Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 49(5): 3298-3313, 2022 May.
Article in English | MEDLINE | ID: mdl-35271742

ABSTRACT

PURPOSE: A novel phantom-imaging platform, a set of software tools, for automated and high-precision imaging of the American College of Radiology (ACR) positron emission tomography (PET) phantom for PET/magnetic resonance (PET/MR) and PET/computed tomography (PET/CT) systems is proposed. METHODS: The key feature of this platform is the vector graphics design that facilitates the automated measurement of the knife-edge response function and hence image resolution, using composite volume of interest templates in a 0.5 mm resolution grid applied to all inserts of the phantom. Furthermore, the proposed platform enables the generation of an accurate µ $\mu$ -map for PET/MR systems with a robust alignment based on two-stage image registration using specifically designed PET templates. The proposed platform is based on the open-source NiftyPET software package used to generate multiple list-mode data bootstrap realizations and image reconstructions to determine the precision of the two-stage registration and any image-derived statistics. For all the analyses, iterative image reconstruction was employed with and without modeled shift-invariant point spread function and with varying iterations of the ordered subsets expectation maximization (OSEM) algorithm. The impact of the activity outside the field of view (FOV) was assessed using two acquisitions of 30 min each, with and without the activity outside the FOV. RESULTS: The utility of the platform has been demonstrated by providing a standard and an advanced phantom analysis including the estimation of spatial resolution using all cylindrical inserts. In the imaging planes close to the edge of the axial FOV, we observed deterioration in the quantitative accuracy, reduced resolution (FWHM increased by 1-2 mm), reduced contrast, and background uniformity due to the activity outside the FOV. Although it slows convergence, the PSF reconstruction had a positive impact on resolution and contrast recovery, but the degree of improvement depended on the regions. The uncertainty analysis based on bootstrap resampling of raw PET data indicated high precision of the two-stage registration. CONCLUSIONS: We demonstrated that phantom imaging using the proposed methodology with the metric of spatial resolution and multiple bootstrap realizations may be helpful in more accurate evaluation of PET systems as well as in facilitating fine tuning for optimal imaging parameters in PET/MR and PET/CT clinical research studies.


Subject(s)
Positron Emission Tomography Computed Tomography , Positron-Emission Tomography , Algorithms , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Positron-Emission Tomography/methods , Software
2.
Eur J Nucl Med Mol Imaging ; 48(3): 747-756, 2021 03.
Article in English | MEDLINE | ID: mdl-32888039

ABSTRACT

PURPOSE: To determine thresholds for amyloid beta pathology and evaluate associations with longitudinal memory performance with the aim to identify a grey zone of early amyloid beta accumulation and investigate its clinical relevance. METHODS: We included 162 cognitively normal participants with subjective cognitive decline from the SCIENCe cohort (64 ± 8 years, 38% F, MMSE 29 ± 1). Each underwent a dynamic [18F] florbetapir PET scan, a T1-weighted MRI scan and longitudinal memory assessments (RAVLT delayed recall, n = 655 examinations). PET scans were visually assessed as amyloid positive/negative. Additionally, we calculated the mean binding potential (BPND) and standardized uptake value ratio (SUVr50-70) for an a priori defined composite region of interest. We determined six amyloid positivity thresholds using various data-driven methods (resulting thresholds: BPND 0.19/0.23/0.29; SUVr 1.28/1.34/1.43). We used Cohen's kappa to analyse concordance between thresholds and visual assessment. Next, we used quantiles to divide the sample into two to five subgroups of equal numbers (median, tertiles, quartiles, quintiles), and operationalized a grey zone as the range between the thresholds (0.19-0.29 BPND/1.28-1.43 SUVr). We used linear mixed models to determine associations between thresholds and memory slope. RESULTS: As determined by visual assessment, 24% of 162 individuals were amyloid positive. Concordance with visual assessment was comparable but slightly higher for BPND thresholds (range kappa 0.65-0.70 versus 0.60-0.63). All thresholds predicted memory decline (range beta - 0.29 to - 0.21, all p < 0.05). Analyses in subgroups showed memory slopes gradually became steeper with higher amyloid load (all p for trend < 0.05). Participants with a low amyloid burden benefited from a practice effect (i.e. increase in memory), whilst high amyloid burden was associated with memory decline. Memory slopes of individuals in the grey zone were intermediate. CONCLUSION: We provide evidence that not only high but also grey zone amyloid burden subtly impacts memory function. Therefore, in case a binary classification is required, we suggest using a relatively low threshold which includes grey zone amyloid pathology.


Subject(s)
Alzheimer Disease , Amyloid , Cognitive Dysfunction , Aged , Amyloid beta-Peptides , Aniline Compounds , Female , Humans , Male , Middle Aged , Positron-Emission Tomography
3.
J Pediatr Surg ; 33(4): 644-6, 1998 Apr.
Article in English | MEDLINE | ID: mdl-9574770

ABSTRACT

A 10-year-old boy presented with features of Cushing's syndrome. Investigations, including ultrasound scan and computed tomography scans, demonstrated a right adrenal tumor. The tumor was excised and histologically found to be an encapsulated adrenal adenoma. Surgical excision is the treatment of choice for adrenal tumors. However, because it is often difficult to differentiate benign from malignant lesions on histopathologic grounds, these patients need a regular long-term follow-up.


Subject(s)
Adrenal Cortex Neoplasms/complications , Adrenocortical Adenoma/complications , Cushing Syndrome/etiology , Child , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...