1.
Chronobiol Int ; 40(6): 759-768, 2023 06 03.
Article in English | MEDLINE | ID: mdl-37144470

ABSTRACT

Intensive care units (ICUs) may disrupt sleep. Quantitative ICU studies of concurrent and continuous sound and light levels and timings remain sparse in part due to the lack of ICU equipment that monitors sound and light. Here, we describe sound and light levels across three adult ICUs in a large urban United States tertiary care hospital using a novel sensor. The novel sound and light sensor is composed of a Gravity Sound Level Meter for sound level measurements and an Adafruit TSL2561 digital luminosity sensor for light levels. Sound and light levels were continuously monitored in the room of 136 patients (mean age = 67.0 (8.7) years, 44.9% female) enrolled in the Investigation of Sleep in the Intensive Care Unit study (ICU-SLEEP; Clinicaltrials.gov: #NCT03355053), at the Massachusetts General Hospital. The hours of available sound and light data ranged from 24.0 to 72.2 hours. Average sound and light levels oscillated throughout the day and night. On average, the loudest hour was 17:00 and the quietest hour was 02:00. Average light levels were brightest at 09:00 and dimmest at 04:00. For all participants, average nightly sound levels exceeded the WHO guideline of < 35 decibels. Similarly, mean nightly light levels varied across participants (minimum: 1.00 lux, maximum: 577.05 lux). Sound and light events were more frequent between 08:00 and 20:00 than between 20:00 and 08:00 and were largely similar on weekdays and weekend days. Peaks in distinct alarm frequencies (Alarm 1) occurred at 01:00, 06:00, and at 20:00. Alarms at other frequencies (Alarm 2) were relatively consistent throughout the day and night, with a small peak at 20:00. In conclusion, we present a sound and light data collection method and results from a cohort of critically ill patients, demonstrating excess sound and light levels across multiple ICUs in a large tertiary care hospital in the United States. ClinicalTrials.gov, #NCT03355053. Registered 28 November 2017, https://clinicaltrials.gov/ct2/show/NCT03355053.


Subject(s)
Circadian Rhythm , Intensive Care Units , Adult , Aged , Female , Humans , Male , Middle Aged , Hospitals, Urban , Noise , Sleep , United States
2.
Front Netw Physiol ; 3: 1120390, 2023.
Article in English | MEDLINE | ID: mdl-36926545

ABSTRACT

Introduction: To measure sleep in the intensive care unit (ICU), full polysomnography is impractical, while activity monitoring and subjective assessments are severely confounded. However, sleep is an intensely networked state, and reflected in numerous signals. Here, we explore the feasibility of estimating conventional sleep indices in the ICU with heart rate variability (HRV) and respiration signals using artificial intelligence methods Methods: We used deep learning models to stage sleep with HRV (through electrocardiogram) and respiratory effort (through a wearable belt) signals in critically ill adult patients admitted to surgical and medical ICUs, and in age and sex-matched sleep laboratory patients Results: We studied 102 adult patients in the ICU across multiple days and nights, and 220 patients in a clinical sleep laboratory. We found that sleep stages predicted by HRV- and breathing-based models showed agreement in 60% of the ICU data and in 81% of the sleep laboratory data. In the ICU, deep NREM (N2 + N3) proportion of total sleep duration was reduced (ICU 39%, sleep laboratory 57%, p < 0.01), REM proportion showed heavy-tailed distribution, and the number of wake transitions per hour of sleep (median 3.6) was comparable to sleep laboratory patients with sleep-disordered breathing (median 3.9). Sleep in the ICU was also fragmented, with 38% of sleep occurring during daytime hours. Finally, patients in the ICU showed faster and less variable breathing patterns compared to sleep laboratory patients Conclusion: The cardiovascular and respiratory networks encode sleep state information, which, together with artificial intelligence methods, can be utilized to measure sleep state in the ICU.

3.
Sleep Breath ; 27(3): 1013-1026, 2023 06.
Article in English | MEDLINE | ID: mdl-35971023

ABSTRACT

PURPOSE: Sleep-disordered breathing may be induced by, exacerbate, or complicate recovery from critical illness. Disordered breathing during sleep, which itself is often fragmented, can go unrecognized in the intensive care unit (ICU). The objective of this study was to investigate the prevalence, severity, and risk factors of sleep-disordered breathing in ICU patients using a single respiratory belt and oxygen saturation signals. METHODS: Patients in three ICUs at Massachusetts General Hospital wore a thoracic respiratory effort belt as part of a clinical trial for up to 7 days and nights. Using a previously developed machine learning algorithm, we processed respiratory and oximetry signals to measure the 3% apnea-hypopnea index (AHI) and estimate AH-specific hypoxic burden and periodic breathing. We trained models to predict AHI categories for 12-h segments from risk factors, including admission variables and bio-signals data, available at the start of these segments. RESULTS: Of 129 patients, 68% had an AHI ≥ 5; 40% an AHI > 15, and 19% had an AHI > 30 while critically ill. Median [interquartile range] hypoxic burden was 2.8 [0.5, 9.8] at night and 4.2 [1.0, 13.7] %min/h during the day. Of patients with AHI ≥ 5, 26% had periodic breathing. Performance of predicting AHI-categories from risk factors was poor. CONCLUSIONS: Sleep-disordered breathing and sleep apnea events while in the ICU are common and are associated with substantial burden of hypoxia and periodic breathing. Detection is feasible using limited bio-signals, such as respiratory effort and SpO2 signals, while risk factors were insufficient to predict AHI severity.


Subject(s)
Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Humans , Sleep Apnea, Obstructive/diagnosis , Cross-Sectional Studies , Prevalence , Polysomnography , Sleep Apnea Syndromes/diagnosis , Sleep Apnea Syndromes/epidemiology , Hypoxia/complications , Intensive Care Units
4.
Sleep ; 46(3)2023 03 09.
Article in English | MEDLINE | ID: mdl-36448766

ABSTRACT

STUDY OBJECTIVES: Dementia is a growing cause of disability and loss of independence in the elderly, yet remains largely underdiagnosed. Early detection and classification of dementia can help close this diagnostic gap and improve management of disease progression. Altered oscillations in brain activity during sleep are an early feature of neurodegenerative diseases and be used to identify those on the verge of cognitive decline. METHODS: Our observational cross-sectional study used a clinical dataset of 10 784 polysomnography from 8044 participants. Sleep macro- and micro-structural features were extracted from the electroencephalogram (EEG). Microstructural features were engineered from spectral band powers, EEG coherence, spindle, and slow oscillations. Participants were classified as dementia (DEM), mild cognitive impairment (MCI), or cognitively normal (CN) based on clinical diagnosis, Montreal Cognitive Assessment, Mini-Mental State Exam scores, clinical dementia rating, and prescribed medications. We trained logistic regression, support vector machine, and random forest models to classify patients into DEM, MCI, and CN groups. RESULTS: For discriminating DEM versus CN, the best model achieved an area under receiver operating characteristic curve (AUROC) of 0.78 and area under precision-recall curve (AUPRC) of 0.22. For discriminating MCI versus CN, the best model achieved an AUROC of 0.73 and AUPRC of 0.18. For discriminating DEM or MCI versus CN, the best model achieved an AUROC of 0.76 and AUPRC of 0.32. CONCLUSIONS: Our dementia classification algorithms show promise for incorporating dementia screening techniques using routine sleep EEG. The findings strengthen the concept of sleep as a window into neurodegenerative diseases.


Subject(s)
Alzheimer Disease , Cognitive Dysfunction , Dementia , Humans , Aged , Dementia/diagnosis , Cross-Sectional Studies , Cognitive Dysfunction/diagnosis , Cognitive Dysfunction/psychology , Sleep , Brain
5.
Sleep ; 45(4)2022 04 11.
Article in English | MEDLINE | ID: mdl-34984446

ABSTRACT

STUDY OBJECTIVES: Alterations in sleep spindles have been linked to cognitive impairment. This finding has contributed to a growing interest in identifying sleep-based biomarkers of cognition and neurodegeneration, including sleep spindles. However, flexibility surrounding spindle definitions and algorithm parameter settings present a methodological challenge. The aim of this study was to characterize how spindle detection parameter settings influence the association between spindle features and cognition and to identify parameters with the strongest association with cognition. METHODS: Adult patients (n = 167, 49 ± 18 years) completed the NIH Toolbox Cognition Battery after undergoing overnight diagnostic polysomnography recordings for suspected sleep disorders. We explored 1000 combinations across seven parameters in Luna, an open-source spindle detector, and used four features of detected spindles (amplitude, density, duration, and peak frequency) to fit linear multiple regression models to predict cognitive scores. RESULTS: Spindle features (amplitude, density, duration, and mean frequency) were associated with the ability to predict raw fluid cognition scores (r = 0.503) and age-adjusted fluid cognition scores (r = 0.315) with the best spindle parameters. Fast spindle features generally showed better performance relative to slow spindle features. Spindle features weakly predicted total cognition and poorly predicted crystallized cognition regardless of parameter settings. CONCLUSIONS: Our exploration of spindle detection parameters identified optimal parameters for studies of fluid cognition and revealed the role of parameter interactions for both slow and fast spindles. Our findings support sleep spindles as a sleep-based biomarker of fluid cognition.


Subject(s)
Electroencephalography , Sleep Wake Disorders , Adult , Cognition , Humans , Polysomnography , Sleep , Sleep Stages
6.
Sleep Breath ; 26(3): 1033-1044, 2022 09.
Article in English | MEDLINE | ID: mdl-34409545

ABSTRACT

OBJECTIVE: Sleep-related respiratory abnormalities are typically detected using polysomnography. There is a need in general medicine and critical care for a more convenient method to detect sleep apnea automatically from a simple, easy-to-wear device. The objective was to detect abnormal respiration and estimate the Apnea-Hypopnea Index (AHI) automatically with a wearable respiratory device with and without SpO2 signals using a large (n = 412) dataset serving as ground truth. DESIGN: Simultaneously recorded polysomnography (PSG) and wearable respiratory effort data were used to train and evaluate models in a cross-validation fashion. Time domain and complexity features were extracted, important features were identified, and a random forest model was employed to detect events and predict AHI. Four models were trained: one each using the respiratory features only, a feature from the SpO2 (%)-signal only, and two additional models that use the respiratory features and the SpO2 (%) feature, one allowing a time lag of 30 s between the two signals. RESULTS: Event-based classification resulted in areas under the receiver operating characteristic curves of 0.94, 0.86, and 0.82, and areas under the precision-recall curves of 0.48, 0.32, and 0.51 for the models using respiration and SpO2, respiration-only, and SpO2-only, respectively. Correlation between expert-labelled and predicted AHI was 0.96, 0.78, and 0.93, respectively. CONCLUSIONS: A wearable respiratory effort signal with or without SpO2 signal predicted AHI accurately, and best performance was achieved with using both signals.


Subject(s)
Sleep Apnea Syndromes , Wearable Electronic Devices , Humans , Oxygen , Oxygen Saturation , Polysomnography , Respiratory Rate
SELECTION OF CITATIONS
SEARCH DETAIL
...