Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
Comput Methods Biomech Biomed Engin ; 23(13): 1034-1040, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32619356

ABSTRACT

This study aimed to investigate the effect of miniscrews thread shape on the stress distribution receiving a torque load. Seven thread shapes (S,V1,V2,B1,B2,R1,R2) models were constructed and a 6 Nmm-torque load was applied. The order of maximum equivalent stress (EQV) value was V1 > V2 > B1 > R1 > R2 > B2 > S. The order of maximum displacement of miniscrew (Max DM) value was S > B2 > R1 = V1 > B1 > V2 > R2. Model R2 may be the most appropriate thread shape affording a torque force.


Subject(s)
Bone Screws , Finite Element Analysis , Orthodontic Appliance Design , Stress, Mechanical , Torque , Biomechanical Phenomena , Cortical Bone/pathology , Dental Stress Analysis , Humans
2.
Neuroreport ; 30(5): 331-337, 2019 03 20.
Article in English | MEDLINE | ID: mdl-30822282

ABSTRACT

Pruritus is one of the common side effects of intrathecal or epidural injection of opioids. The aim of this study was to test the antipruritic effect of acupuncture and its possible mechanism. We used electroacupuncture (EA), toll-like receptor (TLR)2/4 antagonist sparstolonin B (SsnB), and TLR2/4 agonist peptidoglycan (PGN) to precondition female wild-type BALB/c mice, and then prepared a morphine-induced pruritus model. The mRNA and protein expression levels of TLR2, TLR4, MyD88, and NF-κB were detected by RT-PCR and western blotting. The contents of interleukin (IL)-1, IL-6, IL-12, IL-10, and tumor necrosis factor-α in serum were measured by ELISA assays. Flow cytometry was performed to analyze the ratio of M1-phenotype to M2-phenotype macrophages. Our results showed that EA preconditioning improved pruritus; reduced the expressions of TLR2, TLR4, MyD88, and NF-κB both at the mRNA and protein levels (P<0.05); reduced the expression of proinflammatory cytokines IL-1, IL-6, IL-12, and tumor necrosis factor-α; and increased the expression of anti-inflammatory cytokine IL-10 (P<0.05). EA promoted M2-phenotype macrophage differentiation. Moreover, these results showed no significant difference between the SsnB group and the EA+SsnB group (P>0.05), but showed a significant difference between the PGN group and the EA+PGN group (P<0.05). Therefore, we propose that EA may be involved in the remission of pruritus in morphine-induced pruritus model mice through the TLR2/4-MyD88-NF-κB pathway. EA is a potential therapeutic treatment for pruritus.


Subject(s)
Analgesics, Opioid/toxicity , Electroacupuncture , Morphine/toxicity , Pruritus/chemically induced , Pruritus/metabolism , Animals , Disease Models, Animal , Female , Mice , Mice, Inbred BALB C , Myeloid Differentiation Factor 88/metabolism , NF-kappa B/metabolism , Signal Transduction/physiology , Toll-Like Receptor 2/metabolism
3.
PLoS One ; 10(12): e0144744, 2015.
Article in English | MEDLINE | ID: mdl-26659581

ABSTRACT

BACKGROUND: Stress on the bone surrounding dental micro-implants affects implant success. PURPOSE: To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. MATERIALS AND METHODS: Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. RESULTS: The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. CONCLUSION: When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm.


Subject(s)
Dental Implants , Dental Stress Analysis , Finite Element Analysis , Models, Anatomic , Biomechanical Phenomena , Compressive Strength , Dental Prosthesis Design , Humans , Mandible/anatomy & histology , Mandible/surgery , Maxilla/anatomy & histology , Maxilla/surgery , Stress, Mechanical , Torque
4.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 48(1): 37-40, 2013 Jan.
Article in Chinese | MEDLINE | ID: mdl-23534520

ABSTRACT

OBJECTIVE: To investigate the influence of the diameter and length of the mini-implant on the primary stability after loading with composite forces (CF) which contained torque and horizontal forces (HF). METHODS: Ninety-six finite element models were established by the combination of mini-implant and bone, diameters (1.2 mm, 1.6 mm, 2.0 mm) and length (6 mm, 8 mm, 10 mm, 12 mm). There were 12 sizes, each size corresponded with 8 models. Group HF (each size n = 4) was loaded with 1.96 N horizontal force and Group CF (each size n = 4) was loaded with composite force which contained 6 N·mm torque and 1.96 N horizontal force. The maximum displacement of mini-implant with different force directions, implant diameters and lengths were evaluated. RESULTS: The effect of force direction on the displacement related to diameter of mini-implant. The maximum displacement under load with HF respectively was changed with the changing of diameter[1.2 mm: (7.71 ± 0.49) µm; 1.6 mm: (3.94 ± 0.31) µm; 2.0 mm: (2.32 ± 0.43) µm], which were smaller than the maximum displacement of Group CF [1.2 mm: (9.22 ± 0.63) µm; 1.6 mm: (4.62 ± 0.52) µm; 2.0 mm: (2.69 ± 0.49) µm] (P < 0.05). When diameter was 1.2 mm, the difference of the maximum displacement [(1.61 ± 0.22) µm] between Group HF and CF was more obvious than that when the diameter was 1.6 mm or 2.0 mm [(0.64 ± 0.12), (0.49 ± 0.06) µm] (P < 0.05). CONCLUSIONS: The composite force had unfavorable effect on the primary stability of the mini-implant. The diameter of the mini-implant had better be larger than 1.2 mm when the composite forces were applied.


Subject(s)
Finite Element Analysis , Orthodontic Anchorage Procedures/instrumentation , Torque
5.
Article in English | MEDLINE | ID: mdl-19748293

ABSTRACT

OBJECTIVE: We compared the anesthetic efficacy of inferior alveolar nerve block (IANB) plus buccal infiltration (BI) and IANB plus periodontal ligament (PDL) articaine injections in patients with irreversible pulpitis in the mandibular first molar. STUDY DESIGN: Fifty-seven volunteers, patients with irreversible pulpitis in the mandibular first molar admitted to the Department of Stomatology, Second Affiliated Hospital, Sun Yat-Sen University, randomly received conventional IANB, containing 1.7 mL 4% articaine/HCl with 1:100,000 epinephrine, plus either BI or PDL injections containing 0.4 mL articaine/HCl with 1:100,000 epinephrine. The patients recorded the pain of the injections and endodontic access on a Heft-Parker visual analog scale (VAS). RESULTS: According to the VAS scores, all patients experienced no or mild pain with BI and PDL injections after the application of IANB. Anesthetic success occurred in 81.48% for IANB plus BI (IANB/BI) compared with 83.33% for IANB plus PDL injection (IANB/PDL injection). None of the observed differences between the 2 groups was significant (P > .05). CONCLUSION: Both injection combinations resulted in high anesthetic success in patients with irreversible pulpitis in the mandibular first molar.


Subject(s)
Anesthesia, Dental/methods , Anesthesia, Local/methods , Anesthetics, Local/administration & dosage , Nerve Block/methods , Pulpitis/therapy , Adolescent , Adult , Carticaine/administration & dosage , Cheek , Female , Humans , Injections , Male , Mandible , Mandibular Nerve , Middle Aged , Molar , Pain Measurement , Periodontal Ligament , Young Adult
6.
Ann Plast Surg ; 62(2): 154-7, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19158525

ABSTRACT

Mucous membrane hemangiomas of the lip are common benign vascular tumors of infancy. This clinical study evaluated the efficacy and safety of liquid nitrogen cryotherapy of mucous membrane hemangiomas of the lip in early infancy. It was a retrospective review of 127 pediatric patients with hemangiomas involving the lips who underwent liquid nitrogen cryotherapy under inhalation general anesthesia with sevoflurane. Forty-one males and 86 females were treated. The overall median age at diagnosis of the mucous membrane hemangiomas was 3.6 months (range, 7 days to 18 months). The oral mucous membrane hemangioma involved the vermilion of the lower lip in 78 cases (61.4%), the vermilion of the upper lip in 40 cases (31.5%), and both vermilions in 9 cases (7.1%). No complications because of anesthesia occurred. The mean follow-up was 10 months, with a range of 8 to 14 months; 94 lesions (74.0%) were completely involuted, 22 lesions (17.3%) were mostly involuted, 11 lesions (8.7%) were partially involuted, and no lesion showed a small amount of involution. Liquid nitrogen cryotherapy is an effective, simple, and safe treatment for mucous membrane hemangiomas of the lip in early infancy.


Subject(s)
Anesthesia, Inhalation , Anesthetics, Inhalation/administration & dosage , Cryotherapy/methods , Hemangioma/surgery , Lip Neoplasms/surgery , Methyl Ethers/administration & dosage , Mouth Mucosa , Female , Humans , Infant , Infant, Newborn , Male , Nitrogen , Retrospective Studies , Sevoflurane
SELECTION OF CITATIONS
SEARCH DETAIL
...