1.
Article in English | MEDLINE | ID: mdl-35722148

ABSTRACT

Background: Danshen Decoction comprises Salvia miltiorrhiza, Santalum album, and Amomum villosum. It can promote blood circulation and remove blood stasis, and is commonly used in the treatment of gastric and duodenal ulcers, coronary heart disease, angina pectoris, etc. This research is based on network pharmacology and is experimentally verified to explore the potential mechanism of Danshen Decoction in the treatment of ischemic cardiomyopathy (ICM). Methods: The effective components and targets of Danshen Decoction were firstly extracted from Traditional Chinese Medicine Systems Pharmacology (TCMSP) Database and Analysis Platform, the drug-component-target-disease network was then constructed, the protein-protein interaction (PPI) network was constructed, the Gene Ontology (GO) enrichment analysis was carried out, and the Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway was analyzed in order to find the potential active components and therapeutic mechanisms. Finally, the in vitro hypoxia/reoxygenation model in H9c2 cells was established to verify the predicted active components and therapeutic mechanisms. Results: The results showed that Danshen Decoction has 67 potential active components and 109 therapeutic targets in treating ICM. These targets were rich in a variety of gene functions and different signaling pathways; the main gene targets include TP53, c-Jun, and Akt1. Go enrichment analysis showed that response to drug, membrane raft, and G protein-coupled amine receiver activity rank first in each process, and the main signaling pathways include PI3K-Akt signaling pathway. Through molecular docking and experimental verification of the major active components and core therapeutic targets, the active components of Danshen Decoction demonstrated an ability to reduce the cell damage caused by hypoxia/reoxygenation in H9c2 cells by regulating the core therapeutic target including Akt1, c-Jun, and TP53. Conclusion: Danshen Decoction has the effect of treating ICM in multiple ways, which is consistent with the results of network pharmacology. This laid a foundation for further study in exploring the active principles and pharmacological mechanism of Danshen Decoction.

2.
Article in English | MEDLINE | ID: mdl-35126599

ABSTRACT

BACKGROUND: Our previous studies have demonstrated a protective role of Zhilong Huoxue Tongyu capsule in atherosclerosis (AS); however, the molecular mechanisms are unclear. METHODS: Human coronary artery endothelial cells (HCAECs) were induced with oxidized low-density lipoprotein (ox-LDL) to obtain cellular AS models. Then, the medicated serum of Zhilong Huoxue Tongyu capsule was obtained and used for treatment with ox-LDL-induced HCAECs. The cell viability was detected by CCK-8 assay. Besides, the binding between miR-30b-5p and NLRP3 was determined by the dual-luciferase reporter gene system assay. Furthermore, ox-LDL-induced HCAECs were transfected with miR-30b-5p mimic or miR-30b-5p inhibitor. The pyroptosis of HCAECs was assessed by flow cytometry, LDH content detection, and qRT-PCR assays. RESULTS: 10% medicated serum of Zhilong Huoxue Tongyu capsule was the maximum nontoxic concentration and it was used in subsequent assays. The rate of pyroptosis, LDH content, and the mRNA expression level of pyroptosis-related genes including NLRP3, ASC, Caspase 1, IL-1ß, and IL-18 were prominently enhanced after HCAECs were induced by ox-LDL, which were markedly rescued with medicated serum of Zhilong Huoxue Tongyu capsule. In addition, the medicated serum of Zhilong Huoxue Tongyu capsule significantly enhanced the ox-LDL-induced reduction of miR-30b-5p level. NLRP3 could bind to miR-30b-5p and was negatively corrected with miR-30b-5p. Moreover, all the rates of pyroptosis, LDH content, and the mRNA expression levels of pyroptosis-related genes including NLRP3, ASC, Caspase 1, IL-1ß, and IL-18 were further observably decreased after ox-LDL-induced HCAECs treated with medicated serum were transfected with miR-30b-5p mimic, while these were significantly rescued with transfection of miR-30b-5p inhibitor. CONCLUSION: Zhilong Huoxue Tongyu capsule alleviated the pyroptosis of vascular endothelial cells induced by ox-LDL through miR-30b-5p/NLRP3.

3.
J Clin Lab Anal ; 29(2): 146-52, 2015 Mar.
Article in English | MEDLINE | ID: mdl-24797498

ABSTRACT

BACKGROUND: Fourth-generation human immunodeficiency virus (HIV) screening assays have been used in many laboratories. The Elecsys® HIV combi PT assay is a new kind of fourth-generation HIV screening assay developed to allow earlier detection of seroconversion. METHODS: A total of 271,845 routine specimens were detected using the Elecsys® HIV combi assay and Elecsys® HIV combi PT assay from September 2010 to December 2012 in a large university hospital. Repeatedly, reactive screening samples were confirmed according to recommended confirmatory algorithms. RESULTS: The false-positive rate and positive predictive value (PPV) of two assays are 0.08 and 78.35%, respectively, for the Elecsys® HIV combi assay and 0.07 and 82.21% for the Elecsys® HIV combi PT assay. Ninety-four percent cases with cutoff index ratio <15.0 were false-positive. When we set the specificity as 95.0 and 99.0%, PPV could increase to 98.7, 99.6, 98.8, and 99.7%, and sensitivity reduced to 99.2, 98.4, 98.5, and 96.8% for the Elecsys® HIV combi assay and the Elecsys® HIV combi PT assay, respectively. CONCLUSIONS: The Elecsys® HIV combi PT assay shows a better performance in specificity than the Elecsys® HIV combi assay. Most weakly reactive results were false-positive, this means it still need to be improved and it will need laboratory personnel to communicate with the clinical doctor and patients more properly about the result of the assay.


Subject(s)
HIV/isolation & purification , Hospitals , Immunoassay/methods , Autoanalysis/methods , China , False Positive Reactions , HIV Infections/diagnosis , HIV Infections/virology , HIV-1/isolation & purification , Humans , Mass Screening , Quality Control , Reagent Kits, Diagnostic , Sensitivity and Specificity
4.
Int J STD AIDS ; 25(4): 267-72, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23970655

ABSTRACT

A new fourth-generation HIV Ag/Ab electrochemiluminescence immunoassay for screening of HIV infection, the Elecsys HIV Combi PT (Roche Diagnostics, Penzberg, Germany) assay, is going to be commercially available in clinical laboratories in China. This assay was evaluated and compared with two commonly used assays: Elecsys HIV Combi assay and the Livzon anti-HIV-1/2 ELISA. Commercially available panels and 30 established HIV infection samples were tested to evaluate the sensitivity. In addition, a total of 675 routine clinical samples were collected and tested in West China Hospital to compare the specificity. Any reactive result from a screening test was retested and all reactive retested samples were confirmed with Western blot assay, Elecsys HIV Ag test, Elecsys HIV Ag confirmatory test or HIV-1 RNA NAT testing. According to the results of the HIV seroconversion panels, the Elecsys HIV Combi PT could detect seroconversion at the same bleed or at least one bleed earlier compared to the other two assays. Among the 675 clinical samples, most results were consistent except for one specimen with a false-negative result using Elecsys HIV Combi assay. In conclusion, the Elecsys HIV Combi PT has shown satisfactory sensitivity and specificity to be a screening test for HIV infection.


Subject(s)
HIV Antibodies/blood , HIV Core Protein p24/blood , HIV Infections/diagnosis , HIV-1/isolation & purification , HIV-2/isolation & purification , Immunoassay/methods , Reagent Kits, Diagnostic/standards , Blotting, Western , China , Enzyme-Linked Immunosorbent Assay , HIV Antibodies/immunology , HIV Core Protein p24/immunology , HIV Infections/immunology , Humans , Immunoassay/standards , Mass Screening/methods , RNA, Viral/blood , Reproducibility of Results , Sensitivity and Specificity
5.
PLoS One ; 7(10): e48162, 2012.
Article in English | MEDLINE | ID: mdl-23144740

ABSTRACT

BACKGROUND: The recent approval of 4th generation HIV tests has forced many laboratories to decide whether to shift from 3rd to these tests. There are limited published studies on the comparative evaluation of these two different assays. We compare the performance of fourth-generation electrochemiluminescence immunoassay (ChIA) and third-generation enzyme linked immunosorbent assay (EIA) for human immunodeficiency virus (HIV) screening and gauge whether the shift from EIA to ChIA could be better in a multiethnic region of China. METHODOLOGY/PRINCIPAL FINDINGS: We identified a large number of routine specimens (345,492) using two different assays from Jan 2008 to Aug 2011 in a teaching hospital with high sample throughput. Of the 344,596 specimens with interpretable HIV test results, 526(0.23%) of 228,761 using EIA and 303(0.26%) of 115,835 using ChIA were HIV-1 positive. The false-positive rate of EIA was lower than that of ChIA [0.03% vs. 0.08%, odds ratio 0.33 (95% confidence interval 0.24, 0.45)]. The positive predictive value (PPV) of EIA (89.6%) was significantly higher than that of ChIA (76.1%) (<0.001), reflecting the difference between the two assays. The clinical sensitivities of two assays in this study were 99.64% for EIA and 99.88% for ChIA. CONCLUSION: Caution is needed before shifting from 3rd to 4th generation HIV tests. Since none of these tests are perfect, different geographic and ethnic area probably require different considerations with regard to HIV testing methods, taking into account the local conditions.


Subject(s)
Enzyme-Linked Immunosorbent Assay/methods , HIV Infections/diagnosis , HIV Infections/immunology , HIV-1/immunology , Immunoassay/methods , Mass Screening/methods , AIDS Serodiagnosis/methods , Blotting, Western , China , Electrochemical Techniques/methods , False Positive Reactions , HIV Antibodies/blood , HIV Antibodies/immunology , HIV Infections/blood , Humans , Luminescent Measurements/methods , Reagent Kits, Diagnostic , Reproducibility of Results , Sensitivity and Specificity