Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
J Glaucoma ; 25(12): 939-945, 2016 12.
Article in English | MEDLINE | ID: mdl-27820422

ABSTRACT

PURPOSE: The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension. MATERIALS AND METHODS: Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT. RESULTS: Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and Imax/Tavg ratio (P=0.023) and negative correlation with Smax/Navg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05). CONCLUSIONS: There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.


Subject(s)
Intraocular Pressure , Ocular Hypertension/diagnosis , Retinal Ganglion Cells/pathology , Tomography, Optical Coherence/methods , Visual Field Tests/methods , Visual Fields/physiology , Adult , Aged , Female , Humans , Male , Middle Aged , Nerve Fibers/pathology , Ocular Hypertension/physiopathology , Optic Disk/pathology , Tonometry, Ocular
3.
J Glaucoma ; 25(5): e559-61, 2016 05.
Article in English | MEDLINE | ID: mdl-26372158

ABSTRACT

PURPOSE: To investigate the significance of renal artery resistance and carotid intima media thickness (CIMT) parameters in patients with pseudoexfoliation syndrome (PES). MATERIALS AND METHODS: In this prospective case-control study, 37 patients were involved and grouped as PES (n=19) and control groups (n=18). Ophthalmological evaluation included visual acuity, intraocular pressure, central corneal thickness measurement, and optic disc evaluation. In addition, renal artery resistive index and CIMT measurements were taken for all patients and compared between the groups. RESULTS: The 2 groups were similar with respect to age, sex, and family history of glaucoma. The mean CIMT in the PES group was found to be significantly higher compared with the control group (0.73±0.02 vs. 0.59±0.06 mm, P=0.003). Renal artery resistive indices were found to be higher in the PES group than in the control group, however, the difference was not significant (P=0.46). A moderate positive correlation between CIMT and renal artery resistive indices was detected (r=0.447, P=0.01). However, a higher correlation rate was detected when the analysis was made in the PES group only (r=0.603, P=0.01). CONCLUSIONS: CIMT increases in PES patients and also the renal artery resistance index has a tendency to increase. Patients with PES should be informed about potential systemic consequences of this syndrome.


Subject(s)
Carotid Intima-Media Thickness , Elasticity/physiology , Exfoliation Syndrome/physiopathology , Glaucoma, Open-Angle/physiopathology , Renal Artery/physiology , Case-Control Studies , Female , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Prospective Studies , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...