Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Eur J Radiol ; 166: 110981, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37478655

ABSTRACT

PURPOSE: To assess image quality and detectability of interstitial lung changes using multiple radiation doses from the same chest CT scan of patients with suspected interstitial lung disease (ILD). METHOD: Retrospective study of consecutive adult patients with suspected ILD receiving unenhanced chest CT as single-energy dual-source acquisition at 100 kVp (Dual-split mode). 67% and 33% of the overall tube current time product were assigned to tube A and B, respectively. 100%-dose was 2.34 ± 0.97 mGy. Five different radiation doses (100%, 67%, 45%, 39%, 33%) were reconstructed from this single acquisition using linear-blending technique. Two blinded radiologists assessed reticulations, ground-glass opacities (GGO) and honeycombing as well as subjective image noise. Percentage agreement (PA) as compared to 100%-dose were calculated. Non-parametric statistical tests were used. RESULTS: A total of 228 patients were included (61.2 ± 14.6 years,146 female). PA was highest for honeycombing (>96%) and independent of dose reduction (P > 0.8). PA for reticulations and GGO decreased when reducing the radiation dose from 100% to 67% for both readers (reticulations: 83.3% and 93.9%; GGO: 87.7% and 79.8% for reader 1 and 2, respectively). Additional dose reduction did not significantly change PA for both readers (all P > 0.05). Subjective image noise increased with decreasing radiation dose (Spearman Rho of ρ = 0.34 and ρ = 0.53 for reader 1 and 2, respectively, P < 0.001). CONCLUSIONS: Radiation dose reduction had a stronger impact on subtle interstitial lung changes. Detectability decreased with initial dose reduction indicating that a minimum dose is needed to maintain diagnostic accuracy in chest CT for suspected ILD.


Subject(s)
Lung Diseases, Interstitial , Tomography, X-Ray Computed , Adult , Humans , Female , Retrospective Studies , Radiation Dosage , Tomography, X-Ray Computed/methods , Lung Diseases, Interstitial/diagnostic imaging , Lung/diagnostic imaging
2.
Diagnostics (Basel) ; 12(11)2022 Nov 07.
Article in English | MEDLINE | ID: mdl-36359558

ABSTRACT

Purpose: To assess the impact of virtual-monoenergetic-image (VMI) energies on the diagnosis of pulmonary embolism (PE) in photon-counting-detector computed-tomography (PCD-CT). Methods: Eighty patients (median age 60.4 years) with suspected PE were retrospectively included. Scans were performed on PCD-CT in the multi-energy mode at 120 kV. VMIs from 40−70 keV in 10 keV intervals were reconstructed. CT-attenuation was measured in the pulmonary trunk and the main branches of the pulmonary artery. Signal-to-noise (SNR) ratio was calculated. Two radiologists evaluated subjective-image-quality (noise, vessel-attenuation and sharpness; five-point-Likert-scale, non-diagnostic−excellent), the presence of hardening artefacts and presence/visibility of PE. Results: Signal was highest at the lowest evaluated VMI (40 keV; 1053.50 HU); image noise was lowest at the highest VMI (70 keV; 15.60 HU). Highest SNR was achieved at the lowest VMI (p < 0.05). Inter-reader-agreement for subjective analysis was fair to excellent (k = 0.373−1.000; p < 0.001). Scores for vessel-attenuation and sharpness were highest at 40 keV (both:5, range 4/3−5; k = 1.000); scores for image-noise were highest at 70 keV (4, range 3−5). The highest number of hardening artifacts were reported at 40 keV (n = 22; 28%). PE-visualization was rated best at 50 keV (4.7; range 4−5) and decreased with increasing VMI-energy (r = −0.558; p < 0.001). Conclusions: While SNR was best at 40 keV, subjective PE visibility was rated highest at 50 keV, potentially owing to the lower image noise and hardening artefacts.

3.
Tex Heart Inst J ; 42(2): 169-71, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25873833

ABSTRACT

Pulmonary arteriovenous fistula is a rare disease. To the best of our knowledge, prenatal diagnosis of a fistula between the left pulmonary artery and the left pulmonary vein has not been described in the medical literature. We report a case of the prenatal diagnosis of a left pulmonary artery-to-pulmonary vein fistula, followed by successful neonatal surgical repair.


Subject(s)
Arteriovenous Fistula/diagnosis , Arteriovenous Fistula/surgery , Fetal Diseases/diagnosis , Heart Defects, Congenital/surgery , Prenatal Diagnosis , Pulmonary Artery/abnormalities , Pulmonary Veins/abnormalities , Adult , Female , Humans , Infant, Newborn , Pulmonary Artery/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...