Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 95(5)2024 May 01.
Article in English | MEDLINE | ID: mdl-38727574

ABSTRACT

A pulsed power supply with a short rise time and high repetition frequency is favorable to driving diffusive plasma for strongly oxidizing radical (O3, OH) generation and increasing the system's energy efficiency. In this paper, a 10-stage solid-state linear transformer driver (LTD) with a nanosecond rise time is developed to drive plasma for wastewater treatment. To decrease the rise time, a control system with low jitter is developed to improve the synchronization of pulses using an optocoupler isolation chip. A 10-stage LTD with a rise time of 6.2 ns is realized in the case that the rise time of the single-stage LTD is 5.4 ns. The results show that the LTD can generate pulses on a 300 Ω resistive load with a repetition frequency of 10 kHz, an amplitude of 8.80 kV, an overshoot less than 3.97%, and a reverse overshoot less than 4.82%. The rise time (6.2-33.0 ns), the pulse width (35.9-200.0 ns), and the fall time (10.5-27.6 ns) can be adjusted flexibly and independently by controlling the drive signals of metal oxide semiconductor field effect transistors. The pulsed generator is utilized to drive plasma in the needle-water electrode system. The preliminary experimental results show that the plasma includes abundant oxygen atoms and hydroxyl radicals with high activity, and it is suitable for wastewater treatment.

2.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38214592

ABSTRACT

The Blumlein pulse forming network (PFN) has widely been used in pulsed power technology to generate square waves with short pulse widths. In this paper, we developed a repetitive frequency square wave generator based on Blumlein PFN and pseudospark switch (PSS). A Blumlein PFN with unequal capacitances has been proposed, and the PFN parameters have been optimized for better output waveforms. A single-gap PSS with a withstand voltage of 40 kV and a repetitive frequency of 100 Hz has been designed to switch the Blumlein PFN. The experiment results show that the square wave generator can output pulses with a voltage of 26 kV, a rise time of 25 ns, and a pulse width of 90 ns on a matched load of 11 Ω. It has operated steadily for 10 h with a repetitive frequency of 100 Hz, and the jitter remains at around 1 ns after 1.05 × 106 shots.

SELECTION OF CITATIONS
SEARCH DETAIL
...