Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Anesthesiol ; 21(1): 22, 2021 01 20.
Article in English | MEDLINE | ID: mdl-33472587

ABSTRACT

BACKGROUND: Post-spinal anesthesia hypotension during cesarean delivery is caused by decreased systemic vascular resistance due to the blockage of the autonomic nerves, which is further worsened by inferior vena cava (IVC) compression by the gravid uterus. This study aimed to assess whether peak velocity and diameter of the IVC below the xiphoid or right common femoral vein (RCFV) in the inguinal region, as measured on ultrasound, could reflect the degree of IVC compression and further identify parturients at risk of post-spinal hypotension. METHODS: Fifty-six parturients who underwent elective cesarean section with spinal anesthesia were included in this study; peak velocities and anteroposterior diameters of the IVC and peak velocities and transverse diameters of the RCFV were measured using ultrasound before anesthesia. The primary outcome was the ultrasound measurements of IVC and RCFV acquired before spinal anesthesia and their association with post-spinal hypotension. Hypotension was defined as a drop in systolic arterial pressure by > 20% from the baseline. Multinomial logistic regression analysis was used to identify the association between the measurements of IVC, RCFV, and post-spinal hypotension during cesarean delivery. Receiver operating characteristic curves were used to test the abilities of the identified parameters to predict post-spinal hypotension; the areas under the curve and optimum cut-off values for the predictive parameters were calculated. RESULTS: A longer transverse diameter of the RCFV was associated with the occurrence of post-spinal hypotension (odds ratio = 2.022, 95% confidence interval [CI] 1.261-3.243). The area under the receiver operating characteristics curve for the prediction of post-spinal hypotension was 0.759 (95% CI 0.628-0.890, P = 0.001). A transverse diameter of > 12.2 mm of the RCFV could predict post-spinal hypotension during cesarean delivery. CONCLUSIONS: A longer transverse diameter of RCFV was associated with hypotension and could predict parturients at a major risk of hypotension before anesthesia. TRIAL REGISTRATION: This study was registered at http://www.chictr.org.cn on 16, May, 2018. No. ChiCTR1800016163 .


Subject(s)
Anesthesia, Spinal/methods , Cesarean Section , Femoral Vein/anatomy & histology , Hypotension/diagnosis , Intraoperative Complications/diagnosis , Preoperative Care/methods , Ultrasonography/methods , Adolescent , Adult , Anesthesia, Obstetrical , Female , Femoral Vein/diagnostic imaging , Humans , Hypotension/physiopathology , Intraoperative Complications/physiopathology , Predictive Value of Tests , Pregnancy , Risk Assessment , Supine Position , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...