Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Sci Pollut Res Int ; 27(12): 13315-13324, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32020456

ABSTRACT

The need for the sensing of environmental pollutants cannot be overemphasized in the twenty-first century. Herein, a sensor has been developed for the sensitive and selective detection of copper (Cu2+), lead (Pb2+) and cadmium (Cd2+) as major heavy metals polluting water environment. A screen-printed carbon electrode (SPCE) modified by fluorescent carbon dots (CDs) and gold nanoparticles (AuNPs) was successfully fabricated for sensing Cu2+, Pb2+ and Cd2+. Differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were deployed for the analysis of ternary analytes. CV was set at a potential range of - 0.8 to + 0.2 V at a scan rate of 100 mV/s, and DPV at a potential range of - 0.8 to + 0.1 V, scan rate of 50 mV/s, pulse rate of 0.2 V and pulse width of 50 ms. DPV technique was applied through the modified electrode for sensitive and selective determination of Cu2+, Pb2+ and Cd2+ at a concentration range of 0.01 to 0.27 ppm for Cu2+, Pb2+ and Cd2+. Tolerance for the highest possible concentration of foreign substances such as Mg2+, K+, Na+, NO3-, and SO42- was observed with a relative error less than ± 3%. The sensitivity of the modified electrode was at 0.17, 0.42 and 0.18 ppm for Cd2+, Pb2+ and Cu2+, respectively, while the limits of detection (LOD) achieved for cadmium, lead and copper were 0.0028, 0.0042 and 0.014 ppm, respectively. The quality of the modified electrode for sensing Cu2+, Pb2+ and Cd2+ at trace levels is in accordance with the World Health Organization (WHO) and Environmental Protection Agency (EPA) water regulation standard. The modified SPCE provides a cost-effective, dependable and stable means of detecting heavy metal ions (Cu2+, Pb2+ and Cd2+) in an aqueous solution. Graphical abstract .


Subject(s)
Manihot , Metal Nanoparticles , Cadmium , Carbon , Copper , Electrodes , Gold , Lead
2.
Chem Commun (Camb) ; 49(45): 5171-3, 2013 Jun 07.
Article in English | MEDLINE | ID: mdl-23628955

ABSTRACT

Aqueous based controlled decoration of platinum nanoparticles on plasma treated carbon nano-onions (CNOs) occurs within the shear flow generated by a vortex fluidic device (VFD), using ascorbic acid as the reducing agent, with the electrocatalytic potential of the resulting Pt-NPs@CNOs nano-composites demonstrated.

3.
Chem Commun (Camb) ; 49(42): 4845-7, 2013 May 25.
Article in English | MEDLINE | ID: mdl-23598776

ABSTRACT

Pyrene-conjugated hyaluronan (Py-HA) facilitates the exfoliation of low-dimensional nanomaterials including graphite, hexagonal boron nitride (h-BN) and molybdenum disulfide (MoS2), and the dispersion of carbon nanotubes (CNTs) and carbon nano-onions (CNOs) in water (and PBS solutions), with the assistance of sonication.

4.
Chem Commun (Camb) ; 48(81): 10102-4, 2012 Oct 18.
Article in English | MEDLINE | ID: mdl-22957341

ABSTRACT

Size selective growth of palladium nano-particles 2-7 nm in diameter on the surface of carbon nano-onions (CNOs) (derived from catalytic cracking of methane) in water involves pretreating the CNOs with p-phosphonic acid calix[8]arene then H(2)PdCl(4) followed by dynamic thin film processing under hydrogen in a vortex fluidic device.


Subject(s)
Carbon/chemistry , Nanostructures/chemistry , Palladium/chemistry , Calixarenes/chemistry , Methane/chemistry , Microfluidic Analytical Techniques , Nanostructures/ultrastructure , Particle Size , Phosphorous Acids/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...