Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Article in Japanese | MEDLINE | ID: mdl-22516599

ABSTRACT

DIS has not yet been implemented in Japan as of 2011. Therefore, even if risk was negligible, medical institutions have to entrust radioactive temporal waste disposal to Japan Radio Isotopes Association (JRIA) in the current situation. To decide whether DIS should be implemented in Japan or not, cost-saving effect of DIS was estimated by comparing the cost that nuclear medical facilities pay. By implementing DIS, the total annual cost for all nuclear medical facilities in Japan is estimated to be decreased to 30 million yen or less from 710 million yen. DIS would save 680 million yen (96%) per year.


Subject(s)
Cost Savings , Faculty, Medical , Radioactive Waste/economics , Radioactivity , Refuse Disposal/economics , Japan , Nuclear Medicine/economics
2.
Appl Opt ; 50(30): 5834-41, 2011 Oct 20.
Article in English | MEDLINE | ID: mdl-22015412

ABSTRACT

A technique to study the drying of paints, based on phase-shifting digital holography, is presented. The technique is applied to the drying process of solvent-based paint on a three-dimensional surface at different substrate temperatures. For processing the data, a cross-correlation function and phase change derived from reconstructed complex amplitudes are calculated to visualize and to evaluate the local variations in the dryness of paint. The relationship between the optical signal obtained by the holographic method and the actual microscopic variations occurring in the paint film is also investigated using the gravimetric technique and a microscope. It is shown that the holographic technique can determine the stationary state of a painted surface corresponding to the end of the falling rate period in the drying process. The holographic technique detects mainly the activity on the surface and is applicable to assessment of the early drying process of paint.

3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 65(5): 631-7, 2009 May 20.
Article in Japanese | MEDLINE | ID: mdl-19498253

ABSTRACT

A rational clearance system for medical radioactive waste has not yet been established in Japan. As Europe and USA's ways, the establishment of DIS that medical radioactive waste what are kept in storage room for more than decided period each nuclide except from regulation of radiation's control. The purpose of this report is to clarify the problems with the establishment of DIS in Japan through a literature review of the experience in Europe and the USA and previous research that has been reported in Japan. To establish the DIS system, the radiation control system in nuclear medicine should be rebuilt and put into effect.


Subject(s)
Medical Waste Disposal/methods , Radioactive Waste , Bibliographies as Topic , Europe , Japan , Korea
4.
Appl Opt ; 45(29): 7610-6, 2006 Oct 10.
Article in English | MEDLINE | ID: mdl-17068593

ABSTRACT

Surface contouring by phase-shifting digital holography is proposed and verified by experiments and numerical simulations. Digital holograms are recorded before and after mode hopping of a laser diode subject to current tuning, and the difference of the reconstructed phases at each wavelength is computed to deliver surface contours of a diffusely reflecting surface. Since normal incidence on the object is employed, the method does not need the removal of the tilt component and is free from the shadowing effect as advantages over the dual-incidence method proposed before by the first author.

5.
Appl Opt ; 45(5): 975-83, 2006 Feb 10.
Article in English | MEDLINE | ID: mdl-16512541

ABSTRACT

We describe data compression in phase-shifting digital holography. We demonstrate by experimentation that an image of a diffusely reflecting object can be reconstructed only by phase data of the derived complex amplitude. It is shown that reduction of the bit depth of the phase data does not seriously damage the image even down to 1 bit. We observe enhancement of halo in the image with low bit depths. This tendency is verified quantitatively by a one-dimensional simulation. Our procedure for smoothing the images that result from the data-compression methods is shown to be effective.

6.
Appl Opt ; 44(7): 1216-25, 2005 Mar 01.
Article in English | MEDLINE | ID: mdl-15765702

ABSTRACT

We discuss quantization effects of hologram recording on the quality of reconstructed images in phase-shifting digital holography. We vary bit depths of phase-shifted holograms in both numerical simulation and experiments and then derived the complex amplitude, which is subjected to Fresnel transformation for the image reconstruction. The influence of bit-depth limitation in quantization has been demonstrated in a numerical simulation for spot-array patterns with linearly varying intensities and a continuous intensity object. The objects are provided with uniform and random phase modulation. In experiments, digital holograms are originally recorded at 8 bits and the bit depths are changed to deliver holograms at bit depths of 1 to 8 bits for the image reconstruction. The quality of the reconstructed images has been evaluated for the different quantization levels.

7.
Opt Lett ; 29(14): 1668-70, 2004 Jul 15.
Article in English | MEDLINE | ID: mdl-15309854

ABSTRACT

A new algorithm that allows for reconstruction of digital holograms with adjustable magnification is proposed. The algorithm involves two reconstruction steps implemented by a conventional single Fourier-transform algorithm. The advantages of the algorithm lie in its adaptability to various object sizes and recording distances as well as in its capability to maintain the pitch of a reconstructed image, independent of the reconstruction distance and wavelength for objects larger than a CCD. The feasibility of the algorithm is demonstrated by experiments. The algorithm is especially useful for reconstructing color holograms and for metrological applications.

8.
Appl Opt ; 41(22): 4497-502, 2002 Aug 01.
Article in English | MEDLINE | ID: mdl-12153077

ABSTRACT

A wavelength-scanning heterodyne interference confocal microscope quickly accomplishes the simultaneous measurement of the thickness and the refractive index of a sample by detection of the amplitude and the phase of the interference signal during a sample scan. However, the measurement range of the optical path difference (OPD) that is obtained from the phase changes is limited by the time response of the phase-locked loop circuit in the FM demodulator. To overcome this limitation and to improve the accuracy of the separation measurement, we propose an OPD detection using digital signal processing with a Hilbert transform. The measurement range is extended approximately five times, and the resolution of the OPD is improved to 5.5 from 9 microm without the electrical noise of the FM demodulator circuit. By applying this method for simultaneous measurement of thickness and the refractive index, we can measure samples 20-30-microm thick with refractive indices between 1 and 1.5.

9.
Appl Opt ; 41(13): 2414-9, 2002 May 01.
Article in English | MEDLINE | ID: mdl-12009150

ABSTRACT

A wavelength-scanning heterodyne interference confocal microscope has proved to provide the tomographic image of the refractive indices of transparent and turbid media on the scale of geometrical depth when weakly reflected light with an optical power as low as of the order of 10(-14) W is used. The refractive indices of the transparent object and the turbid media were measured with accuracies of -0.5% and approximately 3%, respectively. This imaging method is advantageous for evaluating quantitative refractive indices and internal structures.

10.
Opt Lett ; 27(13): 1108-10, 2002 Jul 01.
Article in English | MEDLINE | ID: mdl-18026376

ABSTRACT

Digital holography with a three-wavelength laser and a color CCD has been demonstrated. With the phase shifting of the reference beam, in-line holograms for three wavelengths are recorded simultaneously for derivation of the complex amplitude at each wavelength, and then the three monochromatic images are reconstructed and combined into full-color images in the computer. Laser power variation for wavelengths can be compensated for in the reconstruction process. We have compared the images reconstructed by two algorithms using a single Fourier transformation and a convolution with each other by both experiments and numerical simulations. Phase-shifting errors arising at two of the three wavelengths have proved not to cause serious deterioration of the reconstructed images.

11.
Opt Lett ; 27(16): 1403-5, 2002 Aug 15.
Article in English | MEDLINE | ID: mdl-18026460

ABSTRACT

Multiwavelength recording and reconstruction of a three-dimensional object are realized by use of phase-shifting digital holography. Red, green, and blue lines emitted from a white-light He-Cd laser are used for one-step recording of the complex amplitude of the object with a color CCD camera, in which a phase shift is introduced with an achromatic phase shifter based on the geometric phase. Three color images are reconstructed and successfully combined in a computer by use of Fresnel transformation based on a convolution.

SELECTION OF CITATIONS
SEARCH DETAIL
...