Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(2): 527-33, 2015 Feb.
Article in Chinese | MEDLINE | ID: mdl-25970926

ABSTRACT

The method for the determmation of trace boron, molybdenum, silver, tin and lead in geochemical samples by direct current are full spectrum direct reading atomic emission spectroscopy (DC-Arc-AES) was established. Direct current are full spectrum direct reading atomic emission spectrometer with a large area of solid-state detectors has functions of full spectrum direct reading and real-time background correction. The new electrodes and new buffer recipe were proposed in this paper, and have applied for national patent. Suitable analytical line pairs, back ground correcting points of elements and the internal standard method were selected, and Ge was used as internal standard. Multistage currents were selected in the research on current program, and each current set different holding time to ensure that each element has a good signal to noise ratio. Continuous rising current mode selected can effectively eliminate the splash of the sample. Argon as shielding gas can eliminate CN band generating and reduce spectral background, also plays a role in stabilizing the are, and argon flow 3.5 L x min(-1) was selected. Evaporation curve of each element was made, and it was concluded that the evaporation behavior of each element is consistent, and combined with the effects of different spectrographic times on the intensity and background, the spectrographic time of 35s was selected. In this paper, national standards substances were selected as a standard series, and the standard series includes different nature and different content of standard substances which meet the determination of trace boron, molybdenum, silver, tin and lead in geochemical samples. In the optimum experimental conditions, the detection limits for B, Mo, Ag, Sn and Pb are 1.1, 0.09, 0.01, 0.41, and 0.56 microg x g(-1) respectively, and the precisions (RSD, n=12) for B, Mo, Ag, Sn and Pb are 4.57%-7.63%, 5.14%-7.75%, 5.48%-12.30%, 3.97%-10.46%, and 4.26%-9.21% respectively. The analytical accuracy was validated by national standards and the results are in agreement with certified values. The method is simple, rapid, is an advanced analytical method for the determination of trace amounts of geochemical samples' boron, molybdenum, silver, tin and lead, and has a certain practicality.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(11): 3124-7, 2013 Nov.
Article in Chinese | MEDLINE | ID: mdl-24555395

ABSTRACT

A method for the determination of high content of tin in geochemical samples by solid emission spectrometry was presented. The dedicated high content tin spectrum standard series was developed. K2S2O7, NaF, Al2O3 and carbon powder were used as buffers and Ge was used as internal standard, and the ratio of sample/matrix/buffer is 1 : 1 : 2. A weak sensitive line (Sn 242. 170 0 nm) was used as the analytical line. The technologies of vertical electrodes, AC arc overlap spectrograph, interception of the exposure, quantitative computer translation spectrum and background correction were used. The determination range is 100-22 350 microg x g(-1), the detection limit is 16.64 microg x g(-1), and the precision is (RSD, n = 12) 4.11%-6.46%. The accuracy of the method has been verified by determination of high content of tin in national geochemical standard samples and the results are in agreement with certified value. The method can be used for measurement directly without dilution of high content of tin in geochemical samples, and it greatly improved the detection upper limit for the determination of tin with solid emission spectroscopy and has certain practical value.

SELECTION OF CITATIONS
SEARCH DETAIL
...