Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Jpn J Radiol ; 41(3): 258-265, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36350523

ABSTRACT

Pelvic fractures are common in cases of blunt trauma, which is strongly associated with mortality. Transcatheter arterial embolization is a fundamental treatment strategy for fatal arterial injuries caused by blunt pelvic trauma. However, vascular injuries due to blunt pelvic trauma can show various imaging findings other than arterial hemorrhage. We present a pictorial review of common and uncommon vascular injuries, including active arterial bleeding, pseudoaneurysm, arteriovenous fistula, arterial occlusion, vasospasm, and active venous bleeding. Knowledge of these vascular injuries can help clinicians select the appropriate therapeutic strategy and thus save lives.


Subject(s)
Arteriovenous Fistula , Embolization, Therapeutic , Vascular System Injuries , Wounds, Nonpenetrating , Humans , Vascular System Injuries/diagnostic imaging , Vascular System Injuries/etiology , Vascular System Injuries/therapy , Pelvis/diagnostic imaging , Hemorrhage/diagnostic imaging , Hemorrhage/etiology , Hemorrhage/therapy , Embolization, Therapeutic/methods , Arteriovenous Fistula/diagnostic imaging , Arteriovenous Fistula/etiology , Arteriovenous Fistula/therapy , Wounds, Nonpenetrating/complications , Wounds, Nonpenetrating/diagnostic imaging , Wounds, Nonpenetrating/therapy
2.
Minim Invasive Ther Allied Technol ; 31(7): 1066-1069, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35373696

ABSTRACT

Percutaneous transhepatic stent-graft placement usually requires more than a 12 F sheath, which has a higher potential risk of peritoneal hemorrhage. A case of postoperative portal vein hemorrhage after pancreaticoduodenectomy treated using a Viabahn VBX balloon expanding stent-graft is described in this report. The stent-graft was delivered using an 8 F sheath through a transhepatic approach and deployed from the superior mesenteric vein to the main portal vein. Hemostasis was achieved and graft patency was confirmed one year after the procedure.


Subject(s)
Portal Vein , Stents , Hemorrhage/etiology , Hemorrhage/surgery , Humans , Pancreaticoduodenectomy , Portal Vein/surgery , Treatment Outcome
3.
Jpn J Radiol ; 39(12): 1133-1140, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34216346

ABSTRACT

Resuscitative endovascular balloon occlusion of the aorta (REBOA) is performed in patients with hemorrhagic shock who develop massive subdiaphragmatic bleeding. This procedure enables rapid and less invasive aortic blockade compared to resuscitative thoracotomy and aortic cross-clamp procedures. However, the REBOA procedure is often blindly performed in the emergency department without fluoroscopy, and the appropriateness of the procedure may be evaluated on computed tomography (CT) after REBOA. Therefore, radiologists should be familiar with the imaging features of REBOA. We present a pictorial review of the radiological findings of REBOA along with a description of the procedure, its complications, and pitfalls.


Subject(s)
Balloon Occlusion , Endovascular Procedures , Shock, Hemorrhagic , Aorta/diagnostic imaging , Aorta/surgery , Humans , Resuscitation , Shock, Hemorrhagic/diagnostic imaging , Shock, Hemorrhagic/therapy , Tomography, X-Ray Computed
4.
PLoS One ; 14(12): e0224921, 2019.
Article in English | MEDLINE | ID: mdl-31790429

ABSTRACT

BACKGROUND: Since pancreatic steatosis is reported as a possible risk factor for pancreatic cancer, the development of a non-invasive method to quantify pancreatic steatosis is needed. Proton density fat fraction (PDFF) measurement is a magnetic resonance imaging (MRI) based method for quantitatively assessing the steatosis of a region of interest (ROI). Although it is commonly used for quantification of hepatic steatosis, pancreatic PDFF can greatly vary depending on the ROI's location because of the patchy nature of pancreatic fat accumulation. In this study, we attempted to quantify pancreatic steatosis by fat-water MRI with improved reproducibility. METHODS: Using the MRI images of 159 patients with nonalcoholic fatty liver disease, we attempted to calculate the average PDFF of whole pancreas. We set ROIs covering the entire area of the pancreas appearing in every slice and calculated the average PDFF from all the voxels included in the pancreas. We named this average value as whole-pancreatic PDFF and evaluated the reproducibility of the measured values. In addition to whole-pancreatic PDFF, we measured the average PDFF of the pancreatic head (head-PDFF) and that of the pancreatic body plus tail separately and analyzed their correlation with the clinical characteristics of the patients. RESULTS: The mean inter-examiner coefficient of variation of the whole-pancreatic PDFF was 11.39%. The whole-pancreatic PDFF was correlated with age (p = 0.039), body mass index (p = 0.0093) and presence/absence of diabetes (p = 0.0055). The serum level of low-density lipoprotein cholesterol was inversely correlated with the head-PDFF. CONCLUSION: We developed a new measurement method of the pancreatic PDFF with greater reproducibility. Using this method, we characterized pancreatic steatosis in detail. This novel measurement method allows accurate estimation of the severity of pancreatic steatosis and is therefore useful for the detailed characterization of pancreatic steatosis.


Subject(s)
Adipose Tissue/diagnostic imaging , Adipose Tissue/pathology , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Non-alcoholic Fatty Liver Disease/diagnostic imaging , Pancreas/pathology , Water/metabolism , Aged , Female , Humans , Male , Middle Aged , Non-alcoholic Fatty Liver Disease/pathology , Pancreas/diagnostic imaging , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...