ABSTRACT

PURPOSE: To develop and validate a predictive combined model for metastasis in patients with clear cell renal cell carcinoma (ccRCC) by integrating multimodal data. MATERIALS AND METHODS: In this retrospective study, the clinical and imaging data (CT and ultrasound) of patients with ccRCC confirmed by pathology from three tertiary hospitals in different regions were collected from January 2013 to January 2023. We developed three models, including a clinical model, a radiomics model, and a combined model. The performance of the model was determined based on its discriminative power and clinical utility. The evaluation indicators included area under the receiver operating characteristic curve (AUC) value, accuracy, sensitivity, specificity, negative predictive value, positive predictive value and decision curve analysis (DCA) curve. RESULTS: A total of 251 patients were evaluated. Patients (n = 166) from Shandong University Qilu Hospital (Jinan) were divided into the training cohort, of which 50 patients developed metastases; patients (n = 37) from Shandong University Qilu Hospital (Qingdao) were used as internal testing, of which 15 patients developed metastases; patients (n = 48) from Changzhou Second People's Hospital were used as external testing, of which 13 patients developed metastases. In the training set, the combined model showed the highest performance (AUC, 0.924) in predicting lymph node metastasis (LNM), while the clinical and radiomics models both had AUCs of 0.845 and 0.870, respectively. In the internal testing, the combined model had the highest performance (AUC, 0.877) for predicting LNM, while the AUCs of the clinical and radiomics models were 0.726 and 0.836, respectively. In the external testing, the combined model had the highest performance (AUC, 0.849) for predicting LNM, while the AUCs of the clinical and radiomics models were 0.708 and 0.804, respectively. The DCA curve showed that the combined model had a significant prediction probability in predicting the risk of LNM in ccRCC patients compared with the clinical model or the radiomics model. CONCLUSION: The combined model was superior to the clinical and radiomics models in predicting LNM in ccRCC patients.

2.
Front Cardiovasc Med ; 10: 1024773, 2023.
Article in English | MEDLINE | ID: mdl-36742075

ABSTRACT

Objective: The present study aimed to predict myocardial ischemia in coronary heart disease (CHD) patients based on the radiologic features of coronary computed tomography angiography (CCTA) combined with clinical factors. Methods: The imaging and clinical data of 110 patients who underwent CCTA scan before DSA or FFR examination in Changzhou Second People's Hospital, Nanjing Medical University (90 patients), and The First Affiliated Hospital of Soochow University (20 patients) from March 2018 to January 2022 were retrospectively analyzed. According to the digital subtraction angiography (DSA) and fractional flow reserve (FFR) results, all patients were assigned to myocardial ischemia (n = 58) and normal myocardial blood supply (n = 52) groups. All patients were further categorized into training (n = 64) and internal validation (n = 26) sets at a ratio of 7:3, and the patients from second site were used as external validation. Clinical indicators of patients were collected, the left ventricular myocardium were segmented from CCTA images using CQK software, and the radiomics features were extracted using pyradiomics software. Independent prediction models and combined prediction models were established. The predictive performance of the model was assessed by calibration curve analysis, receiver operating characteristic (ROC) curve and decision curve analysis. Results: The combined model consisted of one important clinical factor and eight selected radiomic features. The area under the ROC curve (AUC) of radiomic model was 0.826 in training set, and 0.744 in the internal validation set. For the combined model, the AUCs were 0.873, 0.810, 0.800 in the training, internal validation, and external validation sets, respectively. The calibration curves demonstrated that the probability of myocardial ischemia predicted by the combined model was in good agreement with the observed values in both training and validation sets. The decision curve was within the threshold range of 0.1-1, and the clinical value of nomogram was higher than that of clinical model. Conclusion: The radiomic characteristics of CCTA combined with clinical factors have a good clinical value in predicting myocardial ischemia in CHD patients.

3.
J Xray Sci Technol ; 30(4): 767-776, 2022.
Article in English | MEDLINE | ID: mdl-35527621

ABSTRACT

PURPOSE: To establish a machine-learning (ML) model based on coronary computed tomography angiography (CTA) images for evaluating myocardial ischemia in patients diagnosed with coronary atherosclerosis. METHODS: This retrospective analysis includes CTA images acquired from 110 patients. Among them, 58 have myocardial ischemia and 52 have normal myocardial blood supply. The patients are divided into training and test datasets with a ratio 7 : 3. Deep learning model-based CQK software is used to automatically segment myocardium on CTA images and extract texture features. Then, seven ML models are constructed to classify between myocardial ischemia and normal myocardial blood supply cases. Predictive performance and stability of the classifiers are determined by receiver operating characteristic curve with cross validation. The optimal ML model is then validated using an independent test dataset. RESULTS: Accuracy and areas under ROC curves (AUC) obtained from the support vector machine with extreme gradient boosting linear method are 0.821 and 0.777, respectively, while accuracy and AUC achieved by the neural network (NN) method are 0.818 and 0.757, respectively. The naive Bayes model yields the highest sensitivity (0.942), and the random forest model yields the highest specificity (0.85). The k-nearest neighbors model yields the lowest accuracy (0.74). Additionally, NN model demonstrates the lowest relative standard deviations (0.16 for accuracy and 0.08 for AUC) indicating the high stability of this model, and its AUC applying to the independent test dataset is 0.72. CONCLUSION: The NN model demonstrates the best performance in predicting myocardial ischemia using radiomics features computed from CTA images, which suggests that this ML model has promising potential in guiding clinical decision-making.


Subject(s)
Coronary Artery Disease , Myocardial Ischemia , Bayes Theorem , Humans , Machine Learning , Retrospective Studies , Tomography, X-Ray Computed
4.
J Xray Sci Technol ; 29(6): 1149-1160, 2021.
Article in English | MEDLINE | ID: mdl-34657848

ABSTRACT

OBJECTIVE: To develop and test an optimal machine learning model based on the enhanced computed tomography (CT) to preoperatively predict pathological grade of clear cell renal cell carcinoma (ccRCC). METHODS: A retrospective analysis of 53 pathologically confirmed cases of ccRCC was performed and 25 consecutive ccRCC cases were selected as a prospective testing set. All patients underwent routine preoperative abdominal CT plain and enhanced scans. Renal tumor lesions were segmented on arterial phase images and 396 radiomics features were extracted. In the training set, seven discrimination classifiers for high- and low-grade ccRCCs were constructed based on seven different machine learning models, respectively, and their performance and stability for predicting ccRCC grades were evaluated through receiver operating characteristic (ROC) analysis and cross-validation. Prediction accuracy and area under ROC curve were used as evaluation indices. Finally, the diagnostic efficacy of the optimal model was verified in the testing set. RESULTS: The accuracies and AUC values achieved by support vector machine with radial basis function kernel (svmRadial), random forest and naïve Bayesian models were 0.860±0.158 and 0.919±0.118, 0.840±0.160 and 0.915±0.138, 0.839±0.147 and 0.921±0.133, respectively, which showed high predictive performance, whereas K-nearest neighborhood model yielded lower accuracy of 0.720±0.188 and lower AUC value of 0.810±0.150. Additionally, svmRadial had smallest relative standard deviation (RSD, 0.13 for AUC, 0.17 for accuracy), which indicates higher stability. CONCLUSION: svmRadial performs best in predicting pathological grades of ccRCC using radiomics features computed from the preoperative CT images, and thus may have high clinical potential in guiding preoperative decision.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Bayes Theorem , Carcinoma, Renal Cell/diagnostic imaging , Humans , Kidney Neoplasms/diagnostic imaging , Machine Learning , Prospective Studies , Retrospective Studies , Tomography, X-Ray Computed/methods
5.
ACS Omega ; 5(40): 25848-25853, 2020 Oct 13.
Article in English | MEDLINE | ID: mdl-33073110

ABSTRACT

Massive attention has been paid to MXenes due to their intriguing properties and potential diverse applications. Extensive studies using first-principles calculations on the electronic structures of MXenes Cr2CO2 and Cr2NO2 were performed in this paper. Based on the accurate Heyd-Scuseria-Ernzerhof (HSE) calculations, Cr2CO2 is clarified to be a ferromagnetic semiconductor; meanwhile, Cr2NO2 is a half-metallic material, which is consistent with previous results. In particular, by analyzing the contribution of the orbitals to the band structures and density of states, the basic mechanism of ferromagnetism was analyzed in detail. Our theoretical work might promote the spintronics study and application of Cr-contained MXenes.

6.
J Opt Soc Am A Opt Image Sci Vis ; 35(6): 969-976, 2018 Jun 01.
Article in English | MEDLINE | ID: mdl-29877341

ABSTRACT

The sub-pixel arrangement of the RGBG panel and the image with RGB format are different and the algorithm that converts RGB to RGBG is urgently needed to display an image with RGB arrangement on the RGBG panel. However, the information loss is still large although color fringing artifacts are weakened in the published papers that study this conversion. In this paper, an RGB-to-RGBG conversion algorithm with adaptive weighting factors based on edge detection and minimal square error (EDMSE) is proposed. The main points of innovation include the following: (1) the edge detection is first proposed to distinguish image details with serious color fringing artifacts and image details which are prone to be lost in the process of RGB-RGBG conversion; (2) for image details with serious color fringing artifacts, the weighting factor 0.5 is applied to weaken the color fringing artifacts; and (3) for image details that are prone to be lost in the process of RGB-RGBG conversion, a special mechanism to minimize square error is proposed. The experiment shows that the color fringing artifacts are slightly improved by EDMSE, and the values of MSE of the image processed are 19.6% and 7% smaller than those of the image processed by the direct assignment and weighting factor algorithm, respectively. The proposed algorithm is implemented on a field programmable gate array to enable the image display on the RGBG panel.

SELECTION OF CITATIONS
SEARCH DETAIL
...