Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
1.
Eur J Radiol ; 177: 111579, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38897053

ABSTRACT

PURPOSE: Quantitative MRI techniques such as T2 mapping are useful in comprehensive evaluation of various pathologies of the knee joint yet require separate scans to conventional morphological measurements and long acquisition times. The recently introduced 3D MIXTURE (Multi-Interleaved X-prepared Turbo-Spin Echo with Intuitive Relaxometry) technique can obtain simultaneous morphologic and quantitative information of the knee joint. To compare MIXTURE with conventional methods and to identify differences in morphological and quantitative information. METHODS: Phantom studies were conducted, and in vivo human scans were performed (20 patients) presented with knee arthralgia. MIXTURE is based on 3D TSE without and with T2 preparation modules in an interleaved manner for both morphology with PDW and fat suppressed T2W imaging as well as quantitative T2 mapping within one single scan. Image quality and lesion depiction were visually assessed and compared between MIXTURE and conventional 2D TSE by two experienced radiologists. Contrast-to-noise ratio was used to assess the adjacent tissue contrast in a quantitative way for both obtained PDW and fat suppressed T2W images. Quantitative T2 values were measured in phantom and from in vivo knee cartilage. RESULTS: The overall diagnostic confidence and contrast-to-noise ratio were deemed comparable between MIXTURE and 2D TSE. While the chosen T2 preparation modules for MIXTURE rendered consistent T2 values comparing to the current standard, measured cartilage T2 values ranged from 26.1 to 50.7 ms, with significant difference between the lesion and normal areas (p < 0.05). CONCLUSIONS: MIXTURE can help to provide high-resolution information for both anatomical and pathological assessment.


Subject(s)
Imaging, Three-Dimensional , Knee Joint , Magnetic Resonance Imaging , Phantoms, Imaging , Humans , Male , Female , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods , Middle Aged , Knee Joint/diagnostic imaging , Knee Joint/pathology , Adult , Aged , Image Interpretation, Computer-Assisted/methods , Arthralgia/diagnostic imaging , Image Enhancement/methods , Reproducibility of Results
2.
J Radiol Prot ; 44(2)2024 May 17.
Article in English | MEDLINE | ID: mdl-38722292

ABSTRACT

According to International Commission of Radiological Protection, the equivalent dose limit for the eye lens for occupational exposure is recommended to be 20 mSv yr-1, averaged over 5 years, with no single year above 50 mSv. Some studies reported the measurement of assistant's lens exposure in diagnostic computed tomography (CT) examinations, but further investigation is still required in the association between the lens dose for assistants and various dose parameters. Therefore, we measured the assistant's lens exposure using small optically stimulated luminescence dosimeters. The type of occupation, type of assistance, total scan time, total mAs, total scan length, and dose-length product (DLP) were recorded and analyzed in association with air kerma at the lens position. The assistance was classified into four types: 'assisted ventilation,' 'head holding,' 'body holding,' and 'raising patient's arm.' The air kerma of lens position was not significantly different for each assistance type (p< 0.05, Kruskal-Wallis test). Further, the lens doses for assistants correlated with DLP, but with various strengths of correlation with the assistance type and were influenced by the distance from the CT gantry. In conclusion, lens dose during assistance and DLP demonstrated the strongest correlation. 'Raising patient's arm' and 'head holding' exhibited stronger correlations, which required less table movement during the CT scan than 'assisted ventilation' and 'body holding'.


Subject(s)
Lens, Crystalline , Occupational Exposure , Radiation Dosage , Tomography, X-Ray Computed , Lens, Crystalline/radiation effects , Humans , Occupational Exposure/analysis , Radiation Protection , Radiation Exposure/analysis
4.
Sci Rep ; 13(1): 2266, 2023 02 08.
Article in English | MEDLINE | ID: mdl-36755154

ABSTRACT

There is no preoperative imaging accurately diagnose malignancy of gastrointestinal stromal tumor (GIST). To evaluate the usefulness of preoperative [18F]2-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in the malignant diagnosis and prognostic analysis of GIST. Eighty-nine consecutive patients with GIST who underwent curative surgery were reviewed retrospectively. PET scan was performed within 2-3 weeks before surgery and maximum standardized uptake values (SUVmax) were assessed for GIST. The relationship between prognostic factors and prognosis of GIST and SUVmax were evaluated. Tumor size, mitotic count, and Ki-67 index showed significant positive correlations with the SUVmax. When the cutoff value was set as SUVmax 5.68, the accuracy was 86.5% for the high-risk group, 76.4% for the recurrence group, and 73.0% for the death group. The group with SUVmax ≥ 5.68 demonstrated a significantly lower 10-year relapse-free survival than the group with SUVmax < 5.68 (55.2% vs. 98.2%, P < 0.001), while the group with SUVmax ≥ 5.68 demonstrated a significantly lower 10-year overall survival than the group with SUVmax < 5.68 (68.0% vs. 97.6%, P < 0.001). In GISTs, FDG-PET is a very useful imaging marker for the diagnosis of malignant GISTs, such as those in high-risk and poor-prognosis groups.


Subject(s)
Fluorodeoxyglucose F18 , Gastrointestinal Stromal Tumors , Humans , Prognosis , Gastrointestinal Stromal Tumors/diagnostic imaging , Gastrointestinal Stromal Tumors/surgery , Gastrointestinal Stromal Tumors/pathology , Radiopharmaceuticals , Retrospective Studies , Tomography, X-Ray Computed , Neoplasm Recurrence, Local/diagnostic imaging , Positron-Emission Tomography , Positron Emission Tomography Computed Tomography
6.
Radiol Phys Technol ; 16(1): 39-47, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36515865

ABSTRACT

The effective focal spot size of x-ray tubes is one of the major factors that substantially affect the resultant x-ray images, and it is known to be dependent on the x-ray exposure setting used. This study aims to evaluate the relationship between the effective focal spot size and the tube current and voltage and assess its reproducibility among several x-ray tubes. The evaluation was performed using edge response analysis, in which a 1-mm thick tungsten edge was projected onto a flat panel detector with a magnification factor of 2. The edge image was then differentiated to obtain the line spread function, followed by a detector blur-removing process through Fourier analysis to obtain the true focus profile. The resultant focal spot size increased as the tube current increased, whereas it decreased as the tube voltage increased, as expected. The rate of change was similar along the width and the length directions, while the small focus changed more significantly than the large focus. The reproducibility among four x-ray tubes of the same model was excellent as the maximum variation < 20%. In conclusion, the edge response method can provide useful information on the x-ray focal spot relationship with the x-ray exposure settings used, as well as its reproducibility among several x-ray tubes.


Subject(s)
Radiographic Image Enhancement , Tomography, X-Ray Computed , X-Rays , Reproducibility of Results , Radiography , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods
7.
J Radiol Prot ; 42(2)2022 06 24.
Article in English | MEDLINE | ID: mdl-35705067

ABSTRACT

In computed tomography (CT) examinations, the usefulness of protective glasses for reducing lens exposure to assistants has been reported. The present study aimed to compare the dose reduction effect for assistants with lead-acrylic shields and protective glasses (0.07 mm Pb, 0.5 mm Pb) during CT examination. The air dose distribution in a CT examination room with and without a lead-acrylic shield was compared. It was found that the amount of scattered radiation was significantly reduced by installing a lead-acrylic shield at the CT gantry aperture. Moreover, the reduction rate of air kerma at the assistant's lens was higher using the lead acrylic shield than with the protective glasses-95.7% during head holding and 76.1% during assisted ventilation.


Subject(s)
Lens, Crystalline , Radiation Protection , Lead , Phantoms, Imaging , Radiation Dosage , Radiation Protection/methods , Tomography, X-Ray Computed , X-Rays
8.
Cureus ; 13(10): e18428, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34733598

ABSTRACT

Introduction Lumbar degenerative spondylolisthesis (DS) is one of the most common causes of low back pain. The lumbar muscles, such as the psoas major (PM), erector spinae (ES), and multifidus (MF) muscles, play an important role in the stability and functional movement of the lumbar spine. The quantities and qualities of these muscles may be related to the occurrence of DS and lumbopelvic parameters, such as lumbar lordosis (LL) and sacral slope (SS). However,the influence of lumbar muscles on DS and lumbopelvic alignment is not well understood. Methods Patients with L4 DS (DS group, n=25) and without DS (non-DS group, n=25) were included. Using sagittal reconstructed CT images of patients who visited our hospital for reasons other than low back disorders, LL, upper lumbar lordosis ([ULL] L1-L4), lower lumbar lordosis ([LLL] L4-S1), and SS were examined. To evaluate the quantity and quality of lumbar muscles, the gross cross-sectional area (GCSA), functional cross-sectional area (FCSA), and fat infiltration (FI) of the PM, ES, and MF muscles were measured by CT images. The lumbopelvic parameters, FCSA, GCSA, and FI of lumbar muscles were compared between the two groups. Then, each lumbar muscle parameter was analyzed for correlation with DS and lumbopelvic parameters. Results DS patients displayed significantly greater ULL and lower FI of the PM and ES muscles than non-DS patients (p=0.0078, 0.031, and 0.010, respectively). The FI of the ES muscle was significantly correlated with the presence of DS (p=0.010). The FCSA of the ES and MF muscles and the GCSA of the MF muscle showed a significant correlation with LL and SS in the non-DS group (p<0.05), but not in the DS group.. Conclusion ULL was greater in L4 DS patients, possibly related to the better quality of the ES muscle. All DS patients showed mild (grade I) spondylolisthesis, suggesting the possibility that lumbar muscle quality is better in patients with mild DS than in those without DS. The ES and MF muscles may play an important role in maintaining the lumbar lordotic angle in non-DS patients but not in DS patients.

10.
Spine Surg Relat Res ; 5(4): 278-283, 2021.
Article in English | MEDLINE | ID: mdl-34435152

ABSTRACT

INTRODUCTION: Previous studies have reported differences in lumbopelvic alignment between standing and supine positions. Computed tomography (CT) images taken in the supine position are often used for clinical studies in addition to standing radiographs, although not frequently. Our study aims to clarify normative values of CT-evaluated lumbopelvic parameters and the characteristics of age- and gender-related lumbopelvic alignment in the supine position. METHODS: Patients undergoing CT scans of abdominal or lumbar regions for reasons other than low back disorders were included (n=581). Sagittal multiplanar reconstruction CT images were obtained, and lumbar lordosis (LL), L5-S1 angle, and sacral slope (SS) were measured. Mean values of the parameters in patients aged 59 years and under, 60-69, 70-79, and 80 and over, and in males and females, were calculated. Age- and gender-related differences in these parameters were statistically analyzed. RESULTS: Among the four age groups, patients 80 years and over showed significantly lower LL and SS than patients aged 70-79. Females 80 years and over showed significantly lower LL and SS than all other age groups, but those in males did not. The comparison between males and females showed no significant differences in LL and SS; however, the L5-S1 angle was significantly higher in males than in females. In patients 80 years and over, females showed significantly lower LL and SS than in males. CONCLUSIONS: This study provides normative CT-evaluated lumbopelvic parameters, such as LL, L5-S1 angle, and SS, which will be utilized for comparisons in future studies. The present study first revealed that pelvic retroversion and lumbar kyphosis occur in elderly females in the supine position, which raised a possibility that age-related decrease of LL and SS in females occurs at an older age in the supine position than in the standing position.

11.
World Neurosurg ; 147: e524-e532, 2021 03.
Article in English | MEDLINE | ID: mdl-33385597

ABSTRACT

BACKGROUND: To elucidate the influence of spondylolysis on age-related lumbar degenerative changes, age-specific lumbopelvic alignment in patients with or without spondylolysis was examined. METHODS: Sagittal reconstructed computed tomography images of the lumbar spine in consecutive patients (n = 581) undergoing computed tomography scans of abdominal or lumbar regions for reasons other than low back disorders were obtained. Lumbar lordosis (LL), L5-S1 angle, and sacral slope (SS) were measured. Lumbopelvic parameters in patients with or without spondylolysis were evaluated in 3 age groups (<50, 50-69, and ≥70). The influence of bilateral L5 spondylolysis (L5-lysis) and L5 vertebral slip on each lumbopelvic parameter, as well as correlation between cross-sectional area (CSA) of paraspinal muscles and the degree of vertebral slip, were examined by multiple regression analysis. RESULTS: Patients with bilateral spondylolysis showed greater LL and SS than patients without spondylolysis. When analyzing the influence of L5-lysis, only elderly patients (≥70) with L5-lysis showed significantly greater LL and SS than nonspondylolysis (nonlysis) patients. L5-lysis patients more frequently showed L5 vertebral slip than nonlysis patients, and a smaller L5-S1 angle was observed when L5 vertebral slip accompanied L5-lysis. The degree of vertebral slip was significantly correlated with CSA of psoas muscles, but not with CSA of paraspinal extensor muscles. CONCLUSIONS: When patients have L5-lysis, lumbar lordosis and pelvic anteversion occurred age dependently. In elderly patients with L5-lysis, L5 vertebral slip with decrease of the L5-S1 angle occurs frequently. The progression of vertebral slip was correlated with atrophy of psoas muscles, but not that of paraspinal extensor muscles.


Subject(s)
Age Factors , Aging , Lumbar Vertebrae/pathology , Spondylolysis/surgery , Adult , Aged , Humans , Lordosis/complications , Lordosis/surgery , Lumbar Vertebrae/surgery , Lumbosacral Region/pathology , Lumbosacral Region/surgery , Male , Middle Aged , Paraspinal Muscles/surgery , Spondylolysis/complications
12.
Article in Japanese | MEDLINE | ID: mdl-32435031

ABSTRACT

We report on the construction of a system for managing prior information and injection condition used for contrast enhance CT examination using radiology information system (RIS). Contrast dose administration system using the RIS was possible to retrospectively investigate optimal injection conditions from the database. As the prior information, we designed the patient's profile information of the hospital information system (HIS) to reflect the patient's height, weight, and kidney function (eGFR, Cre), which is necessary information for contrast enhance CT examination, in the RIS. By adding E-Box (DICOM Gateway) to the injector, it became possible to reflect the amount of contrast agent used in patients and injection conditions at contrast enhance CT examination. The contrast agent use information is transmitted to RIS by using modality performed procedure step (MPPS). Database of injection condition at contrast enhance CT examination using the RIS, to determine the optimal injection conditions retrospectively. By utilizing the massive amount of clinical information stored in the RIS, the amount of contrast agent and injection condition at contrast enhance CT examination could be optimized. Reproducibility of the contrast effect can be secured. In the CE, evidence system linked with RIS, when considering the reproducibility at follow-up observation and comparative diagnosis in clinical practice, the contrast effect could be made constant. Contrast dose administration system using the RIS was useful.


Subject(s)
Hospital Information Systems , Radiology Information Systems , Humans , Reproducibility of Results , Retrospective Studies
13.
Sci Rep ; 10(1): 6739, 2020 04 21.
Article in English | MEDLINE | ID: mdl-32317683

ABSTRACT

Lumbar spondylolysis generally occurs in adolescent athletes. Bony union can be expected with conservative treatment, however, the fracture does not heal in some cases. When the fracture becomes a pseudoarthrosis, spondylolysis patients have the potential to develop isthmic spondylolisthesis. A cross-sectional study was performed to determine the incidence of spondylolysis and spondylolisthesis, and to elucidate when and how often spondylolisthesis occurs in patients with or without spondylolysis. Patients undergoing computed tomography (CT) scans of abdominal or lumbar regions for reasons other than low back pain were included (n = 580). Reconstruction CT images were obtained, and the prevalence of spondylolysis and spondylolisthesis were evaluated. Of the 580 patients, 37 patients (6.4%) had spondylolysis. Of these 37 patients, 19 patients (51.4%) showed spondylolisthesis, whereas only 7.4% of non-spondylolysis patients showed spondylolisthesis (p < 0.05). When excluding unilateral spondylolysis, 90% (18/20) of spondylolysis patients aged ≥60 years-old showed spondylolisthesis. None of the patients with isthmic spondylolisthesis had received fusion surgery, suggesting that most of these patients didn't have a severe disability requiring surgical treatment. Our results showed that the majority of bilateral spondylolysis patients aged ≥60 years-old show spondylolisthesis, and suggest that spondylolisthesis occurs very frequently and may develop at a younger age when spondylolysis exists.


Subject(s)
Lumbar Vertebrae/pathology , Lumbosacral Region/pathology , Spondylolisthesis/epidemiology , Spondylolysis/epidemiology , Adolescent , Adult , Aged , Aged, 80 and over , Athletes , Child , Cross-Sectional Studies , Disease Progression , Female , Humans , Japan/epidemiology , Lumbar Vertebrae/diagnostic imaging , Lumbosacral Region/diagnostic imaging , Male , Middle Aged , Prevalence , Spondylolisthesis/diagnostic imaging , Spondylolisthesis/pathology , Spondylolysis/diagnostic imaging , Spondylolysis/pathology , Tomography, X-Ray Computed
14.
Esophagus ; 17(3): 239-249, 2020 07.
Article in English | MEDLINE | ID: mdl-31820208

ABSTRACT

BACKGROUND: Although diffusion-weighted magnetic resonance imaging (DWI) for detecting lymph node (LN) metastasis is reported to be a successful modality for primary malignant tumors, there are few studies relating to esophageal cancer. This study aimed to clarify the diagnostic performance of DWI for assessing LN metastasis compared with positron emission tomography (PET) in patients with esophageal squamous cell cancer (eSCC). METHODS: Seventy-six patients with histologically proven eSCC who underwent curative esophagectomy without neoadjuvant treatment were reviewed retrospectively. Harvested LNs were divided into 1229 node stations with 94 metastases. Diagnostic abilities and prognostic significance were compared. RESULTS: In a station-by-station evaluation, the sensitivity was higher in DWI than PET (67% vs. 32%, P < 0.001). DWI showed more than 80% sensitivity for middle- and large-sized cancer nests and large area of cancer nests. The DWI-N0 group had a better 5-year relapse-free survival rate than the DWI-N+ group (78.5% vs. 34.2%, P < 0.001), as did the PET-N0 group. DWI-N status was an independent prognostic factor (hazard ratio [HR], 2.642; P = 0.048), as was PET-N status (HR 2.481; P = 0.033). CONCLUSIONS: DWI, which depends on cancer cell volume followed by elevated intranodal density, is a non-invasive modality and showed higher sensitivity than PET. It has clinical impact in predicting postoperative survival for patients with eSCC alongside its diagnostic ability and has significant performance in clinical practice.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Esophageal Neoplasms/pathology , Esophageal Squamous Cell Carcinoma/secondary , Lymphatic Metastasis/diagnostic imaging , Positron-Emission Tomography/methods , Adult , Aged , Aged, 80 and over , Cell Count/statistics & numerical data , Disease-Free Survival , Esophageal Squamous Cell Carcinoma/diagnosis , Esophageal Squamous Cell Carcinoma/mortality , Esophageal Squamous Cell Carcinoma/surgery , Esophagectomy/methods , Female , Humans , Lymph Nodes/pathology , Male , Middle Aged , Neoplasm Staging/methods , Postoperative Period , Prognosis , Retrospective Studies , Sensitivity and Specificity , Tumor Burden/physiology
15.
Radiol Phys Technol ; 12(4): 393-400, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31691889

ABSTRACT

Recently, there has been a significant amount of interest in studying the importance of radiation doses to the eye lens during endoscopic retrograde cholangiopancreatography (ERCP). A study that focused on measuring the scattered radiation using an ionization chamber survey meter reported that a lead curtain was useful in reducing the scattered radiation. The over-couch X-ray tube system tends to deliver higher doses to the head and neck of the staff involved in the procedure than the under-couch X-ray tube position. In this study, a small optically stimulated luminescence (OSL) dosimeter called the nanoDot was used to evaluate and measure the amount of radiation; this dosimeter was developed by Landauer Ltd. and was specifically designed for point measurements. There are numerous studies that have reported the usefulness of personal OSL dosimeters other than the nanoDot to measure scattered radiation. Here, we evaluated the amount of scattered radiation, along with the degree of reduction achieved with the use of a protective curtain, while employing a personal OSL dosimeter and nanoDot. When the scattered radiation dose was measured using the nanoDot, the maximum recorded value without a protective curtain was 0.363 mGy and that with a protective curtain was 0.026 mGy, both at the height of 100 cm. The maximum reduction rate of scattered radiation while using a protective curtain was approximately 93% and 97% at 100 cm and 150 cm, respectively. The measured values recorded using both personal OSL dosimeters and nanoDot machine were strongly correlated.


Subject(s)
Fluoroscopy/instrumentation , Optically Stimulated Luminescence Dosimetry , Scattering, Radiation , Humans , Occupational Exposure/prevention & control , Radiation Dosage , Radiation Protection/instrumentation
16.
Article in Japanese | MEDLINE | ID: mdl-31105104

Subject(s)
Leadership , Science
17.
Article in Japanese | MEDLINE | ID: mdl-30033964

ABSTRACT

A survey on recognition, utilization, and evaluation for diagnostic reference levels (DRLs) after establishing Japan DRLs 2015 in the field of X-ray computed tomography (CT) was conducted for members of Japanese Society of Radiological Technology using web-based questionnaire system. The survey consisted of provincial branches to which respondents belong, their occupation, years of professional experience, years of experience in X-ray CT section, recognition of DRLs, and utilization and evaluation of DRLs in the field of X-ray CT section. Each survey item had one to eight questions. A total of 369 members completed the questionnaire. Among them, 295 out of 369 (79.9%) members knew that DRLs were released in Japan. After establishing the DRLs, 226 of 330 (68.5%) and 123 of 319 (38.6%) members investigated the doses used for adult and pediatric CT at their facilities, respectively. Although 345 of 369 (93.5%) members answered that DRLs are necessary for the field of X-ray CT, only 142 of 369 (38.5%) members thought that the established DRLs are enough to use in the field of X-ray CT. The survey has clarified the current status of recognition, utilization, and evaluation for DRLs in the field of X-ray CT after establishing the DRLs in Japan.


Subject(s)
Tomography, X-Ray Computed , Adult , Child , Humans , Japan , Radiation Dosage , Reference Values , Surveys and Questionnaires
18.
Magn Reson Imaging ; 49: 78-85, 2018 06.
Article in English | MEDLINE | ID: mdl-29408676

ABSTRACT

PURPOSE: Diffusion tensor imaging (DTI) based on a single-shot echo planer imaging (EPI-DTI) is an established method that has been used for evaluation of lumbar nerve disorders in previous studies, but EPI-DTI has problems such as a long acquisition time, due to a lot of axial slices, and geometric distortion. To solve these problems, we attempted to apply DTI based on a single-shot turbo spin echo (TSE-DTI) with direct coronal acquisition. Our purpose in this study was to investigate whether TSE-DTI may be more useful for evaluation of lumbar nerve disorders than EPI-DTI. MATERIALS AND METHODS: First, lumbar nerve roots of five healthy volunteers were evaluated for optimization of imaging parameters with TSE-DTI including b-values and the number of motion proving gradient (MPG) directions. Subsequently, optimized TSE-DTI was quantitatively compared with conventional EPI-DTI by using fractional anisotropy (FA) values and visual scores in subjective visual evaluation of tractography. Lumbar nerve roots of six patients, who had unilateral neurologic symptoms in one leg, were evaluated by the optimized TSE-DTI. RESULTS: TSE-DTI with b-value of 400 s/mm2 and 32 diffusion-directions could reduce the image distortion compared with EPI-DTI, and showed that the average FA values on the symptomatic side for six patients were significantly lower than those on the non-symptomatic side (P < 0.05). CONCLUSION: Tractography with TSE-DTI might show damaged areas of lumbar nerve roots without severe image distortion. TSE-DTI might improve the reproducibility in measurements of FA values for quantification of a nerve disorder, and would become a useful tool for diagnosis of low back pain.


Subject(s)
Diffusion Tensor Imaging/methods , Spinal Nerve Roots/physiology , Aged , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Female , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/innervation , Male , Middle Aged , Motion , Reference Values , Reproducibility of Results , Spinal Nerve Roots/diagnostic imaging
19.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 73(12): 1252-1257, 2017.
Article in Japanese | MEDLINE | ID: mdl-29269621

ABSTRACT

Currently, non-contrast angiography using the balanced steady-state free precession (b-SSFP) method, which uses a short scan time imaging method, has been reported as an alternative to lower-extremity MRA's conventional method. We investigated a new imaging method using balanced SSFP. This method uses a sequence of spectral attenuated inversion recovery (SPAIR) pulse for fat suppression, selective saturation pre-pulse for imaging range of background signal suppression, and rest slab on the downstream side of the imaging range for vein signal suppression. In the examination, we changed dummy pulse (0, 5, 10), saturation delay time (150 ms, 225 ms, 300 ms), and acquisition time (200 ms, 250 ms, 300 ms). For physical evaluation, we used the ROI method and for visual evaluation, we used the Scheffe's method. CR was the best and the visual evaluation was also good 10 for dummy pulse, a saturation delay time of 150 ms, and an acquisition time of 200 ms. Balanced SSFP with saturation recovery has the potential to shorten scanning times. Balanced SSFP with saturation recovery is useful for lower-extremity MRA.


Subject(s)
Lower Extremity/diagnostic imaging , Magnetic Resonance Angiography/methods , Adult , Humans , Male , Young Adult
20.
Intern Med ; 56(14): 1781-1790, 2017.
Article in English | MEDLINE | ID: mdl-28717072

ABSTRACT

Objective Osteoporosis, which is now recognized as a major comorbidity of chronic obstructive pulmonary disease (COPD), must be diagnosed by appropriate methods. The aims of this study were to clarify the relationships between bone mineral density (BMD) and COPD-related clinical variables and to explore the association of BMD with the updated Global Initiative for Chronic Obstructive Lung Disease (GOLD) classification in men. Methods We enrolled 50 Japanese men with clinically stable COPD who underwent dual-energy X-ray absorptiometry (DEXA), pulmonary function testing, and computerized tomography (CT) and who had completed a questionnaire (COPD assessment test [CAT]). We determined the association between the T-score and other tested parameters and compared the BMD of patients in each GOLD category. Results Twenty-three of the 50 patients (46.0%) were diagnosed with osteopenia, and 7 (14.0%) were diagnosed with osteoporosis. The BMD findings were significantly correlated with the CAT score, forced expiratory volume in 1 second percentage predicted (FEV1% predicted), low attenuation volume percentage (LAV%), and percentage of cross-sectional area of small pulmonary vessels (%CSA) on CT images. Notably, the median T-score of the GOLD category D participants was significantly lower than that of the participants in each of the other categories (A [-0.98], B [-1.06], C [-1.05], and D [-2.19], p<0.05). Conclusion Reduced BMD was associated with airflow limitation, extent of radiographic findings, and a poor quality of life (QOL) in patients with COPD. The BMD of GOLD category D patients was the lowest of all of the patients evaluated, and category D patients may benefit from active intervention for osteoporosis.


Subject(s)
Bone Density , Osteoporosis/etiology , Osteoporosis/physiopathology , Pulmonary Disease, Chronic Obstructive/complications , Pulmonary Disease, Chronic Obstructive/physiopathology , Absorptiometry, Photon , Aged , Asian People , Cross-Sectional Studies , Humans , Male , Middle Aged , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...