Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cancer Biother Radiopharm ; 34(1): 24-32, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30277805

ABSTRACT

OBJECTIVE: This article describes the preparation of a 170Tm source by chemical deposition technique, its encapsulation in a titanium holder, and preliminary quality evaluation for potential utility as a brachytherapy source. METHODS: The procedure consisted of electrodeposition of Ni on a Cu wire followed by chemical deposition of 170Tm on it. Influence of feed solution pH, carrier Tm concentration, and reaction time were studied for optimum deposition of 170Tm on substrate. After sealing the source core in a titanium capsule, quality control tests were performed. Distribution of 170Tm on substrate was evaluated by autoradiography. Inactive Tm source was characterized by scanning electron microscope (SEM) and energy-dispersive X-ray (EDS) analyses. RESULTS: Under optimized conditions (pH 5, 10 µg Tm carrier, 5 h), 170Tm source core could be prepared by deposition of >95% of 170Tm radioactivity on substrate. Swipe tests and immersion tests on encapsulated sources confirmed that removable radioactivity and radioactivity leakage levels were within stipulated limits. Autoradiography of 170Tm source confirmed uniformity of radioactivity distribution. While SEM analysis confirmed good adhesion of Tm on substrate, EDS analysis confirmed elemental constituents of the Tm-deposited substrate. CONCLUSION: The objective of preparing a 170Tm source by chemical deposition for potential brachytherapy applications could be successfully achieved.


Subject(s)
Brachytherapy/instrumentation , Radioisotopes/chemistry , Thulium/chemistry , Autoradiography , Brachytherapy/methods , Copper/chemistry , Electroplating/methods , Hydrogen-Ion Concentration , Nickel/chemistry , Quality Assurance, Health Care , Titanium/chemistry
2.
Appl Radiat Isot ; 70(1): 51-8, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21820904

ABSTRACT

A chromatographic (99)Mo/(99m)Tc generator for industrial applications has been developed using alumina microspheres synthesized through sol-gel process to obtain (99m)Tc in both aqueous and non-aqueous media. The sorbent was mesoporous, mechanically strong and possessed high surface area. (99m)Tc could be eluted from generator system using either acetone or 0.9% NaCl solution with appreciably high yields and high radiochemical as well as radionuclidic purity. The facile, versatile generator provides an efficient way to access (99m)Tc at industrial sites for radiotracer applications.


Subject(s)
Aluminum Oxide/chemistry , Industry/instrumentation , Molybdenum/chemistry , Radioisotopes/chemistry , Radionuclide Generators/instrumentation , Technetium/chemistry , Equipment Design , Equipment Failure Analysis , Isotope Labeling/methods , Microspheres
SELECTION OF CITATIONS
SEARCH DETAIL
...