1.
Surg Technol Int ; 24: 249-52, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24700227

ABSTRACT

The purpose of this study is to compare the anatomical outcome of robotic sacrocolpopexy for pelvic organ prolapse in women with a body mass index (BMI) of 30 and higher to those with a BMI under 30. This is a retrospective chart review. POP-Q measurements preoperatively and 12 months postoperatively were evaluated using non-parametric statistical analysis. The primary outcome was to compare postoperative POPQ measurements at 12 months following surgery. Secondary outcomes were age at the time of surgery, mesh erosion rate, blood loss, length of hospital stay, and baseline anatomical support. A total of 71 patients were identified: 44 patients had a BMI below 30, and 27 had a BMI equal to or greater than 30. We found no significant relationship between BMI and anatomical support at 12 months post operation. However, obese patients were younger at the time of prolapse surgery (53.6 versus 60.6 years of age, p=0.0022). In regards to the ICS prolapse stage, no difference was found between obese and non-obese patients (2.81 versus 2.95, p=0.17).


Subject(s)
Pelvic Organ Prolapse/physiopathology , Pelvic Organ Prolapse/surgery , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/statistics & numerical data , Body Mass Index , Female , Humans , Middle Aged , Obesity/complications , Pelvic Organ Prolapse/complications , Retrospective Studies
2.
Int Urogynecol J ; 25(5): 651-6, 2014 May.
Article in English | MEDLINE | ID: mdl-24297064

ABSTRACT

INTRODUCTION AND HYPOTHESIS: To evaluate the effect of surgical instruments handling on polypropylene mesh using scanning electron microscopy (SEM). METHODS: We applied different surgical instruments, including a few robotic ones, to pieces of polypropylene mesh. SEM was used to evaluate the morphological changes with this intervention. RESULTS: Straight hemostat, laparoscopic atraumatic grasper, laparoscopic needle driver, and robotic instruments (Bipolar forceps, Cadiere forceps, PK dissecting forceps and SutureCut) were applied to the mesh. SEM images of tool-affected mesh regions in specimens handled by different instruments along with the images of intact mesh were obtained. Average mesh fiber diameters, as well as the average parameters characterizing instrument-affected regions, were measured. There was substantial widening of the fibers in specimens handled by hemostat or a needle holder. An elliptical but much longer and narrower tool marking with more surface roughness was observed in mesh handled by a grasper. A ∼25-µm-wide and ∼200-µm-long strap was split on one side from the core of the fiber caused by Cadiere. CONCLUSIONS: There are morphological changes to polypropylene mesh caused by instrument handling. These changes are different depending on the instrument used. These alterations vary from changes in the surface creating roughness of the fiber, compression of the mesh with narrowing of the fiber in at least one direction or actual splitting or pitting of the fiber. Since there are no data regarding the effect of these morphological changes to the ultimate functioning of the mesh, surgeons should minimize mesh handling by instruments.


Subject(s)
Polypropylenes , Surface Properties , Surgical Instruments , Surgical Mesh , Humans , Microscopy, Electron, Scanning , Pelvic Organ Prolapse/surgery , Urinary Incontinence, Stress/surgery