Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 64(21): 215002, 2019 10 23.
Article in English | MEDLINE | ID: mdl-31470440

ABSTRACT

In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energy (DE) DM. Our mathematical framework unifies and generalizes existing approaches. We compared mathematical predictions directly with empirical measurements of the anatomic noise power spectrum of the CIRS BR3D structured breast phantom using two clinical mammography systems and four beam qualities. Our simulation and experimental results showed agreement with mathematical predictions. As a demonstration of utility, we used our mathematical framework in a theoretical spectral optimization of DM for the task of detecting breast masses. Our theoretical optimization showed that the optimal tube voltage for DM may be higher than that based on predictions that do not account for anatomic noise, in agreement with recent theoretical findings. Additionally, our theoretical optimization predicts that filtering tungsten-anode x-ray spectra with rhodium has little influence on lesion detectability, in contrast with previous findings. The mathematical methods validated in this work can be incorporated easily into cascaded systems analysis of breast imaging systems and will be useful when optimizating novel techniques for x-ray-based imaging of the breast.


Subject(s)
Mammography/methods , Radiographic Image Enhancement/methods , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Female , Humans , Mammography/standards , Phantoms, Imaging , Radiographic Image Enhancement/standards , Signal-To-Noise Ratio , Systems Analysis
2.
J Appl Clin Med Phys ; 16(6): 501-507, 2015 11 08.
Article in English | MEDLINE | ID: mdl-26699559

ABSTRACT

This technical note demonstrates computed tomography (CT) radiation profile measurement using computed radiography (CR) imaging plate raw data showing it is possible to perform the CT collimation width measurement using a single scan without saturating the imaging plate. Previously described methods require careful adjustments to the CR reader settings in order to avoid signal clipping in the CR processed image. CT radiation profile measurements were taken as part of routine quality control on 14 CT scanners from four vendors. CR cassettes were placed on the CT scanner bed, raised to isocenter, and leveled. Axial scans were taken at all available collimations, advancing the cassette for each scan. The CR plates were processed and raw CR data were analyzed using MATLAB scripts to measure collimation widths. The raw data approach was compared with previously established methodology. The quality control analysis scripts are released as open source using creative commons licensing. A log-linear relationship was found between raw pixel value and air kerma, and raw data collimation width measurements were in agreement with CR-processed, bit-reduced data, using previously described methodology. The raw data approach, with intrinsically wider dynamic range, allows improved measurement flexibility and precision. As a result, we demonstrate a methodology for CT collimation width measurements using a single CT scan and without the need for CR scanning parameter adjustments which is more convenient for routine quality control work.


Subject(s)
Tomography Scanners, X-Ray Computed/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Humans , Quality Control , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Software , Tomography Scanners, X-Ray Computed/standards , Tomography, X-Ray Computed/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...