Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Anesthesiol ; 24(1): 201, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38844869

ABSTRACT

BACKGROUND: Significant hemodynamic changes occur during liver transplantation, emphasizing the importance of precious and continuous monitoring of cardiac output, cardiac index, and other parameters. Although the monitoring of cardiac output by pulse indicator continuous cardiac output (PiCCO) was statistically homogeneous compared to the clinical gold standard pulmonary artery catheterization (PAC) in previous studies of liver transplantation, there are fewer statistical methods for the assessment of its conclusions, and a lack of comparisons of other hemodynamic parameters (e.g., SVRI, systemic vascular resistance index). Some studies have also concluded that the agreement between PiCCO and PAC is not good enough. Overall, there are no uniform conclusions regarding the agreement between PiCCO and PAC in previous studies. This study evaluates the agreement and trending ability of relevant hemodynamic parameters obtained with PiCCO compared to the clinical gold standard PAC from multiple perspectives, employing various statistical methods. METHODS: Fifty-two liver transplantation patients were included. Cardiac output (CO), cardiac index (CI), SVRI and stroke volume index (SVI) values were monitored at eight time points using both PiCCO and PAC. The results were analyzed by Bland-Altman analysis, Passing-bablok regression, intra-class correlation coefficient (ICC), 4-quadrant plot, polar plot, and trend interchangeability method (TIM). RESULTS: The Bland-Altman analysis revealed high percentage errors for PiCCO: 54.06% for CO, 52.70% for CI, 62.18% for SVRI, and 51.97% for SVI, indicating poor accuracy. While Passing-Bablok plots showed favorable agreement for SVRI overall and during various phases, the agreement for other parameters was less satisfactory. The ICC results confirmed good overall agreement between the two devices across most parameters, except for SVRI during the new liver phase, which showed poor agreement. Additionally, four-quadrant and polar plot analyses indicated that all agreement rate values fell below the clinically acceptable threshold of over 90%, and all angular deviation values exceeded ± 5°, demonstrating that PiCCO is unable to meet the acceptable trends. Using the TIM, the interchangeability rates were found to be quite low: 20% for CO and CI, 16% for SVRI, and 13% for SVI. CONCLUSIONS: Our study revealed notable disparities in absolute values of CO, CI, SVRI and SVI between PiCCO and PAC in intraoperative liver transplant settings, notably during the neohepatic phase where errors were particularly pronounced. Consequently, these findings highlight the need for careful consideration of PiCCO's advantages and disadvantages in liver transplantation scenarios, including its multiple parameters (such as the encompassing extravascular lung water index), against its limited correlation with PAC.


Subject(s)
Cardiac Output , Catheterization, Swan-Ganz , Hemodynamics , Liver Transplantation , Monitoring, Intraoperative , Liver Transplantation/methods , Humans , Catheterization, Swan-Ganz/methods , Cardiac Output/physiology , Male , Middle Aged , Female , Hemodynamics/physiology , Monitoring, Intraoperative/methods , Aged , Adult , Pulmonary Artery/physiology
2.
Ophthalmic Plast Reconstr Surg ; 39(3): 260-265, 2023.
Article in English | MEDLINE | ID: mdl-36727809

ABSTRACT

PURPOSE: To evaluate the effect of either flurbiprofen axetil or nalbuphine combined with retrobulbar block (RB) before surgery on postoperative pain control and enhanced recovery in day-care patients undergoing orbital implantation. METHODS: A total of 45 patients undergoing orbital implantation with general anesthesia were randomly divided into three groups: flurbiprofen axetil (1 mg/kg) combined with RB (group F), nalbuphine (0.1 mg/kg) combined with RB (group N), and placebo as normal saline with RB (group C). The primary outcome was the average pain score (numeric rating scale: 0-10) within the first 24 hours. Other outcomes including the peak pain score, paracetamol requirement, quality of recovery (QoR)-15, and adverse effects (AEs) were assessed. RESULTS: The average and peak pain scores within 24 hours after surgery in group F were significantly lower than in other groups ( p < 0.0167). Compared with group C, the NRS scores were significantly decreased at 2 and 4 hours in group F, and 2 hours in group N after surgery ( p < 0.0167), but without significant differences at other measured time points. The time to first paracetamol oral intake displayed a significant difference among the three groups ( p < 0.0167). CONCLUSION: Preemptive use of flurbiprofen axetil 1 mg/kg combined with RB is an optimal choice for multimodal analgesia for day-care patients undergoing orbital implantation in terms of efficient acute pain control, without impeding patient-enhanced recovery.


Subject(s)
Analgesia , Nalbuphine , Humans , Nalbuphine/therapeutic use , Ambulatory Surgical Procedures , Acetaminophen/therapeutic use , Prospective Studies , Pain, Postoperative/prevention & control , Double-Blind Method
SELECTION OF CITATIONS
SEARCH DETAIL
...