Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
2.
Diagnostics (Basel) ; 13(18)2023 Sep 13.
Article in English | MEDLINE | ID: mdl-37761299

ABSTRACT

BACKGROUND: Rural general practitioners (GPs) have insufficient diagnostic information to deal with complex clinical scenarios due to the inequality in medical imaging resources in rural and remote communities. The objective of this study is to explore the value of a tele-mentored handheld ultrasound (tele-HHUS) system, allowing GPs to provide ultrasound (US) services in rural and remote communities. METHODS: Overall, 708 patients underwent tele-HHUS examination between March and October 2021 and March and April 2022 across thirteen primary hospitals and two tertiary-care general hospitals. All US examinations were guided and supervised remotely in real time by US experts more than 300 km away using the tele-HHUS system. The following details were recorded: location of tele-HHUS scanning, primary complaints, clinical diagnosis, and US findings. The recommendations (referral or follow-up) based on clinical experience alone were compared with those based on clinical experience with tele-HHUS information. RESULTS: Tele-HHUS examinations were performed both in hospital settings (90.6%, 642/708) and out of hospital settings (9.4%, 66/708). Leaving aside routine physical examinations, flank pain (14.2%, 91/642) was the most common complaint in inpatients, while chest distress (12.1%, 8/66) and flank discomfort (12.1%, 8/66) were the most common complaints in out-of-hospital settings. Additionally, the referral rate increased from 5.9% to 8.3% (kappa = 0.202; p = 0.000). CONCLUSIONS: The tele-HHUS system can help rural GPs perform HHUS successfully in remote and rural communities. This novel mobile telemedicine model is valuable in resource-limited areas.

3.
Front Public Health ; 10: 915071, 2022.
Article in English | MEDLINE | ID: mdl-35923952

ABSTRACT

Background: Disability has become a global population health challenge. Due to difficulties in self-care or independent living, patients with disability mainly live in community-based care centers or institutions for long-term care. Nonetheless, these settings often lack basic medical resources, such as ultrasonography. Thus, remote ultrasonic robot technology for clinical applications across wide regions is imperative. To date, few experiences of remote diagnostic systems in rural care centers have been reported. Objective: To assess the feasibility of a fifth-generation cellular technology (5G)-based robot-assisted remote ultrasound system in a care center for disabled patients in rural China. Methods: Patients underwent remote robot-assisted and bedside ultrasound examinations of the liver, gallbladder, spleen, and kidneys. We compared the diagnostic consistency and differences between the two modalities and evaluated the examination duration, image quality, and safety. Results: Forty-nine patients were included (21 men; mean age: 61.0 ± 19.0 [range: 19-91] years). Thirty-nine and ten had positive and negative results, respectively; 67 lesions were detected. Comparing the methods, 41 and 8 patients had consistent and inconsistent diagnoses, respectively. The McNemar and kappa values were 0.727 and 0.601, respectively. The mean duration of remote and bedside examinations was 12.2 ± 4.5 (range: 5-26) min and 7.5 ± 1.8 (range: 5-13) min (p < 0.001), respectively. The median image score for original images on the patient side and transmitted images on the doctor side was 5 points (interquartile range: [IQR]: 4.7-5.0) and 4.7 points (IQR: 4.5-5.0) (p = 0.176), respectively. No obvious complications from the examination were reported. Conclusions: A 5G-based robot-assisted remote ultrasound system is feasible and has comparable diagnostic efficiency to traditional bedside ultrasound. This system may provide a unique solution for basic ultrasound diagnostic services in primary healthcare settings.


Subject(s)
Disabled Persons , Robotics , Adult , Aged , Aged, 80 and over , China , Humans , Male , Middle Aged , Robotics/methods , Rural Population , Ultrasonography/methods
4.
Korean J Radiol ; 23(5): 555-565, 2022 05.
Article in English | MEDLINE | ID: mdl-35506529

ABSTRACT

OBJECTIVE: To assess the efficacy and safety of ultrasound (US)-guided radiofrequency ablation (RFA) in patients with primary hyperparathyroidism (PHPT). MATERIALS AND METHODS: This prospective study enrolled 39 participants (14 male, 25 female; mean age, 59.5 ± 15.3 [range, 18-87] years) between September 1, 2018, and January 31, 2021. All participants had parathyroid lesions causing PHPT, proven biochemically and through imaging. The imaging features of the PHPT nodules, including the shape, margin, size, composition, and location, were evaluated before treatment. Serum intact parathyroid hormone, calcium, and phosphorus levels; parathyroid nodule volume; and PHPT-related symptoms were recorded before and after treatment. We calculated the technical success, biochemical cure, and clinical cure rates for these patients. Complications were evaluated during and after the ablation. RESULTS: Complete ablation was achieved in 38 of the 39 nodules in the 39 enrolled participants. All the patients were treated in one session. The technical success rate was 97.4% (38/39). The mean follow-up duration was 13.2 ± 4.6 (range, 6.0-24.9) months. At 6 and 12 months post-RFA, the biochemical cure rates were 82.1% (32/39) and 84.4% (27/32), respectively, and the clinical cure rates were 100% (39/39) and 96.9% (31/32), respectively. Only 2.6% (1/39) of the patients had recurrent PHPT. At 1, 3, 6, and 12 months after technically successful RFA, 44.7% (17/38), 34.3% (12/35), 15.8% (6/38), and 12.5% (4/32) of participants, respectively, had elevated eucalcemic parathyroid hormone levels. Recurrent laryngeal nerve paralysis occurred in 5.1% (2/39) of the patients, who recovered spontaneously within 1-3 months. CONCLUSION: US-guided RFA was effective and safe for PHPT patients. RFA may be an alternative treatment tool for patients who cannot tolerate or refuse to undergo surgery.


Subject(s)
Hyperparathyroidism, Primary , Radiofrequency Ablation , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Hyperparathyroidism, Primary/diagnostic imaging , Hyperparathyroidism, Primary/surgery , Male , Middle Aged , Parathyroid Hormone , Prospective Studies , Radiofrequency Ablation/methods , Retrospective Studies , Treatment Outcome , Ultrasonography, Interventional , Young Adult
6.
J Ultrasound Med ; 40(2): 385-390, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32725833

ABSTRACT

To date, coronavirus disease 2019 (COVID-19) has infected millions of people worldwide. Ultrasound plays an indispensable role in the diagnosis, monitoring, and follow-up of patients with COVID-19. In this study, we used a robotic tele-echography system based on a 5G communication network for remote diagnosis. The system has great potential for lung, heart, and vasculature information, medical staff protection, and resource sharing, can be a valuable tool for treating patients during the pandemic, and can be expected to expand to more specialized fields.


Subject(s)
COVID-19/complications , Robotics/methods , Telemedicine/methods , Ultrasonography/methods , Venous Thrombosis/diagnostic imaging , Venous Thrombosis/etiology , Aged, 80 and over , Disease Progression , Heart/diagnostic imaging , Humans , Lower Extremity/diagnostic imaging , Lung/diagnostic imaging , Male , Quarantine/methods , SARS-CoV-2 , Telemedicine/instrumentation , Ultrasonography/instrumentation
7.
Chest ; 159(1): 270-281, 2021 01.
Article in English | MEDLINE | ID: mdl-32653568

ABSTRACT

BACKGROUND: Traditional methods for cardiopulmonary assessment of patients with coronavirus disease 2019 (COVID-19) pose risks to both patients and examiners. This necessitates a remote examination of such patients without sacrificing information quality. RESEARCH QUESTION: The goal of this study was to assess the feasibility of a 5G-based robot-assisted remote ultrasound system in examining patients with COVID-19 and to establish an examination protocol for telerobotic ultrasound scanning. STUDY DESIGN AND METHODS: Twenty-three patients with COVID-19 were included and divided into two groups. Twelve were nonsevere cases, and 11 were severe cases. All patients underwent a 5G-based robot-assisted remote ultrasound system examination of the lungs and heart following an established protocol. Distribution characteristics and morphology of the lung and surrounding tissue lesions, left ventricular ejection fraction, ventricular area ratio, pericardial effusion, and examination-related complications were recorded. Bilateral lung lesions were evaluated by using a lung ultrasound score. RESULTS: The remote ultrasound system successfully and safely performed cardiopulmonary examinations of all patients. Peripheral lung lesions were clearly evaluated. Severe cases of COVID-19 had significantly more diseased regions (median [interquartile range], 6.0 [2.0-11.0] vs 1.0 [0.0-2.8]) and higher lung ultrasound scores (12.0 [4.0-24.0] vs 2.0 [0.0-4.0]) than nonsevere cases of COVID-19 (both, P < .05). One nonsevere case (8.3%; 95% CI, 1.5-35.4) and three severe cases (27.3%; 95% CI, 9.7-56.6) were complicated by pleural effusions. Four severe cases (36.4%; 95% CI, 15.2-64.6) were complicated by pericardial effusions (vs 0% of nonsevere cases, P < .05). No patients had significant examination-related complications. INTERPRETATION: Use of the 5G-based robot-assisted remote ultrasound system is feasible and effectively obtains ultrasound characteristics for cardiopulmonary assessment of patients with COVID-19. By following established protocols and considering medical history, clinical manifestations, and laboratory markers, this system might help to evaluate the severity of COVID-19 remotely.


Subject(s)
COVID-19/complications , Heart Diseases/diagnostic imaging , Heart Diseases/etiology , Lung Diseases/diagnostic imaging , Lung Diseases/etiology , Robotics , Adult , Aged , Aged, 80 and over , Feasibility Studies , Female , Humans , Male , Middle Aged , Retrospective Studies , Ultrasonography/methods
8.
Article in English | MEDLINE | ID: mdl-32881685

ABSTRACT

Early diagnosis is critical for the prevention and control of the coronavirus disease 2019 (COVID-19). We attempted to apply a protocol using teleultrasound, which is supported by the 5G network, to explore the feasibility of solving the problem of early imaging assessment of COVID-19. Four male patients with confirmed or suspected COVID-19 were hospitalized in isolation wards in two different cities. Ultrasound specialists, located in two other different cities, carried out the robot-assisted teleultrasound and remote consultation in order to settle the problem of early cardiopulmonary evaluation. Lung ultrasound, brief echocardiography, and blood volume assessment were performed. Whenever difficulties of remote manipulation and diagnosis occurred, the alternative examination was repeated by a specialist from another city, and in sequence, remote consultation was conducted immediately to meet the consensus. The ultrasound specialists successfully completed the telerobotic ultrasound. Lung ultrasound indicated signs of pneumonia with varying degrees in all cases and mild pleural effusion in one case. No abnormalities of cardiac structure and function and blood volume were detected. Remote consultation on the issue of manipulation practice, and the diagnosis in one case was conducted. The cardiopulmonary information was delivered to the frontline clinicians immediately for further treatment. The practice of teleultrasound protocol makes early diagnosis and repeated assessment available in the isolation ward. Ultrasound specialists can be protected from infection, and personal protective equipment can be spared. Quality control can be ensured by remote consultations among doctors. This protocol is worth consideration as a feasible strategy for early imaging assessment in the COVID-19 pandemic.


Subject(s)
Coronavirus Infections/diagnostic imaging , Pneumonia, Viral/diagnostic imaging , Robotics/methods , Telemedicine/methods , Ultrasonography/methods , Betacoronavirus , COVID-19 , Early Diagnosis , Equipment Design , Humans , Male , Pandemics , Pilot Projects , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...