Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
BMC Infect Dis ; 23(1): 315, 2023 May 10.
Article in English | MEDLINE | ID: mdl-37165323

ABSTRACT

BACKGROUND: As the Human Immunodeficiency Virus (HIV) rapid testing services expanded to reach the global target that 95% of people living with the virus will know their status by 2030, ensuring the quality of those services becomes critical. This study was conducted to assess the performance of HIV Rapid testing at sites in health facilities that were enrolled in the Rapid Test Quality Improvement Initiative (RTQII) in Ethiopia. METHODS: Characterized HIV proficiency testing (PT) panels of Dried Tube Specimen (DTS) were prepared, verified, and distributed to testing sites from August to December 2019. In addition on-site evaluation of HIV testing sites (HTSs) was conducted using a checklist to assess testing conditions. For proficiency testing, the study included 159 HIV testing sites (HTSs) in 41 Health facilities (HFs) in five administrative regions and two city administrations. The collected data was analyzed by SPSS version 20 and chi-square test was applied to identify the association between acceptable performance and contributing factors. Testing sites with 100% PT score as well as conducting the test with adherence to the National HIV Testing Algorithm were considered acceptable. RESULTS: The overall acceptable performance (100% PT score with the correct algorithm followed) was found to be 62% while 12% scored 80% and 11% scored between 20 and 60%. The rest 15% were not considered as acceptable due to failure to adhere to the National HIV Testing Algorithm. Testing sites that participated in External Quality Assessment/Proficiency Testing schemes have shown better performance than those that did not participate with 70% and 56% performance respectively (p = 0.057).


Subject(s)
HIV Infections , Humans , HIV Infections/diagnosis , Ethiopia , Quality Improvement , HIV Testing , Health Facilities
2.
BMC Chem ; 16(1): 87, 2022 Nov 05.
Article in English | MEDLINE | ID: mdl-36335377

ABSTRACT

Honey is a natural, sugary and sticky liquid that is produced from the nectars of flowers by the bees. This study aimed to analyze the concentration of some selected heavy Metals in honey samples. 1 g of honey sample was digested by a hot plate using 9ml of HNO3 and 3ml of H2O2. The concentrations of the heavy metals in the digested were detected using a flame atomic absorption spectrometer. The results of this study found that the concentrations of the heavy metals in the honey samples were ranged from 1.97 to 2.04 µg/g for Zn, 1.93 µg/g to 2 µg/g for Cu, 0.83 to 1.01 µg/g for Mn, 0.25 to 0.45 µg/g for Cr, 0.025-0.031 µg/g for Cd. However, Pb was not detected in all honey samples. Hence, the levels of heavy metals found were below the permitted levels set by the World Health Organization. From the results, the levels of heavy metals found were below the permitted levels set by the World Health Organization. Thus, the heavy metals in the sampled honey are safe for human consumption in these selected areas.

3.
BMC Chem ; 16(1): 67, 2022 Sep 15.
Article in English | MEDLINE | ID: mdl-36109785

ABSTRACT

Nowadays, there are more than fourteen major state and private owned textile industries and garment factories in Ethiopia. However, these textile effluents are directly discharged without treatment to the surrounding environment, as a result, the pollutants bring serious problem to the surrounding community including health such as skin diseases, asthma, abortion, carcinogenic effect, biodiversity loss and mutagenic effect on the. The main objective of this study is characterization and treatment of the textile effluent using aluminum electrodes in the electrocoagulation process. EC experimental setups were designed and different parameters were optimized. Electrocoagulation treatment process eliminates physicochemical quality indicators such as pH, electrical conductivity (EC); turbidity, biological oxygen demand (BOD), ammonia; nitrate, nitrite, total nitrogen (TN) and phosphate were determined using standard procedures. From the result, the maximum removal efficiency of phosphate, ammonia, TN, electrical conductivity, turbidity and BOD were obtained 97, 87, 88, 89, 99 and 66%, respectively. Analyses of the electrochemically generated sludge by X-ray Diffraction, Scanning Electron Microscope (SEM), and Fourier Transform Infrared Spectroscopy (FTIR) revealed that the expected crystalline aluminum oxides (bayerite (Al(OH)3 diaspore (AlO(OH)) were found in the sludge. The amorphous phase was also found in the floc. Therefore, a treatment technology was good and encourages the community to apply the technique for the treatment of textile effluent before discharging into the environment.

4.
Malar J ; 20(1): 115, 2021 Feb 25.
Article in English | MEDLINE | ID: mdl-33632208

ABSTRACT

BACKGROUND: In Ethiopia, malaria cases are declining as a result of proven interventions, and in 2017 the country launched a malaria elimination strategy in targeted settings. Accurate malaria diagnosis and prompt treatment are the key components of the strategy to prevent morbidity and stop the continuation of transmission. However, the quality of microscopic diagnosis in general is deteriorating as malaria burden declines. This study was carried out to evaluate the competency of microscopists and the performance of health facilities on malaria microscopic diagnosis. METHODS: A cross-sectional study was conducted from 1 August to 30 September, 2019 in 9 regional states and one city administration. A standard checklist was used for on-site evaluation, archived patient slides were re-checked and proficiency of microscopists was tested using a WHO-certified set of slides from the national slide bank at the Ethiopian Public Health Institute (EPHI). The strength of agreement, sensitivity, specificity, and positive and negative predictive values were calculated. RESULTS: In this study, 102 health facilities (84 health centres and 18 hospitals) were included, from which 202 laboratory professionals participated. In slide re-checking, moderate agreement (agreement (A): 76.0%; Kappa (K): 0.41) was observed between experts and microscopists on malaria detection in all health facilities. The sensitivity and specificity of routine slide reading and the re-checking results were 78.1 and 80.7%, respectively. Likewise, positive predictive value of 65.1% and negative predictive value of 88.8% were scored in the routine diagnosis. By panel testing, a substantial overall agreement (A: 91.8%; K: 0.79) was observed between microscopists and experts in detecting malaria parasites. The sensitivity and specificity in the detection of malaria parasites was 92.7 and 89.1%, respectively. In identifying species, a slight agreement (A: 57%; K: 0.18) was observed between microscopists and experts. CONCLUSION: The study found significant false positive and false negative results in routine microscopy on slide re-checking of Plasmodium parasites. Moreover, reduced grade in parasite species identification was reported on the panel tests. Implementing comprehensive malaria microscopy mentorship, in-service training and supportive supervision are key strategies to improve the overall performance of health facilities in malaria microscopy.


Subject(s)
Diagnostic Services/statistics & numerical data , Diagnostic Tests, Routine/statistics & numerical data , Health Facilities/statistics & numerical data , Malaria/diagnosis , Mentors/statistics & numerical data , Microscopy/statistics & numerical data , Professional Competence/statistics & numerical data , Adult , Cross-Sectional Studies , Ethiopia , Female , Humans , Male , Middle Aged , Sensitivity and Specificity , Young Adult
5.
BMC Health Serv Res ; 20(1): 13, 2020 Jan 03.
Article in English | MEDLINE | ID: mdl-31900148

ABSTRACT

BACKGROUND: Knowing customers' level of satisfaction is relevant to improve and provide quality health care services. In the clinical laboratory, monitoring customers' satisfaction is an important indicator of the quality management system and required by international laboratory standards. However, in Ethiopia, there has not been baseline data about the satisfaction level of patients' with laboratory services at the national level. The aim of this national level survey was to assess patients' satisfaction level with laboratory services at public hospitals in Ethiopia. METHODS: A national survey was conducted using an institutional based cross-sectional study design was employed from 01 to 30 November 2017. A total of 2399 patients were selected randomly from 60 public hospitals. Data was collected using structured questionnaire, entered in Epi Info and analyzed with SPSS software. Multiple logistic regression model was fitted to identify predictors of patients' satisfaction with laboratory services. A p-value of less than 0.05 was taken as statistically significant. RESULT: Overall, 78.6% of the patients were satisfied with the clinical laboratory services. Patients were dissatisfied with cleanness of latrine (47%), long waiting time (30%), clear and understandable advisory service during specimen collection (26%), adequacy of waiting area (25%), easy accessibility of laboratory (19%) and latrine location (20%), availability of requested service (18%), unfair payment of service (17%) and missing of result (12%). The educational status (P = 0.032), and distance (P = 0.000) were significantly associated with client overall satisfaction level. CONCLUSION: Most laboratory patients' were satisfied with the service provided by public hospital laboratories in public hospitals in Ethiopia. However, patients' were dissatisfied with the accessibility of sites, adequacy of waiting area, cleanness of latrine, long TAT, communication, missing of results, availability of requested service and cost of service. Therefore, responsible bodies in each level should act on the identified gaps and improve the need of patients in each hospital laboratory. In addition, all hospital laboratories should conduct a satisfaction survey and meet the needs of laboratory patients.


Subject(s)
Clinical Laboratory Services , Hospitals, Public , Laboratories, Hospital , Patient Satisfaction/statistics & numerical data , Adult , Cross-Sectional Studies , Ethiopia , Female , Humans , Male , Middle Aged , Surveys and Questionnaires
6.
Afr J Lab Med ; 6(1): 590, 2017.
Article in English | MEDLINE | ID: mdl-28879154

ABSTRACT

BACKGROUND: Tuberculosis is an infectious disease caused by the bacillus Mycobacterium tuberculosis. According to the Ethiopian Federal Ministry of Health's 2013-2014 report, the tuberculosis case detection rate was 53.7%, which was below the target of 81% set for that year. OBJECTIVE: This study assessed the performance of tuberculosis smear microscopists at external quality assessment rechecking laboratories in Ethiopia. METHODS: A cross-sectional study was conducted at 81 laboratories from April to July 2015. Panel slides were prepared and validated at the National Tuberculosis Reference Laboratory. The validated panel slides were used to evaluate the performance of microscopists at these laboratories compared with readers from the reference laboratory. RESULTS: A total of 389 external quality assessment rechecking laboratory microscopists participated in the study, of which 268 (68.9%) worked at hospitals, 241 (62%) had more than five years of work experience, 201 (51.7%) held Bachelors degrees, and 319 (82%) reported tuberculosis smear microscopy training. Overall, 324 (83.3%) participants scored ≥ 80%. Sensitivity for detecting tuberculosis bacilli was 84.5% and specificity was 93.1%. The overall percent agreement between participants and reference readers was 87.1 (kappa=0.72). All 10 slides were correctly read (i.e., scored 100%) by 80 (20.6%) participants, 156 (40.1%) scored 90% - 95%, 88 (22.6%) scored 80% - 85% and 65 (16.7%) scored below 80%. There were 806 (20.7%) total errors, with 143 (3.7%) major and 663 (17%) minor errors. CONCLUSION: The overall performance of participants in reading the slides showed good agreement with the reference readers. Most errors were minor, and the ability to detect tuberculosis bacilli can be improved through building the capacity of professionals.

7.
Malariaworld J ; 8: 6, 2017.
Article in English | MEDLINE | ID: mdl-34532230

ABSTRACT

BACKGROUND: Microscopic diagnosis of Giemsa-stained thick and thin blood films has remained the standard laboratory method for diagnosing malaria. High quality performance of microscopists that examine blood slides in health facilities remains critically important. MATERIALS AND METHODS: A cross-sectional study was conducted to assess the performance of 107 malaria microscopists working at 23 malaria rechecking laboratories in Ethiopia. A set of 12 blood film slides was distributed to each microscopist. Data was collected and exported to SPSS version 20 for analysis. Chi-square, sensitivity, specificity, percent agreement, and kappa scores were calculated to assess performance in detecting and identification of Plasmodium species. RESULTS: The mean age of the participants was 30 ± 5 yrs and most of them (54; 50.5%) were working at regional reference laboratories. Overall, the sensitivity of participants in detecting and identifying malaria parasite species was 96.8% and 56.7%, respectively. The overall agreement on detection and identification of malaria species was 96.8% (Kappa = 0.9) and 64.8% (Kappa = 0.33), respectively. The least accurately identified malaria parasite species was P. malariae (3/107; 2.8%) followed by P. ovale (35/107; 32.7%). Participants working at hospital laboratories had the highest percentage (72.3 %, Kappa=0.51) of accurate species identification. Study participants that had participated in malaria microscopy and quality assurance trainings were significantly better at quantifying parasite densities (P<0.001). CONCLUSION: The accuracy of parasite identification and quantification differed strongly between participants and expert microscopists. Therefore, regular competency assessment and training for malaria microscopists should be mandatory to assure proper diagnosis and management of malaria in Ethiopia.

8.
Afr J Lab Med ; 3(2): 233, 2014.
Article in English | MEDLINE | ID: mdl-29043195

ABSTRACT

BACKGROUND: Strengthening Laboratory Management Toward Accreditation (SLMTA) is a competency-based management training programme. Assessing health professionals' views of SLMTA provides feedback to inform program planning, implementation and evaluation of SLMTA's training, communication and mentorship components. OBJECTIVES: To assess laboratory professionals' and hospital chief executive officers' (CEOs) perceptions and attitudes toward the SLMTA programme in Ethiopia. METHODS: A cross-sectional descriptive survey was conducted in March 2013 using a structured questionnaire to collect qualitative data from 72 laboratory professionals and hospital CEOs from 17 health facilities, representing all regions and two city administrations in Ethiopia. Focus groups were conducted with laboratory professionals and hospital administration to gain insight into the strengths and challenges of the SLMTA programme so as to guide future planning and implementation. RESULTS: Ethiopian laboratory professionals at all levels had a supportive attitude toward the SLMTA programme. They believed that SLMTA substantially improved laboratory services and acted as a catalyst for total healthcare reform and improvement. They also noted that the SLMTA programme achieved marked progress in laboratory supply chain, sample referral, instrument maintenance and data management systems. In contrast, nearly half of the participating hospital CEOs, especially those associated with low-scoring laboratories, were sceptical about the SLMTA programme, believing that the benefits of SLMTA were outweighed by the level of human resources and time commitment required. They also voiced concerns about the cost and sustainability of SLMTA. CONCLUSION: This study highlights the need for stronger engagement and advocacy with hospital administration and the importance of addressing concerns about the cost and sustainability of the SLMTA programme.

SELECTION OF CITATIONS
SEARCH DETAIL
...