1.
J Cancer Res Ther ; 18(6): 1504-1512, 2022.
Article in English | MEDLINE | ID: mdl-36412401

ABSTRACT

Introduction: The number of patients for carcinoma cervix with implanted hip prostheses has been increasing worldwide during the past several decades. Technological advancements are useful for delivering higher doses, i.e., dose escalation to the target, but the presence of high-density implanted hip prosthesis creates challenges for the planner. Materials and Methods: A population of 25 patients was selected for the study. Plans were generated using the MONACO treatment planning system keeping the isocenter same. The parameters evaluated for planning target volume (PTV) were D98%, D50%, D2%, Dmax, Dmean, V107%, and V110%. Similarly, the parameters Dmax, Dmean, and D2cc were evaluated for the delineated critical organs. Average monitor units (TMUmean) were also assessed. Results: D98% of PTV was 44.51 (standard deviation [SD]: 0.13) Gy, 44.41 (SD: 0.38) Gy, 44.58 (SD: 0.14) Gy, 44.08 (SD: 0.41) Gy and 44.46 (SD: 0.32) Gy for 4F, intensity-modulated radiation therapy (IMRT), IMRT_WP, volumetric-modulated arc therapy (VMAT), and VMAT_WP techniques, respectively, where WP stands for "without prosthesis". Volume of bowel receiving 45 Gy was 86.82 (SD: 66.38) cm3, 6.97 (SD: 5.77) cm3, 14.11 (SD: 14.29) cm3, 13.31 (SD: 6.57) cm3, and 10.31 (SD: 10.94) cm3 for 4F, IMRT, IMRT_WP, VMAT and VMAT_WP techniques, respectively. Discussion: Radiotherapy is standard care of practice for known cases of cervical malignancies. As per our investigations, VMAT has generated comparable plans in terms of target coverage (D98%) as compared to IMRT and 4F techniques (P = 0.015 and P = 0.002) and with prosthesis also (P = 0.024). The mean dose to the bladder was significantly lesser with IMRT and VMAT. Our results highlight that VMAT has reduced the mean dose to the rectum (P = 0.001) in presence of high-density implant. The mean dose to femoral heads was also reduced when compared with the 4-field technique. Conclusion: VMAT has an edge over other techniques in terms of target coverage and sparing of critical organs in the presence of metallic prosthesis. Information about the geometry and density of prosthesis will be beneficial for treatment planning.


Subject(s)
Carcinoma , Radiotherapy, Intensity-Modulated , Uterine Cervical Neoplasms , Female , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Uterine Cervical Neoplasms/radiotherapy , Cervix Uteri , Prostheses and Implants
2.
J Cancer Res Ther ; 17(6): 1491-1498, 2021.
Article in English | MEDLINE | ID: mdl-34916383

ABSTRACT

AIM: To validate the Acuros® XB (AXB) algorithm in Eclipse treatment planning system (TPS) for RapidArc™ (RA) technique following the software upgrades. MATERIALS AND METHODS: A Clinac-iX (2300CD) linear accelerator and Eclipse TPS (Varian Medical System, Inc., Palo Alto, USA) was used for commissioning of AXB algorithm using a 6 megavolts photon beam. Percentage depth dose (PDD) and profiles for field size 2 cm × 2 cm, 4 cm × 4 cm, 6 cm × 6 cm, 10 cm × 10 cm, 20 cm × 20 cm, 30 cm × 30 cm to 40 cm × 40 cm were taken. AXB calculated PDDs and profiles were evaluated against the measured and analytical anisotropic algorithm (AAA)-calculated PDDs and profiles. Test sites recommended by American Association of Physicists in Medicine task group (AAPM TG)-119 recommendation were used for RA planning and delivery verification using AXB algorithm.Dosimetric analysis of AXB calculated data showed that difference between calculated and measured data for PDD curves were maximum <1% beyond the depth of dose maximum and computed profiles in central region matches with maximum <1% for all considered field sizes. Ion-chamber measurements showed that the average confidence limit (CLs) was 0.034 and 0.020 in high-gradient and 0.047 and 0.042 in low-gradient regions, respectively, for AAA and AXB calculated RA plans. Portal measurements show the average CLs were 2.48 and 2.58 for AAA and AXB-calculated RA plans, with gamma passing criteria of 3%/3 mm. CONCLUSIONS: AXB shows excellent agreement with measurements and AAA calculated data. The CLs were consistent with the baseline values published by TG-119. AXB algorithm has the potential to perform photon dose calculation with comparable fast calculation speed without negotiating the accuracy. AAPM TG-119 was successfully implemented to access the proper configuration of AXB algorithm following the TPS upgrade.


Subject(s)
Neoplasms/radiotherapy , Photons/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Anisotropy , Humans , Radiometry/methods , Software
3.
Rep Pract Oncol Radiother ; 26(5): 688-711, 2021.
Article in English | MEDLINE | ID: mdl-34760305

ABSTRACT

BACKGROUND: Routinely, patient's planning scans are acquired after administration of iodinized contrast media but they will be treated in the absence of that. Similarly, high energy photons have a better penetrating power, while low energy photons will result in tighter dose distribution and negligible neutron contamination. The aim of the study was to investigate a suitable photon beam energy in the presence of intravenous contrast medium. MATERIALS AND METHODS: An indigenously made original-contrast (OC) phantom was mentioned as virtual-contrast (VC) and virtual-without-contrast (VWC) phantom were generated by assigning the Hounsfield Units (HU) to different structures. Intensity-modulated (IMRT) and volumetric-modulated-arc (VMAT) plans were generated as per criteria of the TG-119 protocol. RESULTS: It was observed that the maximum dose to the spinal cord was better with 6 mega-voltage (MV) in IMRT. The coverage of Prostate PTV (PR PTV) was similar with all the photon energies and was comparable with TG-119, except for original-contrast (OC) phantom using the VMAT technique. Homogeneity-index (HI) was comparatively better for VMAT plans. CONCLUSION: The contrast CT images lower the dose to targets. IMRT or VMAT plans, generated on such CT images will be delivered with higher doses than evaluated. However, the overdose remains non-significant.

4.
J Egypt Natl Canc Inst ; 33(1): 2, 2021 Jan 07.
Article in English | MEDLINE | ID: mdl-33415487

ABSTRACT

BACKGROUND: The number of people with implanted hip prosthesis has grown worldwide. For radiotherapy planning of patients with hip implants, few main challenges are encountered. The aim of the present study was to evaluate the feasibility of different planning algorithms in the presence of high-density metallic implant in the treatment of patients with carcinoma cervix. RESULTS: It was found that D98% were 44.49 ± 0.11, 44.51 ± 0.13, 44.39 ± 0.22, and 44.45 ± 0.16 Gy for 4FMC6MV (4-field technique calculated with Monte-Carlo algorithm and 6 MV photon energy), 4FMC6MV_WP (4-field technique calculated with Monte-Carlo algorithm and 6 MV photon energy without prosthesis), 4FCC6MV (4-field technique calculated with collapse-cone-convolution algorithm and 6 MV photon energy), and 4FCC6MV_WP (4-field technique calculated with collapse-cone-convolution algorithm and 6 MV photon energy without prosthesis) respectively. Similarly, D2% were 49.40 ± 0.84, 49.05 ± 0.76, 48.97 ± 0.91, and 48.57 ± 0.85 Gray (Gy) for 4FMC6MV, 4FMC6MV_WP, 4FCC6MV, and 4FCC6MV_WP respectively. The present study has not suggested any major difference between the Monte-Carlo (MC) and collapse-cone-convolution (CCC) calculation algorithm in the presence of high-Z metallic implants. Volume of bowel receiving 15 Gy dose has shown a significant difference with prosthesis cases. This study investigates that hip prosthesis creates considerable changes in the treatment planning of cervical malignancies. CONCLUSION: CCC algorithm is in good agreement with MC calculation algorithm in the presence of high-density metallic implants in terms of target coverage and avoidance organ sparing except few parameters.


Subject(s)
Algorithms , Radiotherapy Planning, Computer-Assisted , Feasibility Studies , Humans , Prostheses and Implants , Radiotherapy Dosage
5.
Asian Pac J Cancer Prev ; 21(6): 1731-1738, 2020 Jun 01.
Article in English | MEDLINE | ID: mdl-32592371

ABSTRACT

INTRODUCTION: Aim of study is to investigate the effect of hip prosthesis on 6 and 15 MV photon beam energies. MATERIALS AND METHODS: Prosthesis was kept at the level of tray position. The measurements were done on Varian Clinac-iX linac. Customized prosthesis, termed as Prosthetic Metal Implant (PMI) was made up of wrought austenitic stainless steel rod and covered with paraffin-wax. 'Standard prosthesis' was made up of wrought titanium alloy. The dose profiles were measured for three field sizes i.e. 5, 10 and 20 cm at 100 cm SSD for 6 and 15 MV energies. The perturbation index (PI) was also calculated. RESULTS: Perturbation caused by standard prosthesis was approximately 50% higher than that of PMI. This result may be due to difference in dimension and not because of material composition. Variation of central axis dose might be due to the dimensions of PMI used for experiment which gave intermediate response (e.g. 102.1%, 141.0% and 117.7% for Open, Standard and PMI respectively for 10x10 cm2 field size, 10 cm depth and 15MV photon beam setup )as compared to the 'open' and 'standard' prosthesis. Percentage dose at 10 cm for 6MV photon increased rapidly with field-size for PMI. But, for 15MV photon, difference was not significant. Surface dose (Ds) for PMI remains significantly higher for smaller field. CONCLUSION: The perturbation index varied from 0.05 to 0.22 for the measured energies and gave an idea to the planner to assess the behavior of the prosthesis. This range is applicable for both type of implants and for all clinical field-sizes. The attenuation caused by the prosthesis was significant and this effect should be considered in the treatment planning calculations.


Subject(s)
Computer Simulation , Hip Prosthesis , Particle Accelerators/instrumentation , Phantoms, Imaging , Photons , Radiotherapy Planning, Computer-Assisted/methods , Humans , Monte Carlo Method , Radiotherapy Dosage , Titanium/chemistry
6.
Rep Pract Oncol Radiother ; 25(4): 507-514, 2020.
Article in English | MEDLINE | ID: mdl-32494224

ABSTRACT

AIM: To investigate the impact of Acuros XB (AXB) algorithm in the deep-inspiration breath-hold (DIBH) technique used for treatment of left sided breast cancer. BACKGROUND: AXB may estimate better lung toxicities and treatment outcome in DIBH. MATERIALS AND METHODS: Treatment plans were computed using the field-in-field technique for a 6 MV beam in two respiratory phases - free breathing (FB) and DIBH. The AXB-calculations were performed under identical beam setup and the same numbers of monitor units as used for AAA-calculation. RESULTS: Mean Hounsfield units (HU), mass density (g/cc) and relative electron density were -782.1 ±â€¯24.8 and -883.5 ±â€¯24.9; 0.196 ±â€¯0.025 and 0.083 ±â€¯0.032; 0.218 ±â€¯0.025 and 0.117 ±â€¯0.025 for the lung in the FB and DIBH respiratory phase, respectively. For a similar target coverage (p > 0.05) in the DIBH respiratory phase between the AXB and AAA algorithm, there was a slight increase in organ at risk (OAR) dose for AXB in comparison to AAA, except for mean dose to the ipsilateral lung. AAA predicts higher mean dose to the ipsilateral lung and lesser V20Gy for the ipsilateral and common lung in comparison to AXB. The differences in mean dose to the ipsilateral lung were 0.87 ±â€¯2.66 % (p > 0.05) in FB, and 1.01 ± 1.07% (p < 0.05) in DIBH, in V20Gy the differences were 1.76 ±â€¯0.83% and 1.71 ±â€¯0.82% in FB (p < 0.05), 3.34 ± 1.15 % and 3.24 ± 1.17 % in DIBH (p < 0.05), for the ipsilateral and common lung, respectively. CONCLUSION: For a similar target volume coverage, there were important differences between the AXB and AAA algorithm for low-density inhomogeneity medium present in the DIBH respiratory phase for left sided breast cancer patients. DIBH treatment in conjunction with AXB may result in better estimation of lung toxicities and treatment outcome.

7.
J Med Phys ; 44(2): 126-134, 2019.
Article in English | MEDLINE | ID: mdl-31359931

ABSTRACT

AIM: This study validated the RapidArc (RA) delivery using a volumetric ArcCHECK phantom as per the guidelines proposed in Task Group Report 119 from the American Association of Physicists in Medicine Task group 119 (AAPM TG 119). This study also investigated the impact of the Acuros XB (AXB) algorithm in comparison to analytical anisotropic algorithm (AAA) on the RA dose calculations in the homogeneous medium of the ArcCHECK phantom. MATERIALS AND METHODS: A volumetric ArcCHECK phantom along with AAPM TG 119 tests was used to evaluate the RA plans and verify the dose delivery for photon beam of 6 MV energy. RESULTS: The RA planning results were comparable and satisfied the planning criteria stated in the TG 119 report for all test cases. The average percentage gamma passing rates for the AAA-calculated plans were 98.5 (standard deviation [SD]: 0.6), 98.5 (SD: 1.3), and 98.1 (SD: 2.0) and for the AXB-calculated plans were 95.1 (SD: 1.8), 96.1 (SD: 1.3), and 94.0 (SD: 0.9) for the Clinac-iX (6 MV) and TrueBeam (TB)-STx (6 MV_filtered beam [FB] and 6 MV_flattening filter-free beam [FFFB]), respectively. For ion chamber measurements, the average percentage dose differences for the AAA-calculated plans were 1.5 (SD: 2.5), 2.7 (SD: 1.4), and 1.4(SD: 2.7) and for AXB-calculated plans were 2.3 (SD: 1.6), 3.2 (SD: 1.5), and 2.3 (SD: 2.0) for Clinac-iX (6 MV) and TB-STx (6 MV_FB and 6 MV_FFFB), respectively. CONCLUSION: Thus, the ArcCHECK can successfully be utilized for the validation of the RA delivery. The AXB has potential to perform dose calculations comparable to those of the AAA for RA plans in the homogeneous medium of the ArcCHECK phantom.

8.
J Gastrointest Cancer ; 50(3): 408-419, 2019 Sep.
Article in English | MEDLINE | ID: mdl-29520733

ABSTRACT

PURPOSE: To evaluate the feasibility of flattening filter free beam (FFFB) for the treatment of gastric tumors and to review their benefits over 6MV flatten beam (6MV_FFB). METHODS: Fifteen patients with histologically proven gastric carcinoma were selected. CT scans with slice thickness of 0.3 cm were acquired and planning target volume (PTV) and organ at risk (OAR) were delineated. Plans were made retrospectively for each patient for the prescription dose of 45 Gy/25 fractions to the PTV. Four isocentric plans were compared in the present study on Varian TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, CA, USA). RESULTS: PTV D98% was 44.41 ± 0.12, 44.38 ± 0.13, 44.59 ± 0.14, and 44.49 ± 0.19 Gy for IMRT 6MV_FFB, IMRT 6MV_FFFB, VMAT 6MV_FFB, and VMAT 6MV_FFFB respectively. 6MV_FFFB beam minimizes the mean heart dose Dmean (P = 0.001). VMAT dominates over IMRT when it came to kidney doses V12Gy (P = 0.02), V23Gy (P = 0.015), V28Gy (P = 0.011), and Dmax (P < 0.01). VMAT has significantly reduced the doses to kidneys. It was analyzed that 6MV_FFFB significantly reduces the dose to normal tissues (P = 0.006 and P = 0.018). VMAT significantly reduces the TMU, which is required to deliver the similar dose by IMRT (P < 0.01). CONCLUSIONS: Unflattened beam spares the organs at risk significantly to avoid the chances of secondary malignancies and reduces the intra-fraction motion during treatment due to provision of higher dose rate. Hence, we conclude that 6MV unflattened beam can be used to treat gastric carcinoma.


Subject(s)
Organs at Risk/radiation effects , Quality Assurance, Health Care/standards , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy, Intensity-Modulated/methods , Stomach Neoplasms/radiotherapy , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Cross-Sectional Studies , Feasibility Studies , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Prognosis , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/classification , Retrospective Studies , Young Adult
9.
Int J Part Ther ; 4(2): 1-10, 2017.
Article in English | MEDLINE | ID: mdl-31773003

ABSTRACT

PURPOSE: Brachytherapy is essential for local treatment in cervical carcinoma, but some patients are not suitable for it. Presently, for these patients, the authors prefer a boost by using intensity-modulated radiation therapy (IMRT). The authors evaluated the dosimetric comparison of proton-modulated radiation therapy versus IMRT and volumetric-modulated arc therapy (VMAT) as a boost to know whether protons can replace photons. PATIENTS AND METHODS: Five patients who received external beam radiation therapy to the pelvis by IMRT were reviewed. Three different plans were made, including pencil beam scanning (PBS), IMRT, and VMAT. The prescribed planning target volume (PTV) was 20 Gy in 4 fractions. The dose to 95% PTV (D95%), the conformity index, and the homogeneity index were evaluated for PTV. The Dmax, D2cc, and Dmean were evaluated for organs at risk along with the integral dose of normal tissue and organs at risk. RESULTS: The PTV coverage was optimal and homogeneous with modulated protons and photons. For PBS, coverage D95% was 20.01 ± 0.02 Gy (IMRT, 20.08 ± 0.06 Gy; VMAT, 20.1 ± 0.04 Gy). For the organs at risk, Dmax of the bladder for PBS was 21.05 ± 0.05 Gy (IMRT, 20.8 ± 0.21 Gy; VMAT, 21.65 ± 0.41 Gy) while the Dmax for the rectum for PBS was 21.04 ± 0.03 Gy (IMRT, 20.81 ± 0.12 Gy; VMAT, 21.66 ± 0.38 Gy). Integral dose to normal tissues in PBS was 14.17 ± 2.65 Gy (IMRT, 25.29 ± 6.35 Gy; VMAT, 25.24 ± 6.24 Gy). CONCLUSIONS: Compared with photons, modulated protons provide comparable conformal plans. However, PBS reduces the integral dose to critical structures significantly compared with IMRT and VMAT. Although PBS may be a better alternative for such cases, further research is required to substantiate such findings.

10.
Rep Pract Oncol Radiother ; 22(1): 1-9, 2017.
Article in English | MEDLINE | ID: mdl-27790072

ABSTRACT

AIM: Aim of the present study was to compare the dosimetric impact of different photon beam energies and number of arcs in the treatment of carcinoma cervix. BACKGROUND: Carcinoma cervix is a common cancer in women worldwide with a high morbidity rate. Radiotherapy is used to treat such tumours. Volumetric Modulated Arc Therapy (VMAT) is considered superior to other techniques with multiple arcs and energies. MATERIALS AND METHODS: Twenty patients with carcinoma cervix underwent radiotherapy in a prospective observation study conducted at our institute. Volumetric modulated arc plans with 6 MV, 10 MV and 15 MV photon energies using single arc (SA) and dual arc (DA) were generated. Several physical indices for planning target volume (PTV) like V95%, V100%, V110%, D98%, D50%, D2% and total number of MUs were compared. Normal Tissue Integral Dose (NTID) and dose to a shell structure PHY2.5 and PHY5.0 were analyzed. RESULTS: Comparable dose coverage to PTV was observed for all the energies and arcs. CI for DA6MV (1.095) was better than SA6MV (1.127), SA10MV (1.116) and SA15MV (1.116). Evaluated parameters showed significant reduction in OAR doses. Mean bladder dose for DA6MV (41.90 Gy) was better than SA6MV (42.48 Gy), SA10MV (42.08 Gy) and SA15MV (41.93 Gy). Similarly, p-value for the mean rectal dose calculated was 0.001 (SA6 vs 15), 0.013 (DA6 vs 10) and 0.003 (DA6 vs 15) and subsequently favoured DA6MV. Difference in NTID was very small. CONCLUSIONS: The study showed no greater advantage of higher energy, and DA VMAT plan with 6 MV photon energy was a good choice of treatment for carcinoma cervix as it delivered a highly homogeneous and conformal plan with superior target coverage and better OAR sparing.

11.
Rep Pract Oncol Radiother ; 22(1): 10-18, 2017.
Article in English | MEDLINE | ID: mdl-27790073

ABSTRACT

AIM: To investigate the dosimetric influence of filtered and flattening filter free (FFF) photon beam of 6 and 10 MV energies on cervix RA radiotherapy planning and to find possibilities to develop the clinically acceptable RA plans with FFFB photon beam and explore their potential benefits to cervix cancer patients. BACKGROUND: FFF photon beams enhances the treatment delivery by increased dose rate which results in shorter treatment time, this shorter treatment time reduces intrafraction motion and enhance comfort to the patients. MATERIALS AND METHODS: RA plans were generated for filtered and flattening filter free photon beams of 6 and 10 MV energies using same dose-volumes constraints. RA plans were generated to deliver a dose of 50.4 Gy in 28 fractions, for a cohort of eleven patients reported with cervix carcinoma. RA plans were evaluated in terms of PTV coverage, dose to OAR's, CI, HI, total no. of monitor units (MUs) and NTID and low dose volume of normal tissues. RESULTS: Clinically acceptable and similar plans were generated for filtered and flattening filter free photon beams. FFFB delivered slightly higher mean target dose (52.28 Gy vs. 52.0 Gy, p = 0.000 for 6 MV and 52.42 Gy vs. 52.0 Gy, p = 0.000 for 10 MV) less homogeneous (1.062 vs. 1.052, p = 0.000 for 6 MV and 1.066 vs. 1.051, p = 0.000 for 10 MV) and less conformal (1.007 vs. 1.004, p = 0.104 for 6 MV and 1.012 vs. 1.003, p = 0.010 for 10 MV) RA plans compared to FB. FFFB delivered more doses to the bladder and rectum, also required more numbers of MUs in comparison to FB. CONCLUSIONS: This study concludes that FB is more beneficial for cervix RA planning in comparison to FFFB, as FB generates more conformal and homogenous rapid arc plans and offers better OAR's sparing.

12.
Asian Pac J Cancer Prev ; 17(11): 4935-4937, 2016 11 01.
Article in English | MEDLINE | ID: mdl-28032499

ABSTRACT

Objective: To compare dosimetric parameters of 3 dimensional conformal radiotherapy (3 DCRT) and intensity modulated radiotherapy (IMRT) in terms of target coverage and doses to organs at risk (OAR) in the management of rectal carcinoma. Methods: In this prospective study, conducted between August 2014 and March 2016, all patients underwent CT simulation along with a bladder protocol and target contouring according to the Radiation Therapy Oncology Group (RTOG) guidelines. Two plans were made for each patient (3 DCRT and IMRT) for comparison of target coverage and OAR. Result: A total of 43 patients were recruited into this study. While there were no significant differences in mean Planning Target Volume (PTV) D95% and mean PTV D98% between 3 DCRT and IMRT, mean PTV D2% and mean PTV D50% were significantly higher in 3 DCRT plans. Compared to IMRT, 3 DCRT resulted in significantly higher volumes of hot spots, lower volumes of cold spots, and higher doses to the entire OAR. Conclusion: This study demonstrated that IMRT achieves superior normal tissue avoidance (bladder and bowel) compared to 3 DCRT, with comparable target dose coverage.

13.
J Med Phys ; 41(2): 85-91, 2016.
Article in English | MEDLINE | ID: mdl-27217619

ABSTRACT

The purpose of this study was to evaluate the central axis dose in the build-up region and the surface dose of a 6 MV and 10 MV flattened photon beam (FB) and flattening filter free (FFF) therapeutic photon beam for different square field sizes (FSs) for a Varian Truebeam linear accelerator using parallel-plate ionization chamber and Gafchromic film. Knowledge of dosimetric characteristics in the build-up region and surface dose of the FFF is essential for clinical care. The dose measurements were also obtained empirically using two different commonly used dosimeters: a p-type photon semiconductor dosimeter and a cylindrical ionization chamber. Surface dose increased linearly with FS for both FB and FFF photon beams. The surface dose values of FFF were higher than the FB FSs. The measured surface dose clearly increases with increasing FS. The FFF beams have a modestly higher surface dose in the build-up region than the FB. The dependence of source to skin distance (SSD) is less significant in FFF beams when compared to the flattened beams at extended SSDs.

14.
J Med Phys ; 41(1): 65-70, 2016.
Article in English | MEDLINE | ID: mdl-27051173

ABSTRACT

Organ motions during inter-fraction and intra-fraction radiotherapy introduce errors in dose delivery, irradiating excess of normal tissue, and missing target volume. Lung and heart involuntary motions cause above inaccuracies and gated dose delivery try to overcome above effects. Present work attempts a novel method to verify dynamic dose delivery using a four-dimensional (4D) phantom. Three patients with mobile target are coached to maintain regular and reproducible breathing pattern. Appropriate intensity projection image set generated from 4D-computed tomography (4D-CT) is used for target delineation. Intensity modulated radiotherapy plans were generated on selected phase using CT simulator (Siemens AG, Germany) in conjunction with "Real-time position management" (Varian, USA) to acquire 4D-CT images. Verification plans were generated for both ion chamber and Gafchromic (EBT) film image sets. Gated verification plans were delivered on the phantom moving with patient respiratory pattern. We developed a MATLAB-based software to generate maximum intensity projection, minimum intensity projections, and average intensity projections, also a program to convert patient breathing pattern to phantom compatible format. Dynamic thorax quality assurance (QA) phantom (Computerized Imaging Reference Systems type) is used to perform the patient specific QA, which holds an ion chamber and film to measure delivered radiation intensity. Exposed EBT films are analyzed and compared with treatment planning system calculated dose. The ion chamber measured dose shows good agreement with planned dose within ± 0.5% (0.203 ± 0.57%). Gamma value evaluated from EBT film shows passing rates 92-99% (96.63 ± 3.84%) for 3% dose and 3 mm distance criteria. Respiratory gated treatment delivery accuracy is found to be within clinically acceptable level.

15.
Rep Pract Oncol Radiother ; 21(1): 50-6, 2016.
Article in English | MEDLINE | ID: mdl-26900358

ABSTRACT

AIM: The aim of this study is to evaluate performance of ArcCHECK diode array detector for the volumetric modulated arc therapy (VMAT) patient specific quality assurance (QA). VMAT patient specific QA results were correlated with ion chamber measurement. Dose response of the ArcCHECK detector was studied. BACKGROUND: VMAT delivery technique improves the dose distribution. It is complex in nature and requires proper QA before its clinical implementation. ArcCHECK is a novel three dimensional dosimetry system. MATERIALS AND METHODS: Twelve retrospective VMAT plans were calculated on ArcCHECK phantom. Point dose and dose map were measured simultaneously with ion chamber (IC-15) and ArcCHECK diode array detector, respectively. These measurements were compared with their respective TPS calculated values. RESULTS: The ion chamber measurements are in good agreement with TPS calculated doses. Mean difference between them is 0.50% with standard deviation of 0.51%. Concordance correlation coefficient (CCC) obtained for ion chamber measurements is 0.9996. These results demonstrate a strong correlation between the absolute dose predicted by our TPS and the measured dose. The CCC between ArcCHECK doses and TPS predictions on the CAX was found to be 0.9978. In gamma analysis of dose map, the mean passing rate was 98.53% for 3% dose difference and 3 mm distance to agreement. CONCLUSIONS: The VMAT patient specific QA with an ion chamber and ArcCHECK phantom are consistent with the TPS calculated dose. Statistically good agreement was observed between ArcCHECK measured and TPS calculated. Hence, it can be used for routine VMAT QA.

16.
Rep Pract Oncol Radiother ; 20(3): 170-80, 2015.
Article in English | MEDLINE | ID: mdl-25949220

ABSTRACT

AIM: To measure and compare the head scatter factor for 7 MV unflattened and 6 MV flattened photon beam using a home-made designed mini phantom. BACKGROUND: The head scatter factor (Sc) is one of the important parameters for MU calculation. There are multiple factors that influence the Sc values, like accelerator head, flattening filter, primary and secondary collimators. MATERIALS AND METHODS: A columnar mini phantom was designed as recommended by AAPM Task Group 74 with high and low atomic number material for measurement of head scatter factors at 10 cm and d max dose water equivalent thickness. RESULTS: The Sc values measured with high-Z are higher than the low-Z mini phantoms observed for both 6MV-FB and 7MV-UFB photon energies. Sc values of 7MV-UFB photon beams were smaller than those of the 6MV-FB photon beams (0.6-2.2% (Primus), 0.2-1.4% (Artiste) and 0.6-3.7% (Clinac iX (2300CD))) for field sizes ranging from 10 cm × 10 cm to 40 cm × 40 cm. The SSD had no influence on head scatter for both flattened and unflattened beams. The presence of wedge filters influences the Sc values. The collimator exchange effects showed that the opening of the upper jaw increases Sc irrespective of FF and FFF. CONCLUSIONS: There were significant differences in Sc values measured for 6MV-FB and unflattened 7MV-UFB photon beams over the range of field sizes from 10 cm × 10 cm to 40 cm × 04 cm. Different results were obtained for measurements performed with low-Z and high-Z mini phantoms.

17.
J Med Phys ; 40(4): 207-13, 2015.
Article in English | MEDLINE | ID: mdl-26865756

ABSTRACT

The main purpose of this study is to know the effect of three different photon energies viz., 6, 10, and 15 mega voltage (MV) on RapidArc (RA) planning for deep-seated cervix tumor and to develop clinically acceptable RA plans with suitable photon energy. RA plans were generated for 6, 10, and 15 MV photon energies for twenty patients reported with cervix carcinoma. RA plans were evaluated in terms of planning target volume (PTV) coverage, dose to organs at risk (OARs), conformity index (CI), homogeneity index (HI), gradient measure, external volume index of dose distribution produced, total number of monitor units (MUs), nontumor integral dose (ID), and low dose volume of normal tissue. A two-sample paired t-test was performed to compare the dosimetric parameters of RA plans. Irrespective of photon energy used for RA planning, plans were dosimetrically similar in terms of PTV coverage, OARs sparing, CI and HI. The numbers of MUs were 13.4 ± 1.4% and 18.2 ± 1.5% higher and IDs were 2.7 ± 0.8% and 3.7 ± 0.9% higher in 6 MV plans in comparison to that in the 10 and 15 MV plans, respectively. V1Gy, V2Gy, V3Gy, and V4Gy were higher in 6 MV plans in comparison to that in 10 and 15 MV plans. Based on this study, 6 MV photon beam is a good choice for RA planning in case of cervix carcinoma, as it does not deliver additional exposure to patients caused by photoneutrons produced in high energy beams.

18.
J Med Phys ; 39(3): 184-91, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25190997

ABSTRACT

To measure and compare the head scatter factor for flattened (FB) and unflattened (FFF) of 6MV and 10MV photon beam using indigenously designed mini phantom. A columnar mini phantom was designed as recommended by AAPM Task Group 74 with low and high atomic number materials at 10 cm (mini phantom) and at approximately twice the depth of maximum dose water equivalent thickness (brass build-up cap). Scatter in the accelerator (Sc) values of 6MV-FFF photon beams are lesser than that of the 6MV-FB photon beams (0.66-2.8%; Clinac iX, 2300CD) and (0.47-1.74%; True beam) for field sizes ranging from 10 × 10 cm(2) to 40 × 40 cm(2). Sc values of 10MV-FFF photon beams are lesser (0.61-2.19%; True beam) than that of the 10MV-FB photons beams for field sizes ranging from 10 × 10 cm(2) to 40 × 40 cm(2). The SSD had no influence on head scatter for both flattened and unflattened beams and irrespective of head design of the different linear accelerators. The presence of field shaping device influences the Sc values. The collimator exchange effect reveals that the opening of the upper jaw increases Sc irrespective of FB or FFF photon beams and different linear accelerators, and it is less significant in FFF beams. Sc values of 6MV-FB square field were in good agreement with that of AAPM, TG-74 published data for Varian (Clinac iX, 2300CD) accelerator. Our results confirm that the removal of flattening filter decreases in the head scatter factor compared to flattened beam. This could reduce the out-of-field dose in advanced treatment delivery techniques.

19.
Med Phys ; 39(6Part11): 3736, 2012 Jun.
Article in English | MEDLINE | ID: mdl-28517136

ABSTRACT

PURPOSE: To study the effect of the virtual wedge and physical wedge filters on the surface and build-up region doses for 6 and 15MV high-energy photon beams for different field sizes and various source to surface distance(SSD). METHODS: The measurements were made in water equivalent (PMMA) solid phantom in the build-up region at various SSD for various field sizes using virtual and physical wedge filters having different angles. A parallel-plate ion chamber (Markus) was used to measure the percent depth doses at surface and buildup region. Plane parallel ion chamber with fixed plate separation on the surface and buildup region would perturbate the dose measured, to get the proper dose over response correction factor was used. RESULTS: The percentage depth dose at surface (PDD0) increased as the field size increased for open, virtual, and physical wedged beams. For open, 30 degree physical, and virtual wedged beams, the surface doses were found to be 15.4%, 11.2%, and 15.2% with 6-MV photons and 11.2%, 9.4%, 11.2% with 15-MV photons, respectively, at 10 × 10 cm2 field size at 100cm SSD.As SSD increases percentage depth dose at surface (PDD0) decreases for open,physical and virtual wedge field. CONCLUSIONS: Percentage depth dose at surface (PDD0) of virtual wedged beams were similar to those of open beams. PDD0 of physical wedged beams were lower than those of open and virtual wedged beams. Surface doses for both PW and VW increases with field size and small increase in surface dose for both PW and VW fields as wedge angle increases especially for large fields.

20.
Med Phys ; 39(6Part12): 3737-3738, 2012 Jun.
Article in English | MEDLINE | ID: mdl-28517808

ABSTRACT

PURPOSE: To evaluate impact on surface dose, Depth of dose maximum (dmax) and depth dose distribution due to physical wedge filters for different wedge angle were studied for 6MV flattened (6MV FB) and 7MV unflattened (7MV UFB) photon beams. METHODS: The flattening filter and primary collimator are the major sources of producing the scattered radiation and these parameters affect the surface dose, dmax and dose distribution. In this study, open fields surface dose, dmax and depth dose distribution values were compared with physical wedge filter for 6MV FB and 7MV UFB .The measurement carried out in Siemens - ARTISTE linear accelerator with diode detector along the central axis of the beam at 100 cm source to surface distance using IBA blue water phantom for 6MV FB and 7MV UFB x-ray beams. RESULTS: The surface dose increased as the field size increased for open and physical wedge fields for 6MV FB and 7MV UFB beams. For open fields, Surface doses relative to the dose at dmax ranged from 0.443 to 0.569 and 0.463 to 0.668 for field sizes of 5 × 5 to 20×20 cm2 for the 7MV UFB and 6MV FB beam respectively. The measured surface dose for 150, 300,450 and 600 wedge field values are 0.396 to 0.504, 0.366 to 0.484, 0.342 to 0.464 and 0.347 to 0.47 respectively for 7MV UFB and 0.424 to 0.566, 0.398 to 0.555, 0.3860 to 0.5430 and 0.389 to 0.55 respectively for 6MV FB. CONCLUSIONS: We found that dmax of wedged beams were higher than those open beams for field size up to 10 × 10 cm2 , Surface doses of wedged beams were lower than those of open beams for 7MV UFB and 6MV FB. Surface dose of the 7MV UFB were lower than the 6MV FB for open and wedged beams.