1.
Sensors (Basel) ; 21(9)2021 Apr 28.
Article in English | MEDLINE | ID: mdl-33925157

ABSTRACT

We report the development of a new type of space lidar specifically designed for missions to small planetary bodies for both topographic mapping and support of sample collection or landing. The instrument is designed to have a wide dynamic range with several operation modes for different mission phases. The laser transmitter consists of a fiber laser that is intensity modulated with a return-to-zero pseudo-noise (RZPN) code. The receiver detects the coded pulse-train by correlating the detected signal with the RZPN kernel. Unlike regular pseudo noise (PN) lidars, the RZPN kernel is set to zero outside laser firing windows, which removes most of the background noise over the receiver integration time. This technique enables the use of low peak-power but high pulse-rate lasers, such as fiber lasers, for long-distance ranging without aliasing. The laser power and the internal gain of the detector can both be adjusted to give a wide measurement dynamic range. The laser modulation code pattern can also be reconfigured in orbit to optimize measurements to different measurement environments. The receiver uses a multi-pixel linear mode photon-counting HgCdTe avalanche photodiode (APD) array with near quantum limited sensitivity at near to mid infrared wavelengths where many fiber lasers and diode lasers operate. The instrument is modular and versatile and can be built mostly with components developed by the optical communication industry.

2.
Article in English | MEDLINE | ID: mdl-34804348

ABSTRACT

At NASA Goddard Space Flight Center, we have been developing spaceborne lidar instruments for space sciences. We have successfully flown several missions in the past based on mature diode pumped solid-state laser transmitters. In recent years, we have been developing advanced laser technologies for applications such as laser spectroscopy, laser communications, and interferometry. In this article, we will discuss recent experimental progress on these systems and instrument prototypes for ongoing development.

3.
Opt Express ; 25(14): 16589-16602, 2017 Jul 10.
Article in English | MEDLINE | ID: mdl-28789161

ABSTRACT

We report results from characterizing the HgCdTe avalanche photodiode (APD) arrays developed for lidar at infrared wavelengths by using the high density vertically integrated photodiodes (HDVIP®) technique. The results show >90% quantum efficiencies between 0.8 µm and the cut-off wavelength, >600 APD gain, near unity excess noise factor, 6-10 MHz electrical bandwidth and <0.5 fW/Hz1/2 noise equivalent power (NEP). The detectors provide linear analog output with a dynamic range of 2-3 orders of magnitude at a fixed APD gain without averaging, and over 5 orders of magnitude by adjusting the APD gain settings. They have been used successfully in airborne CO2 and CH4 integrated path differential absorption (IPDA) lidar as precursors for use in space lidar.

4.
Med Biol Eng Comput ; 55(4): 585-593, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27370786

ABSTRACT

This study determined if high-frequency biphasic stimulation can induce nerve conduction block that persists after the stimulation is terminated, i.e., post-stimulation block. The frog sciatic nerve-muscle preparation was used in the study. Muscle contraction force induced by low-frequency (0.5 Hz) nerve stimulation was recorded to indicate the occurrence and recovery of nerve block induced by the high-frequency (5 or 10 kHz) biphasic stimulation. Nerve block was observed during high-frequency stimulation and after termination of the stimulation. The recovery from post-stimulation block occurred in two distinct phases. During the first phase, the complete block induced during high-frequency stimulation was maintained. The average maximal duration for the first phase was 107 ± 50 s. During the second phase, the block gradually or abruptly reversed. The duration of both first and second phases was dependent on stimulation intensity and duration but not frequency. Stimulation of higher intensity (1.4-2 times block threshold) and longer duration (5 min) produced the longest period (249 ± 58 s) for a complete recovery. Post-stimulation block can be induced by high-frequency biphasic stimulation, which is important for future investigations of the blocking mechanisms and for optimizing the stimulation parameters or protocols in clinical applications.


Subject(s)
Electric Stimulation Therapy/methods , Nerve Block/methods , Sciatic Nerve/physiology , Animals , Axons/physiology , Muscle Contraction/physiology , Neural Conduction/physiology , Time Factors , Xenopus laevis
5.
Article in English | MEDLINE | ID: mdl-26217217

ABSTRACT

This study used the Frankenhaeuser-Huxley axonal model to analyze the effects of non-symmetric waveforms on conduction block of myelinated axons induced by high-frequency (10-300 kHz) biphasic electrical stimulation. The results predict a monotonic relationship between block threshold and stimulation frequency for symmetric waveform and a non-monotonic relationship for non-symmetric waveforms. The symmetric waveform causes conduction block by constantly activating both sodium and potassium channels at frequencies of 20-300 kHz, while the non-symmetric waveforms share the same blocking mechanism from 20 kHz up to the peak threshold frequency. At the frequencies above the peak threshold frequency the non-symmetric waveforms block axonal conduction by either hyperpolarizing the membrane (if the positive pulse is longer) or depolarizing the membrane (if the negative pulse is longer). This simulation study further increases our understanding of conduction block in myelinated axons induced by high-frequency biphasic electrical stimulation, and can guide future animal experiments as well as optimize stimulation parameters that might be used for electrically induced nerve block in clinical applications.

6.
J Comput Neurosci ; 37(2): 377-86, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24928360

ABSTRACT

The effect of a non-symmetric waveform on nerve conduction block induced by high-frequency biphasic stimulation is investigated using a lumped circuit model of the unmyelinated axon based on Hodgkin-Huxley equations. The simulation results reveal that the block threshold monotonically increases with the stimulation frequency for the symmetric stimulation waveform. However, a non-monotonic relationship between block threshold and stimulation frequency is observed when the stimulation waveform is non-symmetric. Constant activation of potassium channels by the high-frequency stimulation results in the increase of block threshold with increasing frequency. The non-symmetric waveform with a positive pulse 0.4-0.8 µs longer than the negative pulse blocks axonal conduction by hyperpolarizing the membrane and causes a decrease in block threshold as the frequency increases above 12-16 kHz. On the other hand, the non-symmetric waveform with a negative pulse 0.4-0.8 µs longer than the positive pulse blocks axonal conduction by depolarizing the membrane and causes a decrease in block threshold as the frequency increases above 40-53 kHz. This simulation study is important for understanding the potential mechanisms underlying the nerve block observed in animal studies, and may also help to design new animal experiments to further improve the nerve block method for clinical applications.


Subject(s)
Axons/physiology , Models, Neurological , Nerve Fibers, Unmyelinated/physiology , Neural Conduction/physiology , Action Potentials/physiology , Electric Stimulation
7.
Neuromodulation ; 17(5): 490-6; discussion 496, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24320615

ABSTRACT

OBJECTIVE: The study aims to determine the functionality of a wireless-controlled implantable stimulator designed for stimulation and block of the pudendal nerve. MATERIALS AND METHODS: In five cats under α-chloralose anesthesia, the stimulator was implanted underneath the skin on the left side in the lower back along the sacral spine. Two tripolar cuff electrodes were implanted bilaterally on the pudendal nerves in addition to one bipolar cuff electrode that was implanted on the left side central to the tripolar cuff electrode. The stimulator provided high-frequency (5-20 kHz) biphasic stimulation waveforms to the two tripolar electrodes and low-frequency (1-100 Hz) rectangular pulses to the bipolar electrode. Bladder and urethral pressures were measured to determine the effects of pudendal nerve stimulation (PNS) or block. RESULTS: The maximal (70-100 cmH2O) urethral pressure generated by 20-Hz PNS applied via the bipolar electrode was completely eliminated by the pudendal nerve block induced by the high-frequency stimulation (6-15 kHz, 6-10 V) applied via the two tripolar electrodes. In a partially filled bladder, 20-30 Hz PNS (2-8 V, 0.2 ms) but not 5 Hz stimulation applied via the bipolar electrode elicited a large sustained bladder contraction (45.9 ± 13.4 to 52.0 ± 22 cmH2O). During cystometry, the 5 Hz PNS significantly (p < 0.05) increased bladder capacity to 176.5 ± 27.1% of control capacity. CONCLUSIONS: The wireless-controlled implantable stimulator successfully generated the required waveforms for stimulation and block of pudendal nerve, which will be useful for restoring bladder functions after spinal cord injury.


Subject(s)
Electric Stimulation/methods , Pudendal Nerve/physiology , Wireless Technology , Animals , Biophysics , Cats , Female , Male , Nerve Block , Urinary Bladder/immunology