Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 269
Filter
1.
Heart Vessels ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38710808

ABSTRACT

BACKGROUND: Severe aortic valve stenosis (AS) and atrial fibrillation (AF) are risk factors of hemodynamic instability in heart failure (HF) management due to low cardiac output, respectively. Therefore, the treatment of HF due to severe AS complicated with AF is anticipated to be difficult. Tolvaptan, a vasopressin V2 receptor inhibitor, is effective in controlling acute decompensated heart failure (ADHF) with hemodynamic stability. However, its clinical efficacy against ADHF caused by AS with AF remains to be determined. METHODS: Clinical information (from September 2014 to December 2017) of 59 patients diagnosed with ADHF due to severe AS (20 patients with AF; 39 patients with sinus rhythm [SR]) was obtained from the LOHAS registry. The registry collected data from seven hospitals and assessed the short-term effects of tolvaptan in patients hospitalized for ADHF with severe AS. We attempted to identify clinical differences from baseline up to 4 days, comparing patients with AF (AF group) versus those with SR (SR group). RESULTS: There were no significant differences between the groups in age (83.7 ± 4.5 vs. 85.8 ± 6.9 years, respectively; p = 0.11) and aortic valve area (0.60 [0.46-0.73] vs. 0.56 [0.37-0.70] cm2, respectively; p = 0.50). However, left atrial volume was larger (104 [85-126] vs. 87 [64-103] mL, respectively; p < 0.01), whereas stroke volume was lower (51.6 ± 14.8 vs. 59.0 ± 18.7 mL, respectively; p = 0.08) in the AF group versus the SR group. Body weight decreased daily from baseline up to day 4 in both groups (from 55.4 to 53.2 kg [p < 0.01] and from 53.5 to 51.0 kg [p < 0.01], respectively) without change in heart rate. Notably, the systolic blood pressure decreased slightly in the AF group after 2 days of treatment with tolvaptan. CONCLUSIONS: Short-term treatment with tolvaptan improved HF in patients hospitalized for severe AS, regardless of the presence of AF or SR. After achieving sufficient diuresis, a slight decrease in blood pressure was observed in the AF group, suggesting an appropriate timeframe for safe and effective use of tolvaptan.

2.
Am J Cardiol ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38797196

ABSTRACT

The hemodynamic performance of self-expandable valves (SEV) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are so far available regarding the relationship between the size of SEV and clinical outcomes. This study sought to evaluate the impact of prosthesis size on adverse events after TAVR using SEV. We retrospectively analyzed 1400 patients (23mm SEV: 13.6%) who underwent TAVR using SEV at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small (23mm SEV) and larger-size (26 or 29mm SEV) (16.8% vs. 13.9%, log-rank P = 0.29). The size of SEV was not associated with higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution-HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution-HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including post-procedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable mid-term clinical outcomes as compared to larger-size SEVs, even if the prosthesis-patient mismatch was observed after TAVR.

3.
Circ J ; 2024 May 17.
Article in English | MEDLINE | ID: mdl-38763735

ABSTRACT

BACKGROUND: Limited data are available regarding clinical outcomes after percutaneous left atrial appendage closure using WATCHMAN FLX (WM-FLX) and WATCHMAN-2.5 (WM2.5) devices in Asian patients.Methods and Results: Data of 1,464 consecutive patients (WM-FLX, n=909; WM2.5, n=555) were extracted from a Japanese multicenter registry, and clinical data were compared between the 2 groups. No in-hospital deaths, periprocedural stroke, or device embolization occurred. Procedural success was significantly higher in the WM-FLX than WM2.5 group (95.8% vs. 91.9%; P=0.002) owing to the lower incidence of periprocedural pericardial effusion (0.55% vs. 1.8%; P=0.021). No significant differences in all-cause death, postprocedural stroke, and device-related thrombus were observed between the 2 groups. However, the cumulative bleeding rate at 1 year was substantially lower in the WM-FLX group (7.8% vs. 16.4%; P<0.001). Landmark analysis of bleeding events highlighted lower bleeding rates in the WM-FLX than WM2.5 group within the first 6 months (6.4% vs. 14.8%; P<0.001), with comparable bleeding rates over the 6- to 12-month period (1.5% vs. 3.2%, respectively; P=0.065). CONCLUSIONS: This study demonstrated higher early safety and lower 1-year bleeding rates in the WM-FLX than WM2.5 group. The lower bleeding events with WM-FLX are likely due to multiple factors other than purely difference in devices, such as postprocedural drug regimen.

5.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726714

ABSTRACT

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
6.
ESC Heart Fail ; 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38607328

ABSTRACT

AIMS: A considerable proportion of candidates for transcatheter aortic valve implantation (TAVI) have underlying heart failure (HF) with preserved ejection fraction (HFpEF), which can be challenging for diagnosis because significant valvular heart disease should be excluded before diagnosing HFpEF. This study investigated the long-term prognostic value of the pre-procedural H2FPEF score in patients with preserved ejection fraction (EF) undergoing TAVI. METHODS AND RESULTS: Patients who underwent TAVI between October 2013 and May 2017 were enrolled from the Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation Japanese multicentre registry. After excluding 914 patients, 1674 patients with preserved EF ≥ 50% (median age: 85 years, 72% female) were selected for calculation of the H2FPEF score and were dichotomized into two groups: the low H2FPEF score [0-5 points; n = 1399 (83.6%)] group and the high H2FPEF score [6-9 points; n = 275 (16.4%)] group. Patients with high H2FPEF scores were associated with a higher prevalence of New York Heart Association Functional Class III/IV (59.3% vs. 43.7%, P < 0.001), diabetes (24.4% vs. 18.5%, P = 0.03), and paradoxical low-flow, low-gradient aortic stenosis (15.9% vs. 6.2%, P < 0.001). These patients showed worse prognoses than those with low H2FPEF scores regarding the cumulative 2 year all-cause mortality (26.3% vs. 15.5%, log-rank P < 0.001), cardiovascular mortality (10.5% vs. 5.4%, log-rank P < 0.001), HF hospitalization (16.2% vs. 6.7%, log-rank P < 0.001), and the composite endpoint of cardiovascular mortality and HF hospitalization (23.8% vs. 10.8%, log-rank P < 0.001). After adjustment for several confounders, the high H2FPEF scores were independently associated with increased risk for all-cause mortality [adjusted hazard ratio (HR), 1.48; 95% confidence interval (CI), 1.09-2.00; P = 0.011] and for the composite endpoint of cardiovascular mortality and HF hospitalization (adjusted HR, 1.95; 95% CI, 1.38-2.74; P < 0.001). Subgroup analysis confirmed the excess risk of high H2FPEF scores relative to low H2FPEF scores for the composite endpoint of cardiovascular mortality and HF hospitalization increased with a lower Society of Thoracic Surgeons (STS) score (STS score <8%: adjusted HR, 2.40; 95% CI, 1.50-3.85; P < 0.001; STS score ≥8%: adjusted HR, 1.34; 95% CI, 0.79-2.28; P = 0.28; Pinteraction = 0.030). CONCLUSIONS: The H2FPEF score is useful for predicting long-term adverse outcomes after TAVI, including all-cause mortality, cardiovascular mortality, and HF hospitalization for patients with preserved EF. More aggressive interventions targeting HFpEF in addition to the TAVI procedure might be relevant in patients with high H2FPEF scores, particularly in those with a lower surgical risk.

7.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38660100

ABSTRACT

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

8.
Circ Cardiovasc Interv ; : e013794, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38629311

ABSTRACT

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.

9.
Open Heart ; 11(1)2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38417913

ABSTRACT

OBJECTIVES: The clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS) and concomitant active cancer remain insufficiently explored. This study aimed to assess the midterm outcomes of TAVR in patients diagnosed with AS and active cancer. METHODS: Data from the OCEAN-TAVI, a prospective Japanese registry of TAVR procedures, was analysed to compare prognoses and clinical outcomes in patients with and without active cancer at the time of TAVR. RESULTS: Of the 2336 patients who underwent TAVR from October 2013 to July 2017, 89 patients (3.8%) had active cancer, whereas 2247 did not. Among patients with active cancer, 49 had limited-stage cancer (stage 1 or 2). The prevalent cancers identified before TAVR were colon (21%), prostate (18%), lung (15%), liver (11%) and breast (9%). Although the periprocedural complications and 30-day mortality rates were comparable between the groups, the 3-year survival rate after TAVR was notably lower in patients with active cancer (64.7%) than in those without active cancer (74.7%; p=0.016). Nevertheless, the 3-year survival rate of patients with limited-stage cancer (stage 1 or 2) did not significantly differ from those without cancer (70.6% vs 74.7%, p=0.50). CONCLUSIONS: The patients with active cancer exhibited significantly reduced midterm survival rates. However, no distinct disparity existed in those with limited-stage cancer (stage 1 or 2). Although TAVR is a viable treatment in patients with AS with active cancer, the type and stage of cancer and prognosis should be carefully weighed in the decision-making process.


Subject(s)
Aortic Valve Stenosis , Neoplasms , Transcatheter Aortic Valve Replacement , Male , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Prospective Studies , Time Factors , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Neoplasms/diagnosis
10.
Chem Sci ; 15(6): 1953-1965, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38332834

ABSTRACT

Precise template synthesis will realize three-dimensionally ordered nanoporous graphenes (NPGs) with a spatially controlled seamless graphene structure and fewer edges. These structural features result in superelastic nature, high electrochemical stability, high electrical conductivity, and fast diffusion of gases and ions at the same time. Such innovative 3D graphene materials are conducive to solving energy-related issues for a better future. To further improve the attractive properties of NPGs, we review the template synthesis and its mechanism by chemical vapor deposition of hydrocarbons, analysis of the nanoporous graphene structure, and applications in electrochemical and mechanical devices.

11.
J Clin Med ; 13(3)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38337545

ABSTRACT

Background: Transcatheter edge-to-edge mitral valve repair (TEER) has emerged as a viable approach to addressing substantial secondary mitral regurgitation. In the contemporary landscape where ultimate heart failure-specific therapies, such as cardiac replacement modalities, are available, prognosticating a high-risk cohort susceptible to early cardiac mortality post-TEER is pivotal for formulating an effective therapeutic regimen. Methods: Our study encompassed individuals with secondary mitral regurgitation and chronic heart failure enlisted in the multi-center (Optimized CathEter vAlvular iNtervention (OCEAN)-Mitral registry. We conducted an assessment of baseline variables associated with cardiac death within one year following TEER. Results: Amongst the 1517 patients (median age: 78 years, 899 males), 101 experienced cardiac mortality during the 1-year observation period after undergoing TEER. Notably, a history of heart failure-related admissions within the preceding year, utilization of intravenous inotropes, and elevated plasma B-type natriuretic peptide levels emerged as independent prognosticators for the primary outcome (p < 0.05 for all). Subsequently, we devised a novel risk-scoring system encompassing these variables, which significantly stratified the cumulative incidence of the 1-year primary outcome (16%, 8%, and 4%, p < 0.001). Conclusions: Our study culminated in the development of a new risk-scoring system aimed at predicting 1-year cardiac mortality post-TEER.

14.
J Clin Med ; 12(23)2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38068484

ABSTRACT

BACKGROUND: Individuals with heart failure displaying supra-normal left ventricular ejection fraction (snLVEF) may exhibit less favorable clinical outcomes in contrast to their counterparts with normal left ventricular ejection fraction (nLVEF). The distinctive characteristics and mid-term prognosis of individuals with severe aortic stenosis and snLVEF following transcatheter aortic valve replacement (TAVR) remain enigmatic. METHODS: Among 7393 patients diagnosed with severe aortic stenosis who underwent TAVR between 2013 and 2019 and were enlisted in the optimized transcatheter valvular intervention (OCEAN-TAVI) multicenter registry (UMIN000020423), we selected patients with left ventricular ejection fraction (LVEF) ≥ 50%. snLVEF was defined as LVEF exceeding 65%. We compared the baseline characteristics and assessed three-year post-TAVR mortality and heart failure readmission rates between the snLVEF (LVEF > 65%) and nLVEF cohorts (LVER 50-65%). RESULTS: Our study cohort comprised 5989 patients (mean age 84.4 ± 5.1 years and 1783 males). Among these, 2819 patients were categorized within the snLVEF cohort, while the remaining 3170 were allocated to the nLVEF group. Individuals within the snLVEF cohort were more likely to be female and displayed lower levels of natriuretic peptides, as well as smaller left ventricular dimensions in comparison to their nLVEF counterparts (p < 0.05 for all). The presence of snLVEF emerged as an independent predictor of the three-year composite endpoint relative to nLVEF, with an adjusted hazard ratio of 1.16 (95% confidence interval 1.02-1.31, p = 0.023) after accounting for several potential confounding factors. CONCLUSIONS: snLVEF was relatively common among candidates for TAVR with preserved ejection fraction. Patients harboring snLVEF appear to manifest a distinctive clinical profile and encounter less favorable clinical outcomes following TAVR in contrast to those characterized by nLVEF.

15.
JACC Asia ; 3(5): 766-773, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38094997

ABSTRACT

Background: Transcatheter edge-to-edge repair (TEER) is a less invasive treatment for patients with mitral regurgitation (MR). Limited safety and efficacy data of TEER with MitraClip, including the fourth-generation (G4) system, in a large cohort, are available. Objectives: This study aimed to summarize the initial experience of the TEER system in patients with MR from a large registry in Japan. Methods: The OCEAN (Optimized CathEter vAlvular iNtervention)-Mitral Registry is an ongoing, prospective, investigator-initiated, multicenter, observational registry for patients with primary and secondary MR undergoing transcatheter mitral valve therapies. A total of 21 centers participated in the registry. Patients undergoing TEER were enrolled, and their characteristics, procedural details, and clinical outcomes were recorded. Results: In total, 2,150 patients including 1,605 patients (75.0%) with secondary MR, were enrolled between April 2018 and June 2021. The median age was 80 years, and 43.7% were women. The median device and fluoroscopy times were 60 and 26 minutes, respectively. Those with the G4 system (618/2,150 [28.7%]) were significantly shorter than those with the second generation (G2) system (1,532/2,150 [71.3%]). Overall, 94.6% met acute procedural success without significant differences between the 2 systems (G2 94.7% vs G4 94.6%; P = 0.961). Conclusions: The OCEAN-Mitral registry has demonstrated the short-term outcomes of TEER systems, including the G4 system, in symptomatic patients with primary and secondary MR. The acute procedural success rate in the G2 system was excellent, and that in the G4 system was expected to improve with the multidisciplinary heart valve team approach. (Japanese Registry study of valvular heart diseases treatment and prognosis; UMIN000023653).

16.
Phys Chem Chem Phys ; 25(48): 32972-32978, 2023 Dec 13.
Article in English | MEDLINE | ID: mdl-38019669

ABSTRACT

Nanoporous graphene (NPG) materials have the pronounced electrochemical stability of the seamless graphene structures developed over the 3D space. We revisited the Raman spectra of nanoporous carbons (NPCs) synthesized using θ-/γ-Al2O3 templates and NPGs converted from NPCs by annealing at 1800 °C to identify the type and density of defects. We found that both the NPCs and NPGs mostly consist of single-layered graphene with a few single vacancies and Stone-Wales defects. The density of vacancy defect per hexagon in the graphene sheet is estimated to be 10-2 for NPCs, while the annealing reduced the value to 10-3-10-4 for NPGs. This supports the outstanding chemical and electrochemical stability of the novel porous carbon materials.

17.
Eur Heart J Case Rep ; 7(11): ytad503, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37954569

ABSTRACT

Background: We previously reported a case of successful percutaneous left atrial appendage closure (LAAC) for complex left atrial appendage (LAA) morphology using a handmade double-curve delivery sheath (DS) reshaped by a heat gun. However, whether the reshaped curve was appropriately adjusted as an optimal configuration for this patient's anatomy remained uncertain. Case summary: We established the LAAC procedural simulation model supported by virtual reality (VR) technology. With this VR simulator, the patient's whole heart model with venous access route and atrial septal puncture point of foramen ovale (FO) could be replicated based on the pre-procedural computed tomography image. Multiple views of the VR image provided a deep understanding of the patient-specific anatomy. Additionally, the operators were enabled to perform the virtual LAAC procedure using VR-derived LAAC devices, including various DS types. In the VR simulator, the manually reshaped DS showed better co-axiality from the FO to the LAA orifice than the conventional double-curve DS, resulting in the successful deployment inside the LAA of the VR simulator. However, the perpendicularity of the device towards the LAA orifice of the handmade reshaped DS remained insufficient. The VR simulator suggested that the ideal curve of the DS needed to change relatively posteriorly and have a more aggressive inferior slide than the previously reshaped DS. Discussion: The post-procedural review of the VR simulator confirmed that the sheath reshaping technique helped ensure successful LAAC. Pre-procedural VR simulation may be useful for procedural planning that includes DS reshaping for patients with challenging anatomy undergoing LAAC.

19.
J Am Heart Assoc ; 12(20): e030747, 2023 10 17.
Article in English | MEDLINE | ID: mdl-37815039

ABSTRACT

Background Limited data are available about clinical outcomes and residual mitral regurgitation (MR) after transcatheter edge-to-edge repair in the large Asian-Pacific cohort. Methods and Results From the Optimized Catheter Valvular Intervention (OCEAN-Mitral) registry, a total of 2150 patients (primary cause of 34.6%) undergoing transcatheter edge-to-edge repair were analyzed and classified into 3 groups according to the residual MR severity at discharge: MR 0+/1+, 2+, and 3+/4+. The mortality and heart failure hospitalization rates at 1 year were 12.3% and 15.0%, respectively. Both MR and symptomatic improvement were sustained at 1 year with MR ≤2+ in 94.1% of patients and New York Heart Association functional class I/II in 95.0% of patients. Compared with residual MR 0+/1+ (20.4%) at discharge, both residual MR 2+ (30.2%; P < 0.001) and 3+/4+ (32.4%; P = 0.007) were associated with the higher incidence of death or heart failure hospitalization (adjusted hazard ratio [HR], 1.59; P < 0.001, and adjusted HR, 1.73; P = 0.008). New York Heart Association class III/IV at 1 year was more common in the MR 3+/4+ group (20.0%) than in the MR 0+/1+ (4.6%; P < 0.001) and MR 2+ (6.4%; P < 0.001) groups, and the proportion of New York Heart Association class I is significantly higher in the MR 1+ group (57.8%) than in the MR 2+ group (48.3%; P = 0.02). Conclusions The OCEAN-Mitral registry demonstrated favorable clinical outcomes and sustained MR reduction at 1 year in patients undergoing transcatheter edge-to-edge repair. Both residual MR 2+ and 3+/4+ after transcatheter edge-to-edge repair at discharge were associated with worse clinical outcomes compared with residual MR 0+/1+. Registration Information https://upload.umin.ac.jp. Identifier: UMIN000023653.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/methods , Risk Factors , Treatment Outcome , Cardiac Catheterization/adverse effects , Hemodynamics , Registries
SELECTION OF CITATIONS
SEARCH DETAIL
...