Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Mater Horiz ; 11(3): 646-660, 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38063132

ABSTRACT

Manipulation of the surface properties of the triboelectric layer has been proven to be one of the key parameters to achieve high-performance and stable triboelectric nanogenerators (TENG). Herein, a pragmatic surface engineering strategy that can substantially boost the performance and stability of flexible TENG is elaborated by incorporating the zwitterionic molecule dimethylethylammoniumpropane sulfonate (NDSB) as the surface modification layer. Given that zwitterionic molecules tend to form aggregated structures, realizing ordered arrangement on the substrate surface remains challenging to date. To address this issue, in this work, a combination of multiple surface treatments and molecular manipulation strategy is proposed. Our results prove that NDSB is effective in modifying the surface properties of the dielectric layer and electrode layer, leading to a remarkable power density and specific power of 2.86 W m-2 and 20.73 mW g-1 for flexible TENG, respectively. In addition, due to the strong interaction between the NDSB/dielectric and NDSB/electrode, a water-resistant long-term stable flexible TENG is realized. More encouragingly, our strategy is compatible with a cost-effective dip-coating technique, and an unprecedented demonstration of batch fabrication of TENG using NDSB to functionalize the surface of the dielectric layer and electrode layer synchronously can be realized, which is advantageous for rapid and up-scalable manufacturing of TENG. We also prove that the TENG based on zwitterionic materials reveals exceptional antibacterial properties against Escherichia coli. This study represents an important step towards the development of long-term stable flexible TENG that possesses a high output performance and excellent antibacterial activity based on a facile and economical strategy, enabling TENG technology to show bright prospects in a wide variety of application domains.

2.
Ann Plast Surg ; 90(1 Suppl 1): S2-S9, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36752416

ABSTRACT

BACKGROUND: LeFort I osteotomy changes the morphology of the nose. The cinch suture has been proven to prevent the increase in nasal base and alar width. Different types of cinch sutures have been proposed. However, their effectiveness is unclear. AIM AND OBJECTIVES: The aim of this study was to compare the surgical outcomes between conventional and modified cinch techniques through a systematic review and meta-analysis of randomized control trials (RCTs). MATERIAL AND METHODS: We performed systematic search from Embase, PubMed, and the Cochrane Library according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement up to March 2021. The surgical techniques of different cinch sutures were reviewed, and the outcomes of nasal alar width and alar base width were compared between modified and conventional methods. RESULTS: A total of 4 eligible RCTs were included in this meta-analysis. Pooled data showed no significant difference in alar base width change between modified and conventional methods (mean difference, -0.37; 95% confidence interval, -1.32 to 0.57; P = 0.44). Pooled data of 3 studies also showed no significant difference in nasal alar width change (mean difference, -0.11; 95% confidence interval, -1.18 to 0.95; P = 0.83). CONCLUSION: Based on the current data pooled from the available RCTs, no significant difference was found between the conventional cinch technique and the modified technique.


Subject(s)
Maxilla , Nasal Cartilages , Humans , Nasal Cartilages/surgery , Maxilla/surgery , Osteotomy, Le Fort/methods , Nose/surgery , Suture Techniques
3.
Sci Rep ; 12(1): 7893, 2022 05 12.
Article in English | MEDLINE | ID: mdl-35550552

ABSTRACT

This study analyzed the outcomes of zygomatico-orbital fracture reconstruction using the real-time navigation system with intraoperative three-dimensional (3D) C-arm computed tomography (CT). Fifteen patients with zygomatico-orbital or isolated orbital/zygoma fractures were enrolled in this prospective cohort. For zygoma reduction, the displacement at five key sutures and the differences between preoperative and intraoperative CT images were compared. For orbital reconstruction, the bilateral orbital volume differences in the anterior, middle, and posterior angles over the medial transitional buttress were measured. Two patients required implant adjustment once after the intraoperative 3D C-arm assessment. On comparing the preoperative and postoperative findings for the zygoma, the average sum of displacement was 19.48 (range, 5.1-34.65) vs. 1.96 (0-3.95) mm (P < 0.001) and the deviation index was 13.56 (10-24.35) vs. 2.44 (0.6-4.85) (P < 0.001). For the orbit, the mean preoperative to postoperative bilateral orbital volume difference was 3.93 (0.35-10.95) vs. 1.05 (0.12-3.61) mm3 (P < 0.001). The mean difference in the bilateral angles at the transition buttress was significantly decreased postoperatively at the middle and posterior one-third. There was no significant difference in orbital volume, angle of the transition zone, and the sum of five zygoma distances between post operative results and preoperative virtual planning. The surgical navigation system with the intraoperative 3D C-arm can effectively improve the accuracy of zygomatico-orbital fracture reconstruction and decrease implant adjustment times.


Subject(s)
Orbital Fractures , Plastic Surgery Procedures , Surgery, Computer-Assisted , Humans , Orbit/diagnostic imaging , Orbit/surgery , Orbital Fractures/diagnostic imaging , Orbital Fractures/surgery , Prospective Studies , Plastic Surgery Procedures/methods , Surgery, Computer-Assisted/methods , Surgical Navigation Systems , Tomography, X-Ray Computed
4.
J Plast Reconstr Aesthet Surg ; 75(1): 424-432, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34257033

ABSTRACT

BACKGROUND: Inappropriate treatment of zygomatic fractures can reduce esthetic and functional outcomes. The aim of this study was to answer the research question: "Among patients with a unilateral zygomatic fracture, is the use of computer-assisted real-time navigation system during fracture reduction precise and accurate to create postoperative facial symmetry?" METHODS: Using a retrospective cohort study design, we enrolled a cohort of unilateral zygomatic fractures undergoing open reduction and internal fixation (ORIF) with the aid of the computer-based navigation system at Chang Gung Memorial Hospital, Taiwan, during January 2015 and March 2018. The predictor variable was the comparison before and after surgery. The main outcome variables included (1) two-dimensional (2D) reduction of the displacement at five anatomical landmarks: zygomaticofrontal, inferior orbital rim, zygomaticosphenoidal, zygomaticomaxillary, and zygomaticotemporal lines/buttresses and (2) three-dimensional (3D) differences on distances between zygomatic surface to the porion plane and the midpoint of zygomatic arch (ZA) to the mid-porion (MP) plane. The Wilcoxon signed-rank test was computed to compare between pre- and postoperative data, and a p-value less than 0.05 was considered statistically significant. RESULTS: The cohort comprised 24 subjects (50% females, 75% left-sided) with a mean age of 30.5 +/- 13.8 years. On 2D analysis, the significant fracture reduction was found: 4.78 vs. 1.22 mm, 1.78 vs. 0.40 mm, 3.50 vs. 0.07 mm, 3.06 vs. 0.55 mm, and 2.55 vs. 0.50 mm at zygomaticomaxillary, zygomaticofrontal, inferior orbital rim, zygomaticosphenoidal, and zygomaticotemporal landmarks. The 3D evaluations revealed the significant reduction of the differences between the left and right zygomatic surface to the porion plane (4.09 ± 2.12 vs. 0.46 ± 0.35 mm) and between the left and right ZA midpoints to the MP plane (4.89 ± 2.59 vs. 0.71 ± 0.44 mm) (p<0.001 for both 2D and 3D analyses). CONCLUSIONS: The results of this study suggest that the real-time surgical navigation system can effectively guide the ORIF of zygomatic fractures. Future research studies should focus on the learning curve and cost-effectiveness analysis of this technique.


Subject(s)
Surgery, Computer-Assisted , Zygomatic Fractures , Adolescent , Adult , Female , Fracture Fixation , Fracture Fixation, Internal/methods , Humans , Male , Retrospective Studies , Surgery, Computer-Assisted/methods , Young Adult , Zygomatic Fractures/surgery
5.
Arch Plast Surg ; 48(5): 483-493, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34583432

ABSTRACT

BACKGROUND: Direct-to-implant (DTI) breast reconstruction after nipple-sparing mastectomy (NSM) with the use of acellular dermal matrix (ADM) provides reliable outcomes; however, the use of ADM is associated with a higher risk of complications. We analyzed our experiences of post-NSM DTI without ADM and identified the predictive factors of adverse surgical outcomes. METHODS: Patients who underwent NSM and immediate DTI or two-stage tissue expander (TE) breast reconstruction from 2009 to 2020 were enrolled. Predictors of adverse endpoints were analyzed. RESULTS: There were 100 DTI and 29 TE reconstructions. The TE group had a higher rate of postmastectomy radiotherapy (31% vs. 11%; P=0.009), larger specimens (317.37±176.42 g vs. 272.08±126.33 g; P=0.047), larger implants (360.84±85.19 g vs. 298.83±81.13 g; P=0.004) and a higher implant/TE exposure ratio (10.3% vs. 1%; P=0.035). In DTI reconstruction, age over 50 years (odds ratio [OR], 5.43; 95% confidence interval [CI], 1.50-19.74; P=0.010) and a larger mastectomy weight (OR, 1.65; 95% CI, 1.08-2.51; P=0.021) were associated with a higher risk of acute complications. Intraoperative radiotherapy for the nipple-areolar complex increased the risk of acute complications (OR, 4.05; 95% CI, 1.07-15.27; P=0.039) and the likelihood of revision surgery (OR, 5.57; 95% CI, 1.25-24.93; P=0.025). CONCLUSIONS: Immediate DTI breast reconstruction following NSM is feasible in Asian patients with smaller breasts.

6.
BMC Cancer ; 21(1): 522, 2021 May 08.
Article in English | MEDLINE | ID: mdl-33964927

ABSTRACT

BACKGROUND: Neoadjuvant chemotherapy (NACT) was initially applied to locally advanced breast cancer to convert advanced lesions to an operable status. Currently, its application has been expanded to enhance overall oncological results, especially in patients with triple-negative or HER-2-positive breast cancer. With more NACT being applied, the role and impact of this approach on breast reconstruction needs to be determined. This study aimed to perform a complete reconstructive outcome analysis of patients receiving NACT who underwent immediate breast reconstruction. METHODS: A retrospective review of a single reconstructive surgeon's immediate breast reconstructions performed from July 2008 to December 2018 was undertaken. The results were stratified by the use of NACT. Patient demographics, delivery of NACT, adjuvant treatment, incidence of surgical complications, and postoperative photographs were analyzed. RESULTS: A total of 269 patients were included. The mean follow-up was 46.3 months. Forty-six out of 269 patients received NACT and were included in the NACT group. The other patients were included in the non-NACT group. When implant-based reconstruction was planned, the NACT group had a higher rate of two-stage tissue expander-implant reconstruction than direct-to-implant reconstruction (p < 0.001). The requirement for postmastectomy radiotherapy was higher in the NACT group (p < 0.001). The surgical complication rates were similar between groups after adjusting for confounding factors. The objective aesthetic outcomes assessed by 6 plastic surgeons were also similar between groups. CONCLUSIONS: Immediate breast reconstruction is a safe and reliable procedure, with an acceptable reconstructive complication rate and satisfactory aesthetic outcomes, for patients treated with NACT.


Subject(s)
Breast Neoplasms/surgery , Mammaplasty/adverse effects , Adult , Breast Neoplasms/drug therapy , Chemotherapy, Adjuvant , Cross-Sectional Studies , Female , Humans , Mastectomy , Middle Aged , Neoadjuvant Therapy , Postoperative Complications/etiology , Retrospective Studies
7.
World Neurosurg ; 125: e563-e574, 2019 05.
Article in English | MEDLINE | ID: mdl-30716485

ABSTRACT

OBJECTIVE: The role of maxillofacial trauma in dementia risk is not well established. The aim of this study was to evaluate the association between craniofacial trauma, including facial bone fracture and traumatic brain injury (TBI), and dementia. METHODS: Using Taiwan's National Health Insurance Research Database, we identified 501,889 adults who had had ≥1 medical record of craniofacial trauma between 2000 and 2010 and did not have a dementia diagnosis at baseline. Diagnoses of craniofacial trauma, including facial bone fracture and TBI, and dementia were made using International Classification of Diseases, Ninth Revision codes. The standardized incidence ratio was used to determine whether craniofacial trauma was associated with a greater risk of incident dementia compared with the general population. The Cox proportional hazards model was used to predict the risk of dementia among the trauma cohort by comparing the patients with and without comorbidities. RESULTS: A total of 501,889 patients with craniofacial trauma were included, of which 1.5% (n = 7804) developed dementia. Facial bone fracture (standardized incidence ratio, 1.58; 95% confidence interval, 1.25-2.00) was shown to be associated with an increased dementia risk compared with the general population. In addition, craniofacial trauma accompanied with postinjury comorbidities was associated with an increased risk of dementia during follow-up periods compared with the group without comorbidities. CONCLUSIONS: Craniofacial traumas, especially facial bone fracture, were associated with an increased risk of subsequent dementia. Maintaining a high index of suspicion for associated TBIs in all patients with facial trauma is crucial, even if no obvious initial signs and symptoms of brain injury are observed.


Subject(s)
Dementia/etiology , Skull Fractures/complications , Age Factors , Aged , Aged, 80 and over , Brain Injuries, Traumatic/etiology , Cohort Studies , Databases, Factual , Female , Humans , International Classification of Diseases , Male , Middle Aged , Proportional Hazards Models , Risk Factors
8.
Ann Plast Surg ; 82(1S Suppl 1): S77-S85, 2019 01.
Article in English | MEDLINE | ID: mdl-30516560

ABSTRACT

BACKGROUND AND PURPOSE: Extensive orbital floor and medial wall fractures compared with isolated orbital wall fractures are more likely to require surgical correction because of a higher possibility of complications like diplopia, enophthalmos, or numbness. The unique and complex contours of the orbital anatomy limit the intraoperative view of the intraorbital anatomy, and complex orbital fractures involving the buttress of the transition zone area all make orbital reconstruction surgery more challenging. The aim of this study was to describe our experience with surgical approaches using navigation- and endoscope-assisted guidance for extensive orbital floor and medial wall fracture reconstruction. PATIENTS AND METHODS: A retrospective study was conducted on consecutive 17 patients from 2015 to 2017 presenting with unilateral extensive orbital floor and medial wall fractures at the Chang Gung Memorial Hospital, Linkou Branch. The fractures were treated surgically with a preformed mesh plate and layered Medpor (Porex Surgical Inc, Atlanta, Ga) through navigation and endoscopy. The preoperative and postoperative functional and aesthetic outcomes were described. RESULTS: All extensive orbital floor and medial wall fractures were successfully reconstructed. Of the 17 patients, 11 experienced diplopia preoperatively, and for 2 of the 11 patients, diplopia improved immediately after surgery. In the remaining 9 patients, diplopia still persisted after surgery; however, diplopia recovered after an average of 3.44 months (range, 1-9 months). Average enophthalmos among the 10 patients, evaluated by postoperative follow-up computed tomography scan, improved from 2.99 to 0.68 mm. There were no major complications during follow-up, and all patients were satisfied with their final appearance and function. CONCLUSIONS: On the basis of the results, our surgical approach using preformed titanium mesh plates and Medpor under the assistance of navigation and endoscopy can be a safe, accurate, and effective method for the management of extensive orbital floor and medial wall fractures and clearly optimizes functional and aesthetic outcomes.


Subject(s)
Endoscopy/methods , Orbital Fractures/surgery , Plastic Surgery Procedures/methods , Prosthesis Implantation/methods , Surgery, Computer-Assisted/methods , Surgical Mesh , Adult , Cohort Studies , Female , Follow-Up Studies , Fracture Fixation/methods , Fracture Healing/physiology , Humans , Injury Severity Score , Male , Orbital Fractures/diagnostic imaging , Patient Safety , Polyethylenes , Postoperative Complications/epidemiology , Postoperative Complications/physiopathology , Prognosis , Retrospective Studies , Risk Assessment , Surgery, Computer-Assisted/adverse effects , Titanium , Tomography, X-Ray Computed/methods , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...