Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Mol Cell Proteomics ; 10(7): M111.007666, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21532008

ABSTRACT

The unambiguous assignment of tandem mass spectra (MS/MS) to peptide sequences remains a key unsolved problem in proteomics. Spectral library search strategies have emerged as a promising alternative for peptide identification, in which MS/MS spectra are directly compared against a reference library of confidently assigned spectra. Two problems relate to library size. First, reference spectral libraries are limited to rediscovery of previously identified peptides and are not applicable to new peptides, because of their incomplete coverage of the human proteome. Second, problems arise when searching a spectral library the size of the entire human proteome. We observed that traditional dot product scoring methods do not scale well with spectral library size, showing reduction in sensitivity when library size is increased. We show that this problem can be addressed by optimizing scoring metrics for spectrum-to-spectrum searches with large spectral libraries. MS/MS spectra for the 1.3 million predicted tryptic peptides in the human proteome are simulated using a kinetic fragmentation model (MassAnalyzer version2.1) to create a proteome-wide simulated spectral library. Searches of the simulated library increase MS/MS assignments by 24% compared with Mascot, when using probabilistic and rank based scoring methods. The proteome-wide coverage of the simulated library leads to 11% increase in unique peptide assignments, compared with parallel searches of a reference spectral library. Further improvement is attained when reference spectra and simulated spectra are combined into a hybrid spectral library, yielding 52% increased MS/MS assignments compared with Mascot searches. Our study demonstrates the advantages of using probabilistic and rank based scores to improve performance of spectrum-to-spectrum search strategies.


Subject(s)
Data Interpretation, Statistical , Peptide Fragments/analysis , Peptide Library , Peptide Mapping/methods , Proteome/analysis , Algorithms , Humans , Probability , ROC Curve , Reference Values , Tandem Mass Spectrometry
2.
Mol Cell ; 34(1): 115-31, 2009 Apr 10.
Article in English | MEDLINE | ID: mdl-19362540

ABSTRACT

Melanoma and other cancers harbor oncogenic mutations in the protein kinase B-Raf, which leads to constitutive activation and dysregulation of MAP kinase signaling. In order to elucidate molecular determinants responsible for B-Raf control of cancer phenotypes, we present a method for phosphoprotein profiling, using negative ionization mass spectrometry to detect phosphopeptides based on their fragment ion signature caused by release of PO(3)(-). The method provides an alternative strategy for phosphoproteomics, circumventing affinity enrichment of phosphopeptides and isotopic labeling of samples. Ninety phosphorylation events were regulated by oncogenic B-Raf signaling, based on their responses to treating melanoma cells with MKK1/2 inhibitor. Regulated phosphoproteins included known signaling effectors and cytoskeletal regulators. We investigated MINERVA/FAM129B, a target belonging to a protein family with unknown category and function, and established the importance of this protein and its MAP kinase-dependent phosphorylation in controlling melanoma cell invasion into three-dimensional collagen matrix.


Subject(s)
Melanoma/metabolism , Proteomics , Proto-Oncogene Proteins B-raf/metabolism , Cell Line, Tumor , Humans , MAP Kinase Signaling System , Mass Spectrometry , Mutation , Phosphoproteins/analysis , Phosphoproteins/chemistry , Phosphoproteins/genetics , Phosphoproteins/metabolism , Phosphoproteins/physiology , Phosphorylation , Proto-Oncogene Proteins B-raf/genetics , Proto-Oncogene Proteins B-raf/physiology , Substrate Specificity
3.
Mol Cell Proteomics ; 8(4): 857-69, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19106086

ABSTRACT

Identifying peptides from mass spectrometric fragmentation data (MS/MS spectra) using search strategies that map protein sequences to spectra is computationally expensive. An alternative strategy uses direct spectrum-to-spectrum matching against a reference library of previously observed MS/MS that has the advantage of evaluating matches using fragment ion intensities and other ion types than the simple set normally used. However, this approach is limited by the small sizes of the available peptide MS/MS libraries and the inability to evaluate the rate of false assignments. In this study, we observed good performance of simulated spectra generated by the kinetic model implemented in MassAnalyzer (Zhang, Z. (2004) Prediction of low-energy collision-induced dissociation spectra of peptides. Anal. Chem. 76, 3908-3922; Zhang, Z. (2005) Prediction of low-energy collision-induced dissociation spectra of peptides with three or more charges. Anal. Chem. 77, 6364-6373) as a substitute for the reference libraries used by the spectrum-to-spectrum search programs X!Hunter and BiblioSpec and similar results in comparison with the spectrum-to-sequence program Mascot. We also demonstrate the use of simulated spectra for searching against decoy sequences to estimate false discovery rates. Although we found lower score discrimination with spectrum-to-spectrum searches than with Mascot, particularly for higher charge forms, comparable peptide assignments with low false discovery rate were achieved by examining consensus between X!Hunter and Mascot, filtering results by mass accuracy, and ignoring score thresholds. Protein identification results are comparable to those achieved when evaluating consensus between Sequest and Mascot. Run times with large scale data sets using X!Hunter with the simulated spectral library are 7 times faster than Mascot and 80 times faster than Sequest with the human International Protein Index (IPI) database. We conclude that simulated spectral libraries greatly expand the search space available for spectrum-to-spectrum searching while enabling principled analyses and that the approach can be used in consensus strategies for large scale studies while reducing search times.


Subject(s)
Computer Simulation , Mass Spectrometry , Peptide Library , Proteins/analysis , Amino Acid Sequence , Cell Line, Tumor , Databases, Protein , Humans , Peptides/chemistry , Proteins/chemistry , ROC Curve , Reference Standards , Software
4.
Mol Cell Proteomics ; 6(1): 1-17, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17018520

ABSTRACT

A major limitation in identifying peptides from complex mixtures by shotgun proteomics is the ability of search programs to accurately assign peptide sequences using mass spectrometric fragmentation spectra (MS/MS spectra). Manual analysis is used to assess borderline identifications; however, it is error-prone and time-consuming, and criteria for acceptance or rejection are not well defined. Here we report a Manual Analysis Emulator (MAE) program that evaluates results from search programs by implementing two commonly used criteria: 1) consistency of fragment ion intensities with predicted gas phase chemistry and 2) whether a high proportion of the ion intensity (proportion of ion current (PIC)) in the MS/MS spectra can be derived from the peptide sequence. To evaluate chemical plausibility, MAE utilizes similarity (Sim) scoring against theoretical spectra simulated by MassAnalyzer software (Zhang, Z. (2004) Prediction of low-energy collision-induced dissociation spectra of peptides. Anal. Chem. 76, 3908-3922) using known gas phase chemical mechanisms. The results show that Sim scores provide significantly greater discrimination between correct and incorrect search results than achieved by Sequest XCorr scoring or Mascot Mowse scoring, allowing reliable automated validation of borderline cases. To evaluate PIC, MAE simplifies the DTA text files summarizing the MS/MS spectra and applies heuristic rules to classify the fragment ions. MAE output also provides data mining functions, which are illustrated by using PIC to identify spectral chimeras, where two or more peptide ions were sequenced together, as well as cases where fragmentation chemistry is not well predicted.


Subject(s)
Mass Spectrometry/methods , Peptides/analysis , Peptides/chemistry , Amino Acid Sequence , Databases, Protein , Humans , K562 Cells , Molecular Sequence Data , Neoplasm Proteins/chemistry , Protein Array Analysis , Proteomics , ROC Curve , Reproducibility of Results , Software
5.
Anal Chem ; 78(4): 1071-84, 2006 Feb 15.
Article in English | MEDLINE | ID: mdl-16478097

ABSTRACT

Correct identification of a peptide sequence from MS/MS data is still a challenging research problem, particularly in proteomic analyses of higher eukaryotes where protein databases are large. The scoring methods of search programs often generate cases where incorrect peptide sequences score higher than correct peptide sequences (referred to as distraction). Because smaller databases yield less distraction and better discrimination between correct and incorrect assignments, we developed a method for editing a peptide-centric database (PC-DB) to remove unlikely sequences and strategies for enabling search programs to utilize this peptide database. Rules for unlikely missed cleavage and nontryptic proteolysis products were identified by data mining 11 849 high-confidence peptide assignments. We also evaluated ion exchange chromatographic behavior as an editing criterion to generate subset databases. When used to search a well-annotated test data set of MS/MS spectra, we found no loss of critical information using PC-DBs, validating the methods for generating and searching against the databases. On the other hand, improved confidence in peptide assignments was achieved for tryptic peptides, measured by changes in DeltaCN and RSP. Decreased distraction was also achieved, consistent with the 3-9-fold decrease in database size. Data mining identified a major class of common nonspecific proteolytic products corresponding to leucine aminopeptidase (LAP) cleavages. Large improvements in identifying LAP products were achieved using the PC-DB approach when compared with conventional searches against protein databases. These results demonstrate that peptide properties can be used to reduce database size, yielding improved accuracy and information capture due to reduced distraction, but with little loss of information compared to conventional protein database searches.


Subject(s)
Databases, Protein , Information Storage and Retrieval , Peptide Hydrolases/metabolism , Peptides/chemistry , Proteomics , Amino Acid Sequence , Humans , Hydrolysis , Mass Spectrometry , Molecular Sequence Data , Sensitivity and Specificity
7.
Anal Chem ; 76(6): 1683-9, 2004 Mar 15.
Article in English | MEDLINE | ID: mdl-15018568

ABSTRACT

We have developed a novel method for quantifying protein isoforms, in both relative and absolute terms, based on MALDI-TOF mass spectrometry. The utility of the approach is demonstrated by quantifying the alpha and beta protein isoforms of myosin heavy chain (MyHC) in human atrial tissue. Alpha-MyHC (726-741) and beta-MyHC (724-739) were identified as isoform-specific tryptic peptides. A calibration curve was constructed by plotting ion current ratios against molar ratios of the two peptides prepared synthetically. MyHC was digested by trypsin and the ion current ratio determined for the two tryptic peptides. The ion current ratio was converted to the peptide ratio and hence the isoform ratio by reference to the standard curve. The accuracy of the method was confirmed by a comparison between these results and those determined by an established method of MyHC isoform ratio determination. So that the molar ratio could be converted to absolute values, a third peptide, an analogue of the two peptides being measured, was synthesized for use as an internal standard (IS). The measured ion current ratios of synthetic alpha-MyHC (726-741), beta-MyHC (724-739), and IS peptides were used to generate standard curves. A known quantity of the IS was added to the MyHC digests. The measured ion current ratios were converted to the actual quantities of the isoform-specific peptides and hence the actual quantity of each protein isoform by reference to the standard curves. This method is of general applicability, especially when isoform quantification is required.


Subject(s)
Myocardium/chemistry , Myosin Heavy Chains/analysis , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Humans , Myosin Heavy Chains/chemistry , Peptides/analysis , Peptides/chemistry , Protein Isoforms/analysis , Protein Isoforms/chemistry , Ventricular Myosins/analysis , Ventricular Myosins/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...