Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Publication year range
1.
Otol Neurotol ; 42(4): 524-531, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33710992

ABSTRACT

OBJECTIVE: To study the surgical results, intracochlear position of the electrode array (EA) and auditory performance of the LISTENT LCI-20PI cochlear implant device, and daily use status at 3 years. STUDY DESIGN: A retrospective study. SETTING: A single-tertiary referral center. PATIENTS: Between January and December 2016, 20 patients underwent cochlear implantation using the LISTENT LCI-20PI (lateral wall EA). INTERVENTION: Cochlear implantation. MAIN OUTCOME MEASURES: Measurement of cochlear size, extent of posterior tympanotomy, and insertion depth. Scalar position of the EA evaluated by 3D reconstruction. Auditory outcomes 1 year after implantation and daily use status at 3 years. RESULTS: EAs were completely inserted in all cases with an insertion depth of 288 ±â€Š36.8 degrees. One year later, the average sentence recognition score (SRS) was 90 ±â€Š21.7%. EA scalar location was analyzed in 18 patients. Thirteen EAs (72.2%) were fully inserted into the scala tympani (ST) and 5 (27.8%) had shifted from the ST to the scala vestibuli (SV). There was no statistically significant difference in cochlear size, extent of posterior tympanotomy, or insertion depth between these two groups. EAs inserted by cochleostomy had a higher chance of scalar shift than those inserted via the round window (60% vs 15.4%, p = 0.099). SRS at 1 year with full ST insertion was significantly better than in those with scalar shift (99 ±â€Š1.3% vs 83 ±â€Š16.5%, p = 0.002). Three years after implantation, 92% of patients were daily users and 46% were telephone users. CONCLUSIONS: The LISTENT LCI-20PI provided accredited hearing rehabilitation with a short insertion depth. Full insertion into the ST was associated with better cochlear implantation outcomes.


Subject(s)
Cochlear Implantation , Cochlear Implants , Cochlea/diagnostic imaging , Cochlea/surgery , Humans , Retrospective Studies , Scala Tympani/surgery
2.
Article in Chinese | MEDLINE | ID: mdl-33254341

ABSTRACT

Objective:To study the anatomical distribution and tumor extent of juvenile laryngeal papilloma(JLP), and to sum up the similarity and difference in distribution between initiatial and recurrent tumor. Method:Data of 65 patients with JLP who were admitted to the Ear Institute, School of Medicine, Shanghai Jiao Tong University from January 2011 to December 2018 were retrospectively analyzed. The RRP tumor assessment method proposed by Derkay et al. was referred to, in which larynx was divided in to 11 anatomical sites. Result:2.9±1.3 Laryngeal anatomical sites were involved in patients with initial tumor, while that was 3.1±1.5 in patients with recurrent tumor. The most common sites were true vocal fords, anterior commissure and false vocal fords in both group; and the least ones were subglottis, posterior glottis and ary-epiglottic fold. However, subglottis(P=0.038) and trachea(P=0.007) were more likely to be involved in recurrent tumor, with statistical differences. Conclusion:There were differences in distribution of JLP between initial and recurrent tumor, which might be the result of suitable areas for HPV survival or micro-lesion of residual tumor.


Subject(s)
Laryngeal Neoplasms , Larynx , Papillomavirus Infections , China/epidemiology , Humans , Respiratory Tract Infections , Retrospective Studies
3.
Biochem Biophys Res Commun ; 526(2): 328-333, 2020 05 28.
Article in English | MEDLINE | ID: mdl-32220497

ABSTRACT

OBJECTIVE: To develop a drug-eluting polymer film which can be easily personalized and rapidly made on the electrode array of a cochlear implant during surgery. METHODS: A precursor solution was prepared with poly lactic-co-glycolic acid (PLGA) and trichloromethane. Using a dip-coating method, the silicone electrode array (HiFocus 1J, Advanced Bionics) was coated in polymer film produced from the precursor solution containing one of three drugs: dexamethasone sodium phosphate (DSP), cytosine arabinoside hydrochloride (Ara-C), or nicotinamide adenine dinucleotide (NAD), and the release of these drugs from the polymer film was studied. The drug-eluting film on the electrode array was analyzed by environmental scanning electron microscopy (ESEM). The water contact angle and the impedance of the electrode array were measured before and after coating. Drug release kinetics was evaluated in a quasi-stationary release model, using high performance liquid chromatography every 24 h for 15 days. RESULTS: Five electrode arrays were tested with each of the three drugs in the polymer film coating. Before and after coating, ESEM studies revealed that the drug-loaded PLGA coating yielded a smooth covering with an average thickness of 1.02 ± 0.05 µm. The mass of the coated electrode increased by 1.00 ± 0.03 mg. The water contact angle decreased after coating (102 ± 0.6° vs 77 ± 1.6°, p < 0.01) but there was no significant change in the average impedance of the electrodes after coating (0.9 ± 0.22 kΩ vs 1.0 ± 0.18 kΩ, p > 0.05). An in vitro drug kinetics study revealed a faster release in the first 24 h (63.4 ± 0.6%) and a sustained release over the following 15 days (78.3 ± 1.7% in 2 days, 95.6 ± 1.0% in 7 days and 99.1 ± 0.4% in 14 days). The release rate was not affected by the drug, dose or the thickness of the coating. CONCLUSION: The dip-coating method is feasible for rapid casting of a drug-eluting PLGA film on an electrode array during CI surgery. The coated electrode array maintained its original morphology and became more hydrophilic. The loaded drug is released in a sustained manner and is easily regulated, and so the method might represent a potential application for clinical use in cochlear implantation.


Subject(s)
Cochlear Implants , Drug Carriers/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer/chemistry , Cochlear Implantation , Drug Liberation , Electrodes, Implanted , Silicon/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL