Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Cardiol ; 386: 17-23, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37201615

ABSTRACT

BACKGROUND: Echocardiography-based transvalvular mean pressure gradient (ECHO-mPG) used to assess the forward valve function and structural valve deterioration could overestimate the true pressure gradient. This study evaluated the discrepancy between invasive and ECHO-mPG after transcatheter aortic valve implantation (TAVI) with respective valve type and size, its impact on a device success criterion, and predictors of a pressure discrepancy. METHODS: We analyzed 645 patients registered in a multicenter TAVI registry (balloon-expandable valve [BEV]: 500; self-expandable valve [SEV]: 145). The invasive transvalvular mPG was measured after valve implantation using two Pigtail catheters (CATH-mPG), while the ECHO-mPG was measured within 48 h after TAVI. Pressure recovery (PR) was calculated using the following formula: ECHO-mPG × effective orifice area (EOA)/ascending aortic area (AoA) × (1 - EOA/AoA). RESULTS: ECHO-mPG was weakly correlated with (r = 0.29, p < 0.0001), and consistently overestimated CATH-mPG in both BEV and SEV, and respective valve sizes. The magnitude of the discrepancy was larger for BEV than SEV (p < 0.001) and smaller valves (p < 0.001). After the correction of PR using the above formula, the pressure discrepancy remained for BEV (p < 0.001) but not SEV (p = 0.10). The proportion of patients with an ECHO-mPG > 20 mmHg decreased from 7.0% to 1.6% after correction (p < 0.0001). Among the baseline and procedural variables, post-procedural ejection fraction, BEV versus SEV, and smaller valves were associated with a larger discrepancy in mPG. CONCLUSIONS: ECHO-mPG could be overestimated after TAVI, especially in patients with a smaller BEV. A higher ejection fraction, BEV, and smaller valves were predictors of a pressure discrepancy between CATH- and ECHO-mPG.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography , Registries , Treatment Outcome , Prosthesis Design
2.
J Alzheimers Dis ; 58(2): 349-354, 2017.
Article in English | MEDLINE | ID: mdl-28453490

ABSTRACT

To elucidate an involvement of amyloid dysmetabolism in the pathophysiology of depression, we investigated associations of plasma amyloid-ß (Aß) levels with Alzheimer's disease-related changes in neuroimaging and cognitive dysfunction in patients with late-life depression. Higher plasma Aß40, but not Aß42 nor Aß40/Aß42 ratio, was associated with higher degree of parahippocampal atrophy and lower verbal fluency performance. Indeed, high plasma Aß40 predicted poor cognitive prognosis of depressed patients with mild cognitive impairment. As an anti-depressive treatment, electroconvulsive therapy (ECT) resulted in a marginally significant reduction of plasma Aß40 compared to pharmacotherapy alone, suggesting protective effects of ECT against amyloid dysmetabolism.


Subject(s)
Amyloid beta-Peptides/blood , Depressive Disorder/blood , Depressive Disorder/therapy , Peptide Fragments/blood , Aged , Aged, 80 and over , Antidepressive Agents/therapeutic use , Cognitive Dysfunction/etiology , Depressive Disorder/diagnostic imaging , Electroconvulsive Therapy/methods , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Neuropsychological Tests , Psychiatric Status Rating Scales
SELECTION OF CITATIONS
SEARCH DETAIL
...