1.
J Med Signals Sens ; 10(4): 228-238, 2020.
Article in English | MEDLINE | ID: mdl-33575195

ABSTRACT

BACKGROUND: A simple data collection approach based on electroencephalogram (EEG) measurements has been proposed in this study to implement a brain-computer interface, i.e., thought-controlled wheelchair navigation system with communication assistance. METHOD: The EEG signals are recorded for seven simple tasks using the designed data acquisition procedure. These seven tasks are conceivably used to control wheelchair movement and interact with others using any odd-ball paradigm. The proposed system records EEG signals from 10 individuals at eight-channel locations, during which the individual executes seven different mental tasks. The acquired brainwave patterns have been processed to eliminate noise, including artifacts and powerline noise, and are then partitioned into six different frequency bands. The proposed cross-correlation procedure then employs the segmented frequency bands from each channel to extract features. The cross-correlation procedure was used to obtain the coefficients in the frequency domain from consecutive frame samples. Then, the statistical measures ("minimum," "mean," "maximum," and "standard deviation") were derived from the cross-correlated signals. Finally, the extracted feature sets were validated through online sequential-extreme learning machine algorithm. RESULTS AND CONCLUSION: The results of the classification networks were compared with each set of features, and the results indicated that µ (r) feature set based on cross-correlation signals had the best performance with a recognition rate of 91.93%.

2.
Comput Methods Programs Biomed ; 155: 39-51, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29512503

ABSTRACT

BACKGROUND AND OBJECTIVE: Infant cry signal carries several levels of information about the reason for crying (hunger, pain, sleepiness and discomfort) or the pathological status (asphyxia, deaf, jaundice, premature condition and autism, etc.) of an infant and therefore suited for early diagnosis. In this work, combination of wavelet packet based features and Improved Binary Dragonfly Optimization based feature selection method was proposed to classify the different types of infant cry signals. METHODS: Cry signals from 2 different databases were utilized. First database contains 507 cry samples of normal (N), 340 cry samples of asphyxia (A), 879 cry samples of deaf (D), 350 cry samples of hungry (H) and 192 cry samples of pain (P). Second database contains 513 cry samples of jaundice (J), 531 samples of premature (Prem) and 45 samples of normal (N). Wavelet packet transform based energy and non-linear entropies (496 features), Linear Predictive Coding (LPC) based cepstral features (56 features), Mel-frequency Cepstral Coefficients (MFCCs) were extracted (16 features). The combined feature set consists of 568 features. To overcome the curse of dimensionality issue, improved binary dragonfly optimization algorithm (IBDFO) was proposed to select the most salient attributes or features. Finally, Extreme Learning Machine (ELM) kernel classifier was used to classify the different types of infant cry signals using all the features and highly informative features as well. RESULTS: Several experiments of two-class and multi-class classification of cry signals were conducted. In binary or two-class experiments, maximum accuracy of 90.18% for H Vs P, 100% for A Vs N, 100% for D Vs N and 97.61% J Vs Prem was achieved using the features selected (only 204 features out of 568) by IBDFO. For the classification of multiple cry signals (multi-class problem), the selected features could differentiate between three classes (N, A & D) with the accuracy of 100% and seven classes with the accuracy of 97.62%. CONCLUSION: The experimental results indicated that the proposed combination of feature extraction and selection method offers suitable classification accuracy and may be employed to detect the subtle changes in the cry signals.


Subject(s)
Algorithms , Crying , Wavelet Analysis , Asphyxia/physiopathology , Databases, Factual , Deafness/physiopathology , Humans , Hunger , Infant , Jaundice/physiopathology , Machine Learning , Neural Networks, Computer , Nonlinear Dynamics , Pain/physiopathology , Reproducibility of Results , Signal Processing, Computer-Assisted
3.
Sensors (Basel) ; 15(9): 21710-45, 2015 Aug 31.
Article in English | MEDLINE | ID: mdl-26404288

ABSTRACT

Parkinson's Disease (PD) is characterized as the commonest neurodegenerative illness that gradually degenerates the central nervous system. The goal of this review is to come out with a summary of the recent progress of numerous forms of sensors and systems that are related to diagnosis of PD in the past decades. The paper reviews the substantial researches on the application of technological tools (objective techniques) in the PD field applying different types of sensors proposed by previous researchers. In addition, this also includes the use of clinical tools (subjective techniques) for PD assessments, for instance, patient self-reports, patient diaries and the international gold standard reference scale, Unified Parkinson Disease Rating Scale (UPDRS). Comparative studies and critical descriptions of these approaches have been highlighted in this paper, giving an insight on the current state of the art. It is followed by explaining the merits of the multiple sensor fusion platform compared to single sensor platform for better monitoring progression of PD, and ends with thoughts about the future direction towards the need of multimodal sensor integration platform for the assessment of PD.


Subject(s)
Biomedical Technology/methods , Motor Disorders/diagnosis , Motor Disorders/physiopathology , Parkinson Disease/diagnosis , Parkinson Disease/physiopathology , Accelerometry , Humans , Monitoring, Physiologic , Motor Disorders/complications , Parkinson Disease/complications
4.
PLoS One ; 10(3): e0120344, 2015.
Article in English | MEDLINE | ID: mdl-25799141

ABSTRACT

In the recent years, many research works have been published using speech related features for speech emotion recognition, however, recent studies show that there is a strong correlation between emotional states and glottal features. In this work, Mel-frequency cepstralcoefficients (MFCCs), linear predictive cepstral coefficients (LPCCs), perceptual linear predictive (PLP) features, gammatone filter outputs, timbral texture features, stationary wavelet transform based timbral texture features and relative wavelet packet energy and entropy features were extracted from the emotional speech (ES) signals and its glottal waveforms(GW). Particle swarm optimization based clustering (PSOC) and wrapper based particle swarm optimization (WPSO) were proposed to enhance the discerning ability of the features and to select the discriminating features respectively. Three different emotional speech databases were utilized to gauge the proposed method. Extreme learning machine (ELM) was employed to classify the different types of emotions. Different experiments were conducted and the results show that the proposed method significantly improves the speech emotion recognition performance compared to previous works published in the literature.


Subject(s)
Emotions , Phonetics , Speech Recognition Software
5.
Australas Phys Eng Sci Med ; 37(2): 439-56, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24691930

ABSTRACT

Wavelet theory is emerging as one of the prevalent tool in signal and image processing applications. However, the most suitable mother wavelet for these applications is still a relative question mark amongst researchers. Selection of best mother wavelet through parameterization leads to better findings for the analysis in comparison to random selection. The objective of this article is to compare the performance of the existing members of mother wavelets and to select the most suitable mother wavelet for accurate infant cry classification. Optimal wavelet is found using three different criteria namely the degree of similarity of mother wavelets, regularity of mother wavelets and accuracy of correct recognition during classification processes. Recorded normal and pathological infant cry signals are decomposed into five levels using wavelet packet transform. Energy and entropy features are extracted at different sub bands of cry signals and their effectiveness are tested with four supervised neural network architectures. Findings of this study expound that, the Finite impulse response based approximation of Meyer is the best wavelet candidate for accurate infant cry classification analysis.


Subject(s)
Crying/physiology , Neural Networks, Computer , Wavelet Analysis , Databases, Factual , Humans , Infant
6.
Biomed Tech (Berl) ; 59(3): 241-9, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24402883

ABSTRACT

Emotional intelligence is one of the key research areas in human-computer interaction. This paper reports the development of an emotion recognition system using facial electromyogram (EMG) signals focusing the ambiguity on the frequency ranges used by different research works. The six emotional states (happiness, sadness, fear, surprise, disgust, and neutral) were elicited in 60 subjects using audio visual stimuli. Statistical features were extracted from the signals at high, medium, low, and very low frequency levels. They were then classified using four classifiers - naïve Bayes, regression tree, K-nearest neighbor, and fuzzy K-nearest neighbor, and the performance of the system at the different frequency levels were studied using three metrics, namely, % accuracy, sensitivity, and specificity. The post hoc tests in analysis of variance (ANOVA) indicate that the features contain significant emotional information at the very low-frequency range (<0.08 Hz). Similarly, the performance metrics of the classifiers also ensure better recognition rate at very low-frequency range. Though this range of frequency has not been used by researchers, the results of this work indicate that it should not be ignored. Further investigation of the very low frequency range to identify emotional information is still in progress.


Subject(s)
Algorithms , Electromyography/methods , Emotions/classification , Emotions/physiology , Facial Expression , Facial Muscles/physiology , Pattern Recognition, Automated/methods , Adolescent , Adult , Aged , Artificial Intelligence , Biometry/methods , Child , Female , Humans , Male , Middle Aged , Psychometrics/methods , Reproducibility of Results , Sensitivity and Specificity , Young Adult
7.
Biomed Eng Online ; 12: 44, 2013 May 16.
Article in English | MEDLINE | ID: mdl-23680041

ABSTRACT

BACKGROUND: Identifying the emotional state is helpful in applications involving patients with autism and other intellectual disabilities; computer-based training, human computer interaction etc. Electrocardiogram (ECG) signals, being an activity of the autonomous nervous system (ANS), reflect the underlying true emotional state of a person. However, the performance of various methods developed so far lacks accuracy, and more robust methods need to be developed to identify the emotional pattern associated with ECG signals. METHODS: Emotional ECG data was obtained from sixty participants by inducing the six basic emotional states (happiness, sadness, fear, disgust, surprise and neutral) using audio-visual stimuli. The non-linear feature 'Hurst' was computed using Rescaled Range Statistics (RRS) and Finite Variance Scaling (FVS) methods. New Hurst features were proposed by combining the existing RRS and FVS methods with Higher Order Statistics (HOS). The features were then classified using four classifiers - Bayesian Classifier, Regression Tree, K- nearest neighbor and Fuzzy K-nearest neighbor. Seventy percent of the features were used for training and thirty percent for testing the algorithm. RESULTS: Analysis of Variance (ANOVA) conveyed that Hurst and the proposed features were statistically significant (p < 0.001). Hurst computed using RRS and FVS methods showed similar classification accuracy. The features obtained by combining FVS and HOS performed better with a maximum accuracy of 92.87% and 76.45% for classifying the six emotional states using random and subject independent validation respectively. CONCLUSIONS: The results indicate that the combination of non-linear analysis and HOS tend to capture the finer emotional changes that can be seen in healthy ECG data. This work can be further fine tuned to develop a real time system.


Subject(s)
Electrocardiography/methods , Emotions , Nonlinear Dynamics , Signal Processing, Computer-Assisted , Adolescent , Adult , Aged , Child , Female , Humans , Middle Aged , Statistics as Topic , Young Adult
8.
Sensors (Basel) ; 12(6): 7126-56, 2012.
Article in English | MEDLINE | ID: mdl-22969341

ABSTRACT

Magnetic Induction Tomography (MIT), which is also known as Electromagnetic Tomography (EMT) or Mutual Inductance Tomography, is among the imaging modalities of interest to many researchers around the world. This noninvasive modality applies an electromagnetic field and is sensitive to all three passive electromagnetic properties of a material that are conductivity, permittivity and permeability. MIT is categorized under the passive imaging family with an electrodeless technique through the use of excitation coils to induce an electromagnetic field in the material, which is then measured at the receiving side by sensors. The aim of this review is to discuss the challenges of the MIT technique and summarize the recent advancements in the transmitters and sensors, with a focus on applications in biological tissue imaging. It is hoped that this review will provide some valuable information on the MIT for those who have interest in this modality. The need of this knowledge may speed up the process of adopted of MIT as a medical imaging technology.


Subject(s)
Biosensing Techniques/instrumentation , Imaging, Three-Dimensional/instrumentation , Magnetics/instrumentation , Organ Specificity , Signal Processing, Computer-Assisted/instrumentation , Tomography/instrumentation , Humans
9.
J Med Syst ; 36(3): 1309-15, 2012 Jun.
Article in English | MEDLINE | ID: mdl-20844933

ABSTRACT

Acoustic analysis of infant cry signals has been proven to be an excellent tool in the area of automatic detection of pathological status of an infant. This paper investigates the application of parameter weighting for linear prediction cepstral coefficients (LPCCs) to provide the robust representation of infant cry signals. Three classes of infant cry signals were considered such as normal cry signals, cry signals from deaf babies and babies with asphyxia. A Probabilistic Neural Network (PNN) is suggested to classify the infant cry signals into normal and pathological cries. PNN is trained with different spread factor or smoothing parameter to obtain better classification accuracy. The experimental results demonstrate that the suggested features and classification algorithms give very promising classification accuracy of above 98% and it expounds that the suggested method can be used to help medical professionals for diagnosing pathological status of an infant from cry signals.


Subject(s)
Acoustics , Crying , Diagnostic Techniques and Procedures , Neural Networks, Computer , Probability , Humans , Infant, Newborn , Linear Models , Pattern Recognition, Automated/methods
10.
Comput Methods Programs Biomed ; 108(2): 559-69, 2012 Nov.
Article in English | MEDLINE | ID: mdl-21824676

ABSTRACT

Crying is the most noticeable behavior of infancy. Infant cry signals can be used to identify physical or psychological status of an infant. Recently, acoustic analysis of infant cry signal has shown promising results and it has been proven to be an excellent tool to investigate the pathological status of an infant. This paper proposes short-time Fourier transform (STFT) based time-frequency analysis of infant cry signals. Few statistical features are derived from the time-frequency plot of infant cry signals and used as features to quantify infant cry signals. General Regression Neural Network (GRNN) is employed as a classifier for discriminating infant cry signals. Two classes of infant cry signals are considered such as normal cry signals and pathological cry signals from deaf infants. To prove the reliability of the proposed features, two neural network models such as Multilayer Perceptron (MLP) and Time-Delay Neural Network (TDNN) trained by scaled conjugate gradient algorithm are also used as classifiers. The experimental results show that the GRNN classifier gives very promising classification accuracy compared to MLP and TDNN and the proposed method can effectively classify normal and pathological infant cries.


Subject(s)
Acoustics , Crying , Neural Networks, Computer , Databases, Factual , Humans , Infant , Spectroscopy, Fourier Transform Infrared
11.
J Med Syst ; 36(3): 1821-30, 2012 Jun.
Article in English | MEDLINE | ID: mdl-21249515

ABSTRACT

The goal of this paper is to discuss and compare three feature extraction methods: Linear Predictive Coefficients (LPC), Linear Prediction Cepstral Coefficients (LPCC) and Weighted Linear Prediction Cepstral Coefficients (WLPCC) for recognizing the stuttered events. Speech samples from the University College London Archive of Stuttered Speech (UCLASS) were used for our analysis. The stuttered events were identified through manual segmentation and were used for feature extraction. Two simple classifiers namely, k-nearest neighbour (kNN) and Linear Discriminant Analysis (LDA) were employed for speech dysfluencies classification. Conventional validation method was used for testing the reliability of the classifier results. The study on the effect of different frame length, percentage of overlapping, value of ã in a first order pre-emphasizer and different order p were discussed. The speech dysfluencies classification accuracy was found to be improved by applying statistical normalization before feature extraction. The experimental investigation elucidated LPC, LPCC and WLPCC features can be used for identifying the stuttered events and WLPCC features slightly outperforms LPCC features and LPC features.


Subject(s)
Diagnosis, Computer-Assisted , Speech-Language Pathology/classification , Humans , Models, Statistical
12.
Adv Exp Med Biol ; 696: 565-72, 2011.
Article in English | MEDLINE | ID: mdl-21431597

ABSTRACT

A brain machine interface (BMI) design for controlling the navigation of a power wheelchair is proposed. Real-time experiments with four able bodied subjects are carried out using the BMI-controlled wheelchair. The BMI is based on only two electrodes and operated by motor imagery of four states. A recurrent neural classifier is proposed for the classification of the four mental states. The real-time experiment results of four subjects are reported and problems emerging from asynchronous control are discussed.


Subject(s)
Man-Machine Systems , Wheelchairs , Brain/physiology , Computational Biology , Computer Systems , Electroencephalography , Equipment Design , Humans , Nervous System Diseases/rehabilitation , Neural Networks, Computer , User-Computer Interface