, branch duct, and combined type. All clinical presentations and ultrasonographic findings of those patients were reviewed and the correlation between ultrasonographic findings and histopathological results was analyzed. RESULTS: There were 9 men and 3 women with a mean age of 60.1 +/- 9.6 years (range, 32-73). Of all the 12 patients with IPMN, 9 (75.0%) had experienced some symptoms of epigastric discomfort and/or pain as well as backache; 7 cases were with medical history of acute pancreatitis, 5 cases with diabetes, 4 cases with elevated CA19-9, and 2 cases with steatorrhea. All lesions of IPMN have been revealed by transabdominal ultrasonography. The mean diameters of the lesions were 1.4 +/- 0.8 cm (range, 0.5-2.0) and 6.3 +/- 6.0 cm (range, 2.0-20.0) in adenomas and adenocarcinomas, respectively. And the mean diameters of the main duct in adenomas and adenocarcinomas were 1.0 +/- 0.8 cm and 1.6 +/- 1.0 cm, respectively. Among the 4 adnomas, 3 (75.0%) cases were classified as branch type based on sonographic findings, and 2 were demonstrated as mural nodules in which no color signals was detected. Among the 8 adenocarcinomas, 5 (62.5%) cases were classified as main duct type, and 3 (37.5%) as combined type. In 7 of the 8 adenocarcinomas, mural nodules were detected within the dilated ducts or cysts of the lesions in which color flow signals were detected. CONCLUSIONS: Transabdominal ultrasonography can reveal the pancreatic cystic lesions of IPMN as well as dilated pancreatic ducts. Some characteristics should be noticed as suggesting the possibility of malignancy: clinical symptoms of pancreatic insufficiency, large tumor size, and mural nodules with color Doppler flow signals. Transabdominal ultrasonography could be a useful tool to help diagnose and make appropriate management of IPMN.


Subject(s)
Adenocarcinoma, Mucinous/diagnostic imaging , Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Papillary/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Adult , Aged , Female , Humans , Male , Middle Aged , Pancreatic Cyst/diagnostic imaging , Ultrasonography
10.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(3): 595-8, 2010 Mar.
Article in Chinese | MEDLINE | ID: mdl-20496667

ABSTRACT

The electroluminescence effect can be observed by the micro N-type wide-gap CBN semiconductor crystal under the condition of static eletric field. The micro N-type CBN crystal was fixed on the focus of the parabolic reflector of grating monochromator, and the maximum value of transmission ratio and the ideal signal-noise ratio can be obtained. Under the condition of static ectric-field intensity (4.7 x 10(6) V x cm(-1)), the blue-violet light-emitting spectrum of the CBN crystal was measured in the range from 350 to 450 nm. The construction of the CBN energy band, which was calculated with the First-principles method, the nonlinear relationship between current density and the ectric-field intensity that was measured and the phenomenon of electrical break-down were considered together to enable us to discuss the luminescence mechanism. Finally, the authors came up with the luminescence mechanism concerning electron migration from gamma energy valley to X energy valley. The large number of excited electrons we talked about were generated by polarization and breakdown of defect dipole before avalanche breakdown occurred.

11.
Clin Imaging ; 32(5): 367-71, 2008.
Article in English | MEDLINE | ID: mdl-18760724

ABSTRACT

OBJECTIVE: This study aimed to evaluate the value of color Doppler sonography (CDS) in the diagnosis of acute renal artery thrombosis or embolism (ARATE). METHODS: We retrospectively reviewed the CDS findings of 10 patients with ARATE, which were confirmed by the clinical data and digital subtraction angiography or computed tomography (n=8) or by the results of surgical pathology (n=2). We analyzed the echogenicity and size of the kidneys on gray-scale images and blood flow parameters of the main renal artery, renal vein, and the intrarenal artery (segmental or interlobar artery) of the kidneys on CDS in all cases. RESULTS: Four patients with acute main renal artery thrombosis (two transplanted kidneys and two native kidneys) correctly detected by CDS underwent emergency thrombolysis via renal artery. The results of CDS in six native kidneys with renal artery embolism included two cases with satisfactory CDS demonstrations, two cases with undetermined CDS findings, one case interpreted as severe renal artery stenosis, and one misdiagnosed case. CONCLUSIONS: CDS is a useful imaging tool in the diagnosis of large renal infarcts caused by thrombosis or embolism in the main renal artery. However, small infarcts, which need other imaging modalities for further evaluation and confirmation, may be neglected by CDS.


Subject(s)
Embolism/diagnostic imaging , Renal Artery Obstruction/diagnostic imaging , Thrombosis/diagnostic imaging , Ultrasonography, Doppler, Color/methods , Acute Disease , Adult , Angiography, Digital Subtraction/methods , Embolism/complications , Female , Humans , Male , Middle Aged , Renal Artery Obstruction/etiology , Reproducibility of Results , Retrospective Studies , Risk Factors , Sensitivity and Specificity , Thrombosis/complications , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...