Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
J Orthop ; 15(2): 690-694, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29881222

ABSTRACT

One-hundred and three patients with intertrochanteric hip fractures as classified by the OTA 2007 system underwent fixation using the telescoping AOS Galileo lag screw system and ES Nail (a long IM nail). Thirty-one patients (76%) were female and ten (24%) were male, with an average age of 75.70 ±â€¯11.3 years at date of surgery. At final follow-up 21 (53%) patients returned to their pre-fracture ambulatory status, 20 (47%) had a reduction in ambulatory status, and no patients were confined to a wheel chair. The telescoping capability of the AOS Galileo lag screw allowed for a decrease in total length by 3.96 ±â€¯3.04 mm during fracture healing. The TAD distance at final follow-up was 14.09 ±â€¯4.69 mm. Lateral protrusion of the lag screw into soft tissue did not occur. There was one reported incidence of femoral head cutout, which occurred after the lag screw had telescoped its entire distance and began functioning as a rigid non-compressible lag screw. All other fractures healed uneventfully and no device failure occurred. The AOS Galileo telescoping lag screw has shown promise concerning IT fracture fixation and will continue to undergo further investigation.

2.
J Orthop Surg (Hong Kong) ; 23(2): 209-12, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26321553

ABSTRACT

PURPOSE: To validate our transfusion protocol based on pre- and post-operative complete blood count (CBC) data in patients undergoing primary total hip or knee arthroplasty (THA or TKA). METHODS: Records of 113 men and 205 women aged 32 to 94 (mean, 70) years who underwent primary uncemented THA (n=123) or cemented TKA (n=195) for osteoarthritis by 2 senior surgeons were reviewed. A post-surgical drain was used in 29 THA patients and 74 TKA patients, based on the surgeon's preference. CBC was assessed preoperatively, during postanaesthesia care, and at the beginning of postoperative days 1, 2, and 3 to determine their predictive power for transfusion rate. According to our transfusion protocol, blood was transfused when the haemoglobin (Hb) level was <80 g/l, or when hypotension, tachycardia, light-headedness, dizziness, or syncope occurred. RESULTS: Respectively in 123 and 195 patients who underwent THA and TKA, the transfusion rates within 3 days were 31.7% (n=39) and 25.6% (n=50). No patient required transfusion during postanaesthesia care; the transfusion rates of all patients during day 1 to day 2 and day 2 to day 3 were 15.1% (n=48) and 12.9% (n=41), respectively. The transfusion rate was higher in women than men (36.6% vs. 12.4%, p<0.001), but did not differ significantly in patients with or without a post-surgical drain (29.1% vs. 27.4%, p=0.754). Respectively for the Hb level of <130 g/l, 130-150 g/l, and >150 g/l, the overall transfusion rates were 48.5%, 22.0%, and 4.3% based on the preoperative level; 32.6%, 7.6%, and 0% based on the postanaesthesia care level; and 28.9%, 8.3%, and 0% based on the day 1 level. The predictive power of the preoperative Hb level was highest, followed by that during postanaesthesia care and the on day 1. CONCLUSION: CBC during postanaesthesia care is no more predictive than preoperative CBC. Preoperative optimisation and close monitoring of the Hb level from day 1 to day 3 is recommended.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Knee/methods , Blood Loss, Surgical/prevention & control , Blood Transfusion/methods , Postoperative Hemorrhage/prevention & control , Adult , Aged , Aged, 80 and over , Blood Cell Count , Female , Humans , Male , Middle Aged , Postoperative Hemorrhage/blood
3.
Am J Orthop (Belle Mead NJ) ; 44(5): E153-5, 2015 May.
Article in English | MEDLINE | ID: mdl-25950545

ABSTRACT

Various complications after intramedullary (IM) nailing of the tibia have been reported, the most common of which are anterior knee pain and symptoms similar to patella tendonitis. Complete rupture of the patellar tendon after IM nailing of the tibia has been reported on 2 occasions, in conjunction with predisposing patient factors, such as systemic disease or a proud tibial nail. Patellar tendon ruptures are disabling injuries that can be technically difficult to repair because of the poor quality of remaining tendon tissue, quadriceps muscle atrophy and/or contracture, and scar-tissue formation. Many methods have described the surgical reconstruction of the knee extensor mechanism, which is most commonly performed after total knee arthroplasty. We report the successful surgical and clinical outcome of patellar tendon reconstruction using an Achilles tendon allograft in a patient subject to late and recurrent ruptures after IM nailing of the tibia through a mid-patellar tendon-splitting approach. Seven months after tendon reconstruction, the patient exhibited full knee flexion, an extension lag of 10º, 4/5 quadriceps strength, and return to her baseline ambulatory status.


Subject(s)
Achilles Tendon/transplantation , Fracture Fixation, Intramedullary/adverse effects , Patellar Ligament/surgery , Tendon Injuries/surgery , Tibial Fractures/surgery , Adult , Allografts , Female , Humans , Patellar Ligament/injuries , Recovery of Function , Recurrence , Rupture , Tendon Injuries/etiology , Tibia/surgery , Treatment Outcome
4.
Injury ; 46(6): 963-9, 2015.
Article in English | MEDLINE | ID: mdl-25818058

ABSTRACT

OBJECTIVES: Short and long cephalomedullary (CM) nails are commonly used construct for fixation of intertrochanteric (IT) fractures. Each of these constructs has its advantages and its shortcomings. The extended-short (ES) CM nail offers a hybrid between long and short nail design that aims to combine their respective benefits. The goals of this study were to (1) biomechanically evaluate and compare construct stiffness for the long, short and ES constructs in the fixation of IT fractures, and to (2) investigate the nature of periprosthetic fractures of constructs implanted with these various designs. METHODS: Eighteen synthetic femora were used to evaluate three types of fracture fixation constructs. Axial compression, bending, and torsional stiffness were reported for both stable and comminuted IT fracture models. All comminuted fracture constructs were loaded to failure in axial compression to measure failure loads and evaluate periprosthetic fracture patterns. RESULTS: Stiffness were similar among constructs with few exceptions. Axial stiffness was significantly higher for the short nail compared to the long nail for the comminuted model (p= 0.020). ES nail constructs exhibited a significantly higher failure load than short nail constructs (p = 0.039). Periprosthetic fractures occurred around the distal interlocking screw in all constructs. CONCLUSIONS: Nail length and position of interlocking screw did not alter the biomechanical properties of the fixation construct in the presented IT fracture model. Periprosthetic fractures generated in this study had similar patterns to those seen clinically. This study also suggests that if a periprosthetic fracture is to occur, there is an increased probability of it happening around the site of the interlocking screw, regardless of nail design.


Subject(s)
Bone Nails , Femoral Fractures/surgery , Fracture Fixation, Intramedullary , Fractures, Comminuted/surgery , Hip Fractures/surgery , Biomechanical Phenomena , Fracture Fixation, Intramedullary/methods , Humans
5.
J Arthroplasty ; 27(7): 1413.e1-4, 2012 Aug.
Article in English | MEDLINE | ID: mdl-21978567

ABSTRACT

Total knee arthroplasty (TKA) continues to advance as innovative devices become available. #2 PDO Quill SRS (Angiotech, Reading, Pa) bidirectional barbed suture was used for 161 primary TKAs at our facility. We report on 3 separate cases of extensor mechanism repair failure after primary TKA in which a barbed suture was used for extensor mechanism closure. Before the implementation of this device, there were no reported failures in 385 primary TKAs. We recommend that surgeons who use this device for extensor mechanism repair of a medial parapatellar arthrotomy in TKA exercise caution when operating on patients with morbid obesity, diabetes, and rheumatoid arthritis. We have discontinued use of the bidirectional barbed suture until more definitive large orthopedic studies establish its efficacy and safety.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/surgery , Suture Techniques/adverse effects , Sutures/adverse effects , Aged , Anti-Bacterial Agents/therapeutic use , Equipment Failure , Female , Humans , Male , Middle Aged , Reoperation , Surgical Wound Infection/drug therapy , Treatment Failure , Wound Healing
6.
Orthopedics ; 34(12): e933-5, 2011 Dec 06.
Article in English | MEDLINE | ID: mdl-22146212

ABSTRACT

The authors report a case of nontraumatic, spontaneous dislocation of a polyethylene insert detected 1 year after total knee arthroplasty. The patient demonstrated initial improvement and returned to work 4 months postoperatively. At 6 months postoperatively, the patient developed pain and a clunking sensation with motion; however, he denied any traumatic precipitating events. An arthroscopic procedure revealed arthrofibrotic formations but no signs of locking mechanism failure. At 12 months postoperatively, the patient developed sudden instability, and radiographs demonstrated an anteriorly dislodged insert. Revision surgery was performed, and the insert was removed. The insert showed some signs of fatigue due to the locking mechanism. We postulated that repetitive flexion produced an anterior superior force leading to failure of the locking mechanism.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis , Polyethylene , Prosthesis Failure , Tibia/surgery , Aged , Female , Humans , Knee Joint/physiopathology , Knee Joint/surgery , Range of Motion, Articular , Reoperation
7.
Am J Orthop (Belle Mead NJ) ; 40(12): 630-5, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22268010

ABSTRACT

In light of recent health care reform and the aging US Medicare population, it is becoming increasingly important for orthopedic surgeons to use effective and efficient strategies for hip fracture surgery. The Extended-Short Nail System (ES nail) is a US Food and Drug Administration-approved titanium nail which is locked at the same location as the locking hole of a short intramedullary (IM) nail. The ES nail takes advantage of an "extended-short" hybrid design combining the mechanical characteristics of a long IM nail with the surgical ease of use offered with a short IM nail.


Subject(s)
Bone Nails , Femoral Neck Fractures/surgery , Fracture Fixation, Intramedullary/instrumentation , Activities of Daily Living , Adult , Aged , Aged, 80 and over , Female , Femoral Neck Fractures/diagnostic imaging , Femur/diagnostic imaging , Femur/surgery , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/methods , Humans , Male , Middle Aged , Postoperative Complications , Prosthesis Design , Radiography , Recovery of Function , Retrospective Studies , Titanium , Treatment Outcome
8.
Orthopedics ; 33(10): 767, 2010 Oct 11.
Article in English | MEDLINE | ID: mdl-20954652

ABSTRACT

Unilateral femoral neck stress fractures are well documented in active patients; however, the risk of a subsequent contralateral stress fracture remains unknown in patients who continue to be active. This article describes a 24-year-old male fire academy student who sustained a left femoral neck stress fracture, followed approximately 11 months later by a right femoral neck stress fracture, both of which went on to completely displace. A review of the index radiographs of each hip from outside institutions revealed femoral neck stress fractures that went undiagnosed until they displaced. The patient was referred to our institution and underwent closed reduction and internal fixation using cannulated screws in both cases. A full endocrine evaluation was performed in the following weeks and proved unremarkable. Although it is difficult to extrapolate the results from 1 patient beyond the case studied, there is cause for concern in patients who remain active following femoral neck stress fractures. Our case highlights the significance of obtaining a complete and thorough medical history on physical examination and appropriately counseling patients regarding activity level. Until further research explores this possible relationship, physicians evaluating patients with a history of a stress fracture are encouraged to be vigilant of subsequent contralateral fractures and educate patients of this potentially avoidable injury.


Subject(s)
Accidents, Occupational , Femoral Neck Fractures/pathology , Fractures, Stress/pathology , Workplace , Bone Screws , Femoral Neck Fractures/diagnostic imaging , Femoral Neck Fractures/surgery , Fires , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fractures, Stress/diagnostic imaging , Fractures, Stress/surgery , Hip Joint/physiopathology , Humans , Joint Dislocations/diagnostic imaging , Joint Dislocations/pathology , Joint Dislocations/surgery , Male , Pain/physiopathology , Radiography , Recovery of Function , Young Adult
9.
J Arthroplasty ; 25(1): 31-4, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19525089

ABSTRACT

Sciatic nerve palsy after revision hip arthroplasty is rare, but can have substantial impacts. The purpose of this study is to report the safety and reliability of limited sciatic nerve exposure during revision surgery. A retrospective case series of 350 revision hip surgeries performed by a single surgeon underwent sciatic nerve identification. In each case, the sciatic nerve was identified and tagged loosely with a Penrose drain. Three hundred forty-eight of 350 patients (99.4%) underwent successful revision hip arthroplasty. One patient developed a transient sensory palsy; and another patient, a delayed palsy. Both nerve palsies recovered by the 1-year visit. We advocate visual nerve identification and tagging in revision hip surgery as 1 possible method to potentially reduce the risks of sciatic nerve injury.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Sciatic Neuropathy/etiology , Adult , Aged , Arthroplasty, Replacement, Hip/methods , Female , Humans , Male , Middle Aged , Reoperation , Sciatic Nerve/anatomy & histology
10.
J Arthroplasty ; 22(3): 353-5, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17400090

ABSTRACT

Scar location and point loading of the scar after total knee arthroplasty are common postoperative concerns for patients and physicians. A frequent problem is discomfort associated with the incision. We evaluated 40 knees to better understand the association of the tibial tubercle with the overlying skin in both flexion and extension. Our results revealed lateral translation of the skin overlying the tibial tubercle in 100% of our volunteers as the knee is flexed and the tibia internally rotates. The average amount of lateral translation measured 9.7 mm. This could have a significant impact on point loading of the scar if an anterior midline incision for total knee arthroplasty is planned in extension.


Subject(s)
Arthroplasty, Replacement, Knee , Cicatrix/physiopathology , Knee Joint/physiopathology , Skin/physiopathology , Adult , Arthroplasty, Replacement, Knee/methods , Female , Humans , Male , Middle Aged , Rotation , Stress, Mechanical , Tibia/physiopathology
11.
J Orthop Trauma ; 20(5): 303-9; discussion 315-6, 2006 May.
Article in English | MEDLINE | ID: mdl-16766931

ABSTRACT

OBJECTIVE: To evaluate and present our experience using the expandable nail system for the treatment of acute tibial shaft fractures. DESIGN: Retrospective study. SETTING: Two level-1 trauma centers-University teaching hospitals. METHODS: Fifty-four consecutive patients were treated by this nail system for acute tibial shaft fracture. Two nail diameters were used, 8.5 mm and 10 mm. Operation, hospitalization and healing times, reaming versus nonreaming, isolated versus multiple injuries, and reoperations were recorded and analyzed statistically. RESULTS: Follow-up was obtained either until fracture healing or for a minimum of 1 year with an average of 14 months (12 to 24). All fractures healed in an average time of 72 days (21 to 204). The average healing times for patients treated with 8.5-mm and 10-mm nails were 77.2 days (27 to 204) and 63.4 days (21 to 121), respectively. Average operative time was 103 minutes (40 to 185) if reamed and 56 minutes (30 to 80) if unreamed. Average healing times were 65.4 days (21 to 190) if reamed and 79.5 days (42 to 204) if unreamed. There were 11 complications (20.4%) related to the nailing: 3 deep infections, 2 superficial infections, 2 bone shortenings of 1 cm secondary to nail protrusion in the knee, 1 compartment syndrome, 1 fracture propagation, 1 distal malalignment, and 1 delayed union. Hardware was removed in 6 patients (3 infections, 2 patients' request and 1 protrusion into the knee), and 1 additional patient underwent exchange nailing due to a delayed union. CONCLUSIONS: The expandable nail offers the theoretical advantages of improved load sharing and rotational control without the need for interlocking screws. This study demonstrates satisfactory healing and alignment for the treatment of tibial shaft fractures using this device. However, caution must be exercised when using this nail in cases of significant comminution and in cases where the fracture pattern involves the more proximal or distal aspect of the tibial shaft.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary/instrumentation , Tibial Fractures/surgery , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Postoperative Complications/diagnostic imaging , Radiography , Retrospective Studies , Tibial Fractures/diagnostic imaging , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...