Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Sci Rep ; 13(1): 14948, 2023 09 11.
Article in English | MEDLINE | ID: mdl-37696834

ABSTRACT

Novel CuO/Ag nanocomposites added zeolite (CAZ) were successfully fabricated, and their effectiveness as an antibacterial on S. aureus and MB removal was evaluated. EDX, XRD, and FTIR confirm the presence of the elemental compositions of CAZ. Friable CuO nanorods (10-70 nm in diameter) existed on the surface of the zeolite. Pure zeolite had a higher band gap (5.433 eV) and lower MB removal efficiency than CAZ. The adsorption method by CAZ was more effective at removing MB than photodegradation. 0.10 CAZ had the highest removal effectiveness (~ 99%) and adsorption capacity (~ 70.4 mg g-1) of MB. The inhibitory zone diameter for 0.005 CAZ against S. aureus was 20 mm, while 0.01 CAZ had a diameter of 17 mm. Azithromycin, ceftriaxone, and erythromycin antibiotics demonstrated lower or no efficacy against S. aureus than CAZ. Significant antibacterial activities and wastewater treatment were achieved by CAZ. The combination of photodegradation and adsorption enhanced pollutant removal. It will be interesting to study further the optimal molar ratio for MB removal (0.10 CAZ) in future investigations.


Subject(s)
Nanocomposites , Zeolites , Staphylococcus aureus , Anti-Bacterial Agents/pharmacology
2.
Sci Rep ; 13(1): 10314, 2023 Jun 26.
Article in English | MEDLINE | ID: mdl-37365289

ABSTRACT

ZnS quantum dots (QDs) were fabricated using the co-precipitation technique with no capping agent. The effects of different annealing temperatures (non-annealed, 240 °C and 340 °C for 2 h) on the structural and optical characteristics of ZnS QDs are reported. The samples were examined by XRD, TEM, PL, FTIR, and UV-Vis. An increase in annealing temperature led to an increase in the dot size and a lowering of the energy band gap (EG). The average crystallite size, D of ZnS was between 4.4 and 5.6 nm. The ZnS QDs showed a band gap of 3.75, 3.74 and 3.72 eV for non-annealed, 240 °C, and 340 °C annealed samples. The reflection spectra increased in the visible light and decreased in UV region with an increase in annealing temperature. This work showed that the band gap and size of ZnS QDs could be tuned by varying the annealing temperature.

3.
Sci Rep ; 11(1): 11948, 2021 Jun 07.
Article in English | MEDLINE | ID: mdl-34099823

ABSTRACT

In this work we have tried to prepare Ni and Ag doped ZnO nanopowders using the sol gel technique. The influence of Ni and Ag (1, 3 and 5 mol.%) on the crystalline structure and optical properties of ZnO was investigated. The samples were characterized by XRD, FTIR and UV-visible spectrophotometer. XRD patterns confirmed the wurtzite formation of doped and undoped ZnO nanopowders. The average crystallite sizes of the prepared samples found from XRD were 19 nm for undoped ZnO, from 17 to 22 nm for Ni-ZnO and from 19 to 26 nm for Ag-ZnO. The average crystallite size of Ag-ZnO increased with increasing Ag contents. Different optical properties of Ni-ZnO and Ag-ZnO nanopowders were observed for different Ni and Ag content. The band gaps of Ni-ZnO and Ag-ZnO nanopowders were lower than that of the undoped ZnO (3.1 eV). The band gaps of Ag-ZnO were lower than that of Ni-ZnO. The optical properties of ZnO were enhanced by Ni (mol.%) in the UV region and by Ag (3 and 5 mol.%) in the visible region.

4.
J Diabetes Complications ; 21(6): 381-6, 2007.
Article in English | MEDLINE | ID: mdl-17967711

ABSTRACT

BACKGROUND: Although angiography is the gold standard for coronary imaging, its efficacy in outlining diffuse coronary atherosclerosis in diabetic patients remains questionable. We aimed to compare quantitative cineangiographic analysis (QCA) with three-dimensional intravascular ultrasound (IVUS) imaging in type 2 diabetic patients with coronary artery disease. METHODS: IVUS runs of 104 significant coronary lesions in 88 diabetic patients were performed. Arterial remodeling index was calculated as vessel area at minimal lumen area divided by mean reference vessel area. RESULTS: No difference between the two analysis modes was shown for lesion length and minimal lumen diameter, whereas a significant discrepancy between QCA and IVUS was found for diameter stenosis (10 +/- 9% vs. 41 +/- 8%; P<.001) and vessel diameter (3.01 +/- 0.66 vs. 4.53 +/- 0.70 mm; P<.001). A significant difference on arterial remodeling at lesion site was found between insulin-treated diabetic patients and non-insulin-treated diabetic patients (remodeling index: 0.98 +/- 0.16 vs. 1.07 +/- 0.21; P=.04). CONCLUSIONS: Coronary angiographic diagnosis in diabetic patients may be distorted due to a large plaque burden over longer vessel segments and the resulting absence of plaque-free reference segments. This distortion was found to be more pronounced in QCA analysis requiring a reference diameter, whereas volumetric IVUS imaging illustrated coronary artery dimensions more accurately according to anatomic structures. Constrictive arterial remodeling was observed more frequently in type 2 diabetic patients treated with insulin.


Subject(s)
Atherosclerosis/pathology , Coronary Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Diabetes Mellitus, Type 2/diagnostic imaging , Diabetic Angiopathies/diagnostic imaging , Aged , Algorithms , Angioplasty, Balloon, Coronary , Atherosclerosis/diagnostic imaging , Body Mass Index , Coronary Angiography , Diabetes Mellitus, Type 2/complications , Female , Humans , Male , Middle Aged , Smoking , Smoking Cessation , Ultrasonography, Interventional
5.
Radiother Oncol ; 78(1): 60-6, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16309769

ABSTRACT

BACKGROUND: We report a double-blind, randomized clinical trial of intracoronary beta-radiation for prevention of restenosis after stent implantation in native coronary de novo lesions in diabetic patients. METHODS: After successful stent implantation in native coronary de novo lesions, 106 lesions in 89 diabetic patients were randomly allocated to treatment with beta-radiation with 18 Gy at 1 mm vessel depth (n = 53) or placebo treatment (n = 53). RESULTS: Angiographic analysis at 9 month follow-up revealed a late lumen loss of 0.7+/-0.9 mm in the radiotherapy group versus 1.2+/-0.8 mm in the control group at the injured segment (P = 0.006), 0.9+/-1.0 versus 1.3+/-0.7 mm at the radiated segment (P = 0.02), and 0.9+/-1.0 versus 1.3+/-0.7 mm at the target segment (P = 0.04) (defined as active source length plus 5mm on proximal and distal sites). Binary restenosis rates were significantly lower in the radiation group in all subsegments (injured segment: 10.9 versus 37.3%, P = 0.003; radiated segment: 21.7 versus 49.0%, P = 0.005; target segment: 23.9 versus 49.0%, P = 0.01). Target lesion revascularization for restenosis was required in nine lesions (17.6%) in the radiotherapy group versus 18 (34.0%) in the placebo group (P = 0.05). Late thrombosis occurred in four radiated patients (after premature discontinuation of antiplatelet therapy in all), resulting in a major adverse clinical event rate of 37.2% in the brachytherapy group versus 38.6% in the placebo group (P = ns). CONCLUSIONS: In diabetic patients with de novo coronary lesions, intracoronary radiation after stent implantation significantly reduced restenosis. However, this clinical benefit was reduced by the frequent occurrence of late thrombosis.


Subject(s)
Brachytherapy , Coronary Disease/radiotherapy , Coronary Restenosis/prevention & control , Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 2/complications , Aged , Angioplasty, Balloon, Coronary , Beta Particles/therapeutic use , Brachytherapy/adverse effects , Coronary Disease/complications , Coronary Disease/therapy , Double-Blind Method , Female , Follow-Up Studies , Humans , Male , Middle Aged , Platelet Membrane Glycoprotein IIb/therapeutic use , Prospective Studies , Regression Analysis , Stents , Strontium Radioisotopes/therapeutic use , Treatment Outcome , Yttrium/therapeutic use
6.
Int J Cardiol ; 104(3): 269-74, 2005 Oct 10.
Article in English | MEDLINE | ID: mdl-16186055

ABSTRACT

BACKGROUND: Allograft coronary artery disease (CAD) remains the main factor responsible for late graft loss. This analysis describes data on incidence and progression of allograft CAD at our institute, as well as our experience with coronary interventions in heart transplant recipients. METHODS: Angiographic results of cardiac transplant patients undergoing coronary angiography were prospectively selected and analyzed. Angiographic outcome at follow-up were assessed for all coronary revascularizations in denovo lesions. RESULTS: Four hundred thirty-two coronary angiographies were performed in a total of 246 patients. Seventy-six patients (30.9%) showed angiographic evidence of CAD with %DS>50%, of which 48 patients revealed significant stenosis with %DS>70% (19.5%). Within the first 5 years after the transplantation, 10.1% show angiographic signs of a CAD; at the time of 10.1 years, 50% of all heart transplant patients have developed a CAD. Once a CAD with %DS between 50% and 60% has evolved, the disease shows fast progression. Coronary intervention was performed in 28 vessels at an average time of 9.5 years after heart transplantation. Follow-up angiography was available for 27 vessels (1 death before re-angiography) within a mean follow-up period of 19.3 months. Binary restenosis was found in 7 out of 27 vessels (25.9%). Comparison of the occurrence of total occlusion in vessels with %DS>70% which were not revascularized to the occurrence of MACE after successful revascularization revealed better long term results in the group of patients with coronary intervention (p=0.04). CONCLUSION: Whereas coronary artery disease is found in rare cases within the first 5 years after heart transplantation, the incidence grows in exponential manner after this period. Mid-term follow-up after coronary intervention exhibit restenosis-rates which are similar to the ones of other high risk patients. Comparison of coronary intervention versus conservative treatment in vessels with %DS>70% show significant better mid-term outcome in the interventional group.


Subject(s)
Coronary Artery Disease/therapy , Heart Transplantation , Adult , Aged , Angioplasty, Balloon, Coronary , Austria/epidemiology , Blood Vessel Prosthesis Implantation , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/epidemiology , Coronary Stenosis/therapy , Disease Progression , Female , Follow-Up Studies , Humans , Incidence , Male , Middle Aged , Prospective Studies , Stents , Treatment Outcome
7.
J Interv Cardiol ; 17(3): 143-9, 2004 Jun.
Article in English | MEDLINE | ID: mdl-15209576

ABSTRACT

PURPOSE: The purpose of this analysis was to evaluate if overdosage during intracoronary irradiation due to overlapped source stepping may result in long-term morphologic changes in vessel anatomy. METHODS: Baseline angiograms of patients with in-stent restenosis undergoing coronary reintervention followed by intracoronary irradiation with source stepping were analyzed. Overlapping was considered present for the segment with overlapped reference isodose length (RIL) (RIL = segment with > or = 90% of reference dose at 1 mm vessel wall depth). Baseline and 6-months follow-up volumetric intravascular ultrasound (IVUS) analysis were performed for the overlapped segment and for proximal and distal segments of equal length. RESULTS: Overlapping was found in six patients (three patients: (32)P treatment; three patients: (90)Sr/Y treatment); final analysis was performed in four patients. Comparison of the baseline and follow-up IVUS volumetric parameters revealed no significant change in lumen or vessel volumes at segments of overlaps in comparison to proximal and distal reference segments. CONCLUSION: Increased dosage due to overlapping during source stepping is not associated with morphologic changes in vessel anatomy at follow-up.


Subject(s)
Coronary Restenosis/therapy , Coronary Vessels/radiation effects , Phosphorus Radioisotopes/administration & dosage , Strontium Radioisotopes/administration & dosage , Angioplasty, Balloon , Coronary Vessels/diagnostic imaging , Dose-Response Relationship, Radiation , Humans , Imaging, Three-Dimensional , Phosphorus Radioisotopes/adverse effects , Prospective Studies , Strontium Radioisotopes/adverse effects , Ultrasonography, Interventional
8.
Coron Artery Dis ; 14(5): 409-12, 2003 Aug.
Article in English | MEDLINE | ID: mdl-12878907

ABSTRACT

BACKGROUND: Biodegradable stent coatings provide a potential for local drug delivery at the time of vascular injury, while possible tissue toxicity is avoided through constant degradation, leaving behind a bare metal stent. DESIGN: Serial three-dimensional (3D) intravascular ultrasonographic results on bare Megaflex stents and biodegradable polymer-coated Megaflex stents (Hyper stents) (Eurocor, Bonn, Germany) were compared 1 and 4 weeks after intracoronary implantation in pigs. METHODS: Under general anaesthesia, the left anterior descending and circumflex coronary arteries of domestic pigs were stented with Megaflex and Hyper stents, using right femoral artery access. Control coronary angiography and intravascular ultrasonography (IVUS) were performed 1 and 4 weeks after stent implantation using left femoral artery access and right carotid artery access. After recording of angiographic and IVUS data, the pigs were allowed to recover. RESULTS: The 1- and 4-week IVUS follow-ups revealed less neointima formation with Hyper stents than with Megaflex stents: 1-week intimal volume, 11.8+/-0.93 compared with 15.02+/-4.18 mm3, P=0.065; intimal area, 0.81+/-0.06 compared with 1.1+/-0.16 mm2, P =0.003; maximal intimal thickness, 0.12+/-0.01 compared with 0.14+/-0.02 mm, P =0.049; 4-week intimal volume, 12.4+/-1.77 compared with 27.32+/-12.79 mm3, P =0.016; intimal area, 0.82+/-0.12 compared with 1.95+/-0.65 mm2, P=0.003; and maximal intimal thickness, 0.13+/-0.04 compared with 0.30+/-0.10 mm, P=0.003. CONCLUSIONS: Implantation of biodegradable polymer-coated (Hyper) stents results in significantly less neointima formation 1 and 4 weeks after intracoronary implantation than with bare Megaflex stents. Taking advantage of the good collateralization of femoral and carotid arteries of pigs, the use of different arterial accesses allows serial angiographic and 3D IVUS measurements on neointimal development without sacrificing the animals.


Subject(s)
Coronary Vessels/diagnostic imaging , Stents , Ultrasonography, Interventional , Animals , Coronary Angiography , Coronary Vessels/pathology , Hyperplasia , Pilot Projects , Swine , Tunica Intima/pathology
9.
Coron Artery Dis ; 13(5): 263-8, 2002 Aug.
Article in English | MEDLINE | ID: mdl-12394650

ABSTRACT

BACKGROUND: Diabetic patients show an increased incidence of restenosis after coronary angioplasty than non-diabetic patients. This may be because of differences in the mechanism of lumen gain during coronary revascularization in this population cohort. DESIGN: This study analyses the mechanism of lumen gain during coronary stent deployment in diabetic patients compared with non-diabetic patients with intravascular ultrasound (IVUS). METHODS: IVUS images were obtained prior to and after revascularization in 26 diabetic and 97 non-diabetic patients. The external elastic membrane cross-sectional area (EEM) and lumen cross-sectional area (LA) were measured. Plaque area (PA) was calculated as EEM minus LA. Differences between pre- and post-LA (deltaLA), EEM (deltaEEM) and PA (deltaPA) were calculated. RESULTS: Pre-interventional PA (diabetic patients: 12.4 +/- 4.4 mm2 compared with non-diabetic patients: 10.7 +/- 3.6 mm2, = 0.04) and pre-interventional EEM (15.5 +/- 4.4 mm2 compared with 13.6 +/- 3.7 mm2 respectively, P = 0.02) were larger in the diabetic group. Postinterventional PA (10.2 +/- 3.2 mm2 compared with 8.0 +/- 3.4 mm2, P = 0.004) was also larger and postinterventional LA (6.3 +/- 2.2 mm2 compared with 7.4 +/- 2.4 mm2 = 0.04), deltaEEM (0.9 +/- 1.8 mm2 compared with 1.8 +/- 1.8 mm2 P = 0.04) and deltaLA (3.1 +/- 1.6 mm2 compared with 4.2 +/- 2.2 mm2, P = 0.03) were smaller in the diabetic group. The diabetic group exhibited longer lesion lengths (P = 0.04) and a higher inflation pressure was used during revascularization in this patient cohort (P = 0.02). CONCLUSION: Diabetic patients have less reduction of PA during revascularization and because the vessel wall cannot be stretched outwards despite higher inflation pressure, postinterventional LA remains smaller than in the non-diabetic population cohort. This might be a rudiment for consideration of different treatment strategies such as cutting balloon or atherectomy prior to stenting in this population group in order to achieve better procedural outcome.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease/pathology , Coronary Artery Disease/therapy , Coronary Vessels/pathology , Diabetic Angiopathies/pathology , Diabetic Angiopathies/therapy , Stents , Ultrasonography, Interventional , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Diabetic Angiopathies/diagnostic imaging , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...