Int J Part Ther ; 11: 100011, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38757079

ABSTRACT

Purpose: We performed computed tomography (CT)-stopping power ratio (SPR) calibration in a carbon-ion therapy facility and evaluated SPR estimation accuracy. Materials and Methods: A polybinary tissue model method was used for the calibration of CT numbers and SPR. As a verification by dose calculation, we created a virtual phantom to which the CT-SPR calibration table was applied. Then, SPR was calculated from the change in the range of the treatment planning beam when changing to 19 different CT numbers, and the accuracy of the treatment planning system (TPS) calculation of SPR values from the CT-SPR calibration table was validated. As a verification by measurement, 5 materials (water, milk, olive oil, ethanol, 40% K2HPO4) were placed in a container, and the SPR was obtained by measurement from the change in the range of the beam that passed through the materials. Results: The results of the dose calculations of the TPS showed that the results agreed within 1% for the lower CT numbers up to 1000 HU, but there was a difference of 3.0% in the higher CT number volume. The difference between the SPR calculated by TPS and the SPR caused by the difference in the energy of the incident particles agreed within 0.51%. The accuracy of SPR estimation was measured, and the error was within 2% for all materials tested. Conclusion: These results indicate that the SPR estimation errors are within the range of errors that can be expected in particle therapy. From commissioning and verification results, the CT-SPR calibration table obtained during this commissioning process is clinically applicable.

2.
J Appl Clin Med Phys ; 24(5): e13987, 2023 May.
Article in English | MEDLINE | ID: mdl-37018016

ABSTRACT

The errors on the stopping power ratio (SPR) of mouthpiece samples from ERKODENT were evaluated. Erkoflex and Erkoloc-pro from ERKODENT and samples that combined Erkoflex and Erkoloc-pro were computed tomography (CT)-scanned using head and neck (HN) protocol at the East Japan Heavy Ion Center (EJHIC), and the values were averaged to obtain the CT number. The integral depth dose of the Bragg curve with and without these samples was measured for 292.1, 180.9, and 118.8 MeV/u of the carbon-ion pencil beam using an ionization chamber with concentric electrodes at the horizontal port of the EJHIC. The average value of the water equivalent length (WEL) of each sample was obtained from the difference between the range of the Bragg curve and the thickness of the sample. To calculate the difference between the theoretical and measured values, the theoretical CT number and SPR value of the sample were calculated using the stoichiometric calibration method. Compared with the Hounsfield unit (HU)-SPR calibration curve used at the EJHIC, the SPR error on each measured and theoretical value was calculated. The WEL value of the mouthpiece sample had an error of approximately 3.5% in the HU-SPR calibration curve. From this error, it was evaluated that for a mouthpiece with a thickness of 10 mm, a beam range error of approximately 0.4 mm can occur, and for a mouthpiece with a thickness of 30 mm, a beam range error of approximately 1 mm can occur. For a beam passing through the mouthpiece in HN treatment, it would be practical to consider a mouthpiece margin of 1 mm to avoid beam range errors if ions pass through the mouthpiece.


Subject(s)
Heavy Ion Radiotherapy , Proton Therapy , Humans , Phantoms, Imaging , Polyethylenes , Polyvinyls , Water , Radiotherapy Planning, Computer-Assisted/methods